Clinically relevant differences in the selection of toric intraocular lens power in normal eyes: preoperative measurement vs intraoperative aberrometry

James A Davison,1 Sarah Makari,2 Richard Potvin21Wolfe Eye Clinic, Marshalltown, IA, USA; 2Science in Vision, Akron, NY, USAPurpose: To assess the value of intraoperative aberrometry (IA) in determining toric intraocular lens (IOL) power in eyes with no previous ocular surgery.Patients and methods:...

Full description

Bibliographic Details
Main Authors: Davison JA, Makari S, Potvin R
Format: Article
Language:English
Published: Dove Medical Press 2019-05-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/clinically-relevant-differences-in-the-selection-of-toric-intraocular--peer-reviewed-article-OPTH
_version_ 1818399259356037120
author Davison JA
Makari S
Potvin R
author_facet Davison JA
Makari S
Potvin R
author_sort Davison JA
collection DOAJ
description James A Davison,1 Sarah Makari,2 Richard Potvin21Wolfe Eye Clinic, Marshalltown, IA, USA; 2Science in Vision, Akron, NY, USAPurpose: To assess the value of intraoperative aberrometry (IA) in determining toric intraocular lens (IOL) power in eyes with no previous ocular surgery.Patients and methods: This was a retrospective data review at one US clinical site of eyes that underwent uncomplicated cataract surgery with toric IOL implantation where standard preoperative and IA measurements were available. Calculated IOL sphere and cylinder powers and orientation were compared based on the measurement method and the postoperative refraction, using both actual and simulated (back-calculated) results. Comparisons were between the surgeon’s preoperative calculations, IA measurements, the actual IOL implanted and results from the Barrett toric calculator.Results: There was no significant difference (p>0.7) in the number of eyes expected to have, or having, a spherical equivalent refraction within 0.50D of the target between Actual (92%), IA (93%) or Preoperative calculation results (86%). The percentage of eyes with expected residual refractive astigmatism ≤0.50D was significantly higher for the IA vs Preoperative calculations (75% vs 53%, p<0.01). There was no significant difference in expected results between the Actual, IA and Barrett toric calculations (p>0.65).Conclusion: Modern IOL calculations for sphere produced results comparable to those achieved with IA. The value of IA in determining IOL cylinder power and orientation was more evident when comparing expected results between IA and a preoperative method based on measured total corneal astigmatism than when comparing to expected results from the Barrett toric calculator.Keywords: ORA, refraction, prediction error, IOL power calculation, astigmatism, toric IOL
first_indexed 2024-12-14T07:17:50Z
format Article
id doaj.art-dfdbbe40daa84f519b3560169b2b0abc
institution Directory Open Access Journal
issn 1177-5483
language English
last_indexed 2024-12-14T07:17:50Z
publishDate 2019-05-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj.art-dfdbbe40daa84f519b3560169b2b0abc2022-12-21T23:11:41ZengDove Medical PressClinical Ophthalmology1177-54832019-05-01Volume 1391392046176Clinically relevant differences in the selection of toric intraocular lens power in normal eyes: preoperative measurement vs intraoperative aberrometryDavison JAMakari SPotvin RJames A Davison,1 Sarah Makari,2 Richard Potvin21Wolfe Eye Clinic, Marshalltown, IA, USA; 2Science in Vision, Akron, NY, USAPurpose: To assess the value of intraoperative aberrometry (IA) in determining toric intraocular lens (IOL) power in eyes with no previous ocular surgery.Patients and methods: This was a retrospective data review at one US clinical site of eyes that underwent uncomplicated cataract surgery with toric IOL implantation where standard preoperative and IA measurements were available. Calculated IOL sphere and cylinder powers and orientation were compared based on the measurement method and the postoperative refraction, using both actual and simulated (back-calculated) results. Comparisons were between the surgeon’s preoperative calculations, IA measurements, the actual IOL implanted and results from the Barrett toric calculator.Results: There was no significant difference (p>0.7) in the number of eyes expected to have, or having, a spherical equivalent refraction within 0.50D of the target between Actual (92%), IA (93%) or Preoperative calculation results (86%). The percentage of eyes with expected residual refractive astigmatism ≤0.50D was significantly higher for the IA vs Preoperative calculations (75% vs 53%, p<0.01). There was no significant difference in expected results between the Actual, IA and Barrett toric calculations (p>0.65).Conclusion: Modern IOL calculations for sphere produced results comparable to those achieved with IA. The value of IA in determining IOL cylinder power and orientation was more evident when comparing expected results between IA and a preoperative method based on measured total corneal astigmatism than when comparing to expected results from the Barrett toric calculator.Keywords: ORA, refraction, prediction error, IOL power calculation, astigmatism, toric IOLhttps://www.dovepress.com/clinically-relevant-differences-in-the-selection-of-toric-intraocular--peer-reviewed-article-OPTHORArefractionprediction errorIOL power calculationastigmatismtoric IOL
spellingShingle Davison JA
Makari S
Potvin R
Clinically relevant differences in the selection of toric intraocular lens power in normal eyes: preoperative measurement vs intraoperative aberrometry
Clinical Ophthalmology
ORA
refraction
prediction error
IOL power calculation
astigmatism
toric IOL
title Clinically relevant differences in the selection of toric intraocular lens power in normal eyes: preoperative measurement vs intraoperative aberrometry
title_full Clinically relevant differences in the selection of toric intraocular lens power in normal eyes: preoperative measurement vs intraoperative aberrometry
title_fullStr Clinically relevant differences in the selection of toric intraocular lens power in normal eyes: preoperative measurement vs intraoperative aberrometry
title_full_unstemmed Clinically relevant differences in the selection of toric intraocular lens power in normal eyes: preoperative measurement vs intraoperative aberrometry
title_short Clinically relevant differences in the selection of toric intraocular lens power in normal eyes: preoperative measurement vs intraoperative aberrometry
title_sort clinically relevant differences in the selection of toric intraocular lens power in normal eyes preoperative measurement vs intraoperative aberrometry
topic ORA
refraction
prediction error
IOL power calculation
astigmatism
toric IOL
url https://www.dovepress.com/clinically-relevant-differences-in-the-selection-of-toric-intraocular--peer-reviewed-article-OPTH
work_keys_str_mv AT davisonja clinicallyrelevantdifferencesintheselectionoftoricintraocularlenspowerinnormaleyespreoperativemeasurementvsintraoperativeaberrometry
AT makaris clinicallyrelevantdifferencesintheselectionoftoricintraocularlenspowerinnormaleyespreoperativemeasurementvsintraoperativeaberrometry
AT potvinr clinicallyrelevantdifferencesintheselectionoftoricintraocularlenspowerinnormaleyespreoperativemeasurementvsintraoperativeaberrometry