Calculation of Start-Up Time of Passive Catalytic Hydrogen Recombiner of Localization Safety System of a Nuclear Power Plant Equipped with VVER
The hydrogen removal system ensures hydrogen safety. At a VVER nuclear power plant, it consists of passive catalytic hydrogen recombiners. The calculation of devices is of great importance for safety justification, since the complex conditions of an accident at a power unit are not reproducible in e...
Main Author: | V. V. Sorokin |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2022-02-01
|
Series: | Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika |
Subjects: | |
Online Access: | https://energy.bntu.by/jour/article/view/2133 |
Similar Items
-
Аnalysis Catalytic Hydrogen Recombiner Capacity Calculation Taking into Account Conditions Inside Sealed Enclosure of Containment Safety System of Nuclear Power Plants with Water-Water Energetic Reactor
by: V. V. Sorokin
Published: (2021-04-01) -
Prospects for the application of battery energy storage systems in NPP auxiliary power supply systems
by: V. V. Karchin, et al.
Published: (2023-10-01) -
Обеспечение пожарной безопасности водородных заправочных станций
by: Александр Викторович Фомин, et al.
Published: (2022-08-01) -
Energetics of Arab Countries in the Light of the Green Economy Challenges
by: V. A. Isaev, et al.
Published: (2022-07-01) -
Обеспечение пожарной безопасности атомных электростанций
by: Илья Жаворонков, et al.
Published: (2018-08-01)