Evaluation of Switching Power Amplifier Topology for Active Magnetic Bearings

Active magnetic bearings (AMBs) have led to great progress in the field of rotating machinery due to their many advantages, such as their non-contact and non-lubrication properties. As the key component of an AMB actuator, the switching power amplifier has an important impact on the performance of m...

Full description

Bibliographic Details
Main Authors: Kezhen Yang, Yefa Hu, Xinhua Guo, Jian Zhou, Huachun Wu
Format: Article
Language:English
Published: MDPI AG 2021-06-01
Series:Actuators
Subjects:
Online Access:https://www.mdpi.com/2076-0825/10/6/131
_version_ 1797530280306671616
author Kezhen Yang
Yefa Hu
Xinhua Guo
Jian Zhou
Huachun Wu
author_facet Kezhen Yang
Yefa Hu
Xinhua Guo
Jian Zhou
Huachun Wu
author_sort Kezhen Yang
collection DOAJ
description Active magnetic bearings (AMBs) have led to great progress in the field of rotating machinery due to their many advantages, such as their non-contact and non-lubrication properties. As the key component of an AMB actuator, the switching power amplifier has an important impact on the performance of magnetic bearings and rotating machinery. In this paper, the topologies of switching power amplifiers for AMBs are introduced. The traditional half-bridge topology and two newly proposed topologies—the three-phase-half-bridge and neutralized-sharing-bridge topology—are analyzed and discussed. The volume, current output performance and cost of the power amplifier with different topologies are comprehensively evaluated, providing a theoretical basis and guidance for the selection and design of the topology of switching power amplifiers for AMBs under different conditions.
first_indexed 2024-03-10T10:26:47Z
format Article
id doaj.art-dfbd08ce3cdc4baf9f29d02ad0713c79
institution Directory Open Access Journal
issn 2076-0825
language English
last_indexed 2024-03-10T10:26:47Z
publishDate 2021-06-01
publisher MDPI AG
record_format Article
series Actuators
spelling doaj.art-dfbd08ce3cdc4baf9f29d02ad0713c792023-11-21T23:57:54ZengMDPI AGActuators2076-08252021-06-0110613110.3390/act10060131Evaluation of Switching Power Amplifier Topology for Active Magnetic BearingsKezhen Yang0Yefa Hu1Xinhua Guo2Jian Zhou3Huachun Wu4School of Mechanical & Electronic Engineering, Wuhan University of Technology, Wuhan 430070, ChinaHubei Provincial Engineering Technology Research Center for Magnetic Suspension, School of Mechanical & Electronic Engineering, Wuhan University of Technology, Wuhan 430070, ChinaHubei Provincial Engineering Technology Research Center for Magnetic Suspension, School of Mechanical & Electronic Engineering, Wuhan University of Technology, Wuhan 430070, ChinaSchool of Mechanical & Electronic Engineering, Wuhan University of Technology, Wuhan 430070, ChinaHubei Provincial Engineering Technology Research Center for Magnetic Suspension, School of Mechanical & Electronic Engineering, Wuhan University of Technology, Wuhan 430070, ChinaActive magnetic bearings (AMBs) have led to great progress in the field of rotating machinery due to their many advantages, such as their non-contact and non-lubrication properties. As the key component of an AMB actuator, the switching power amplifier has an important impact on the performance of magnetic bearings and rotating machinery. In this paper, the topologies of switching power amplifiers for AMBs are introduced. The traditional half-bridge topology and two newly proposed topologies—the three-phase-half-bridge and neutralized-sharing-bridge topology—are analyzed and discussed. The volume, current output performance and cost of the power amplifier with different topologies are comprehensively evaluated, providing a theoretical basis and guidance for the selection and design of the topology of switching power amplifiers for AMBs under different conditions.https://www.mdpi.com/2076-0825/10/6/131electromagnetic actuatorsactive magnetic bearingsswitching power amplifiertopology
spellingShingle Kezhen Yang
Yefa Hu
Xinhua Guo
Jian Zhou
Huachun Wu
Evaluation of Switching Power Amplifier Topology for Active Magnetic Bearings
Actuators
electromagnetic actuators
active magnetic bearings
switching power amplifier
topology
title Evaluation of Switching Power Amplifier Topology for Active Magnetic Bearings
title_full Evaluation of Switching Power Amplifier Topology for Active Magnetic Bearings
title_fullStr Evaluation of Switching Power Amplifier Topology for Active Magnetic Bearings
title_full_unstemmed Evaluation of Switching Power Amplifier Topology for Active Magnetic Bearings
title_short Evaluation of Switching Power Amplifier Topology for Active Magnetic Bearings
title_sort evaluation of switching power amplifier topology for active magnetic bearings
topic electromagnetic actuators
active magnetic bearings
switching power amplifier
topology
url https://www.mdpi.com/2076-0825/10/6/131
work_keys_str_mv AT kezhenyang evaluationofswitchingpoweramplifiertopologyforactivemagneticbearings
AT yefahu evaluationofswitchingpoweramplifiertopologyforactivemagneticbearings
AT xinhuaguo evaluationofswitchingpoweramplifiertopologyforactivemagneticbearings
AT jianzhou evaluationofswitchingpoweramplifiertopologyforactivemagneticbearings
AT huachunwu evaluationofswitchingpoweramplifiertopologyforactivemagneticbearings