Effect of Microimplant Neck Design with and without Microthread on Pullout Strength and Destruction Volume

The microthread neck concept has been applied to dental implants. This study investigated the pullout strength and destruction volume of orthodontic microimplants with and without the microthread neck design. Fifteen microimplants (diameter: 1.5 × 10 mm) of three types (Types A and B: without microi...

Full description

Bibliographic Details
Main Authors: Yu-Chuan Tseng, Han-Sheng Chen, Szu-Yu Hsiao, Kun-Jung Hsu, Chun-Ming Chen
Format: Article
Language:English
Published: MDPI AG 2021-10-01
Series:Materials
Subjects:
Online Access:https://www.mdpi.com/1996-1944/14/20/5991
_version_ 1797514069939322880
author Yu-Chuan Tseng
Han-Sheng Chen
Szu-Yu Hsiao
Kun-Jung Hsu
Chun-Ming Chen
author_facet Yu-Chuan Tseng
Han-Sheng Chen
Szu-Yu Hsiao
Kun-Jung Hsu
Chun-Ming Chen
author_sort Yu-Chuan Tseng
collection DOAJ
description The microthread neck concept has been applied to dental implants. This study investigated the pullout strength and destruction volume of orthodontic microimplants with and without the microthread neck design. Fifteen microimplants (diameter: 1.5 × 10 mm) of three types (Types A and B: without microimplant neck; Type C: with microimplant neck) were tested. The insertion torque (IT), Periotest value (PTV), horizontal pullout strength (HPS), and horizontal destruction volume (HDV) of each type were measured. Kruskal–Wallis H test and Dunn’s post-hoc comparison test were performed to compare the measured values of the three types of microimplants. The correlations of the measured values were used to perform the Spearman’s correlation coefficient analysis. The ITs of Types B (8.8 Ncm) and C (8.9 Ncm) were significantly higher than those of Type A (5.2 Ncm). Type B yielded the lowest PTV (4.1), and no statistical differences in PTV were observed among the three types. Type A had a significantly lower HPS (158.8 Ncm) than Types B (226.9 Ncm) and C (212.8 Ncm). The three types did not exhibit any significant differences in the HDV. The results of the Spearman’s correlation coefficient test revealed that HDV (ρ = 0.710) and IT (ρ = 0.813) were strongly correlated with HPS, whereas for PTV and HPS, it was not. HPS was strongly and significantly correlated with HDV. The orthodontic microimplant with a microimplant neck design did not perform better than that without a microthread in the mechanical strength test.
first_indexed 2024-03-10T06:26:25Z
format Article
id doaj.art-e025010090f542e4b503fb32eed302fc
institution Directory Open Access Journal
issn 1996-1944
language English
last_indexed 2024-03-10T06:26:25Z
publishDate 2021-10-01
publisher MDPI AG
record_format Article
series Materials
spelling doaj.art-e025010090f542e4b503fb32eed302fc2023-11-22T18:57:13ZengMDPI AGMaterials1996-19442021-10-011420599110.3390/ma14205991Effect of Microimplant Neck Design with and without Microthread on Pullout Strength and Destruction VolumeYu-Chuan Tseng0Han-Sheng Chen1Szu-Yu Hsiao2Kun-Jung Hsu3Chun-Ming Chen4School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807, TaiwanDepartment of Dentistry, Kaohsiung Municipal Siaogang Hospital, Kaohsiung 812, TaiwanSchool of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807, TaiwanSchool of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807, TaiwanSchool of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung 807, TaiwanThe microthread neck concept has been applied to dental implants. This study investigated the pullout strength and destruction volume of orthodontic microimplants with and without the microthread neck design. Fifteen microimplants (diameter: 1.5 × 10 mm) of three types (Types A and B: without microimplant neck; Type C: with microimplant neck) were tested. The insertion torque (IT), Periotest value (PTV), horizontal pullout strength (HPS), and horizontal destruction volume (HDV) of each type were measured. Kruskal–Wallis H test and Dunn’s post-hoc comparison test were performed to compare the measured values of the three types of microimplants. The correlations of the measured values were used to perform the Spearman’s correlation coefficient analysis. The ITs of Types B (8.8 Ncm) and C (8.9 Ncm) were significantly higher than those of Type A (5.2 Ncm). Type B yielded the lowest PTV (4.1), and no statistical differences in PTV were observed among the three types. Type A had a significantly lower HPS (158.8 Ncm) than Types B (226.9 Ncm) and C (212.8 Ncm). The three types did not exhibit any significant differences in the HDV. The results of the Spearman’s correlation coefficient test revealed that HDV (ρ = 0.710) and IT (ρ = 0.813) were strongly correlated with HPS, whereas for PTV and HPS, it was not. HPS was strongly and significantly correlated with HDV. The orthodontic microimplant with a microimplant neck design did not perform better than that without a microthread in the mechanical strength test.https://www.mdpi.com/1996-1944/14/20/5991microthread neckpullout strengthdestruction volumemicroimplant
spellingShingle Yu-Chuan Tseng
Han-Sheng Chen
Szu-Yu Hsiao
Kun-Jung Hsu
Chun-Ming Chen
Effect of Microimplant Neck Design with and without Microthread on Pullout Strength and Destruction Volume
Materials
microthread neck
pullout strength
destruction volume
microimplant
title Effect of Microimplant Neck Design with and without Microthread on Pullout Strength and Destruction Volume
title_full Effect of Microimplant Neck Design with and without Microthread on Pullout Strength and Destruction Volume
title_fullStr Effect of Microimplant Neck Design with and without Microthread on Pullout Strength and Destruction Volume
title_full_unstemmed Effect of Microimplant Neck Design with and without Microthread on Pullout Strength and Destruction Volume
title_short Effect of Microimplant Neck Design with and without Microthread on Pullout Strength and Destruction Volume
title_sort effect of microimplant neck design with and without microthread on pullout strength and destruction volume
topic microthread neck
pullout strength
destruction volume
microimplant
url https://www.mdpi.com/1996-1944/14/20/5991
work_keys_str_mv AT yuchuantseng effectofmicroimplantneckdesignwithandwithoutmicrothreadonpulloutstrengthanddestructionvolume
AT hanshengchen effectofmicroimplantneckdesignwithandwithoutmicrothreadonpulloutstrengthanddestructionvolume
AT szuyuhsiao effectofmicroimplantneckdesignwithandwithoutmicrothreadonpulloutstrengthanddestructionvolume
AT kunjunghsu effectofmicroimplantneckdesignwithandwithoutmicrothreadonpulloutstrengthanddestructionvolume
AT chunmingchen effectofmicroimplantneckdesignwithandwithoutmicrothreadonpulloutstrengthanddestructionvolume