The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques

Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI image...

Full description

Bibliographic Details
Main Authors: Farshidfar Z., Faeghi F., Haghighatkhah H. R., Abdolmohammadi J.
Format: Article
Language:English
Published: Shiraz University of Medical Sciences 2017-09-01
Series:Journal of Biomedical Physics and Engineering
Subjects:
Online Access:http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/559/357
_version_ 1818206798362968064
author Farshidfar Z.
Faeghi F.
Haghighatkhah H. R.
Abdolmohammadi J.
author_facet Farshidfar Z.
Faeghi F.
Haghighatkhah H. R.
Abdolmohammadi J.
author_sort Farshidfar Z.
collection DOAJ
description Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is evaluating the efficiency of different MRI sequences in order to better detection of MS plaques. Materials and methods: In this cross-sectional study which was performed at Shohada-E Tajrish in Tehran - Iran hospital between October, 2011 to April, 2012, included 20 patients who suspected to MS disease were selected by the method of random sampling and underwent routine brain Pulse sequences (Axial T2w, Axial T1w, Coronal T2w, Sagittal T1w, Axial FLAIR) by Siemens, Avanto, 1.5 Tesla system. If any lesion which is suspected to the MS disease was observed, additional sequences such as: Sagittal FLAIR Fat Sat, Sagittal PDw-fat Sat, Sagittal PDw-water sat was also performed. Results: This study was performed in about 52 lesions and the results in more than 19 lesions showed that, for the Subcortical and Infratentorial areas, PDWw sequence with fat suppression is the best choice, And in nearly 33 plaques located in Periventricular area, FLAIR Fat Sat was the most effective sequence than both PDw fat and water suppression pulse sequences. Conclusion: Although large plaques may visible in all images, but important problem in patients with suspected MS is screening the tiny MS plaques. This study showed that for revealing the MS plaques located in the Subcortical and Infratentorial areas, PDw-fat sat is the most effective sequence, and for MS plaques in the periventricular area, FLAIR fat Sat is the best choice.
first_indexed 2024-12-12T04:18:45Z
format Article
id doaj.art-e0fb2469beb24405920170226a19a446
institution Directory Open Access Journal
issn 2251-7200
2251-7200
language English
last_indexed 2024-12-12T04:18:45Z
publishDate 2017-09-01
publisher Shiraz University of Medical Sciences
record_format Article
series Journal of Biomedical Physics and Engineering
spelling doaj.art-e0fb2469beb24405920170226a19a4462022-12-22T00:38:23ZengShiraz University of Medical SciencesJournal of Biomedical Physics and Engineering2251-72002251-72002017-09-0173265270The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis PlaquesFarshidfar Z.0Faeghi F.1 Haghighatkhah H. R.2 Abdolmohammadi J.3MSc of Medical Imaging Technology (MRI), Radiology Department of Paramedical School, Shiraz University of Medical Sciences, Shiraz, Iran Ph.D. in Medical Physics, Radiology Technology Department, School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, IranMD, Department of Radiology, Shohada Tajrish Hospital, Shahid Beheshti University of medical sciences, Tehran, Iran MSc. of Medical Imaging Technology (MRI), Department of Radiology, Faculty of Paramedical Sciences, Kurdistan University of Medical Sciences, Sanandaj, IranBackground and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is evaluating the efficiency of different MRI sequences in order to better detection of MS plaques. Materials and methods: In this cross-sectional study which was performed at Shohada-E Tajrish in Tehran - Iran hospital between October, 2011 to April, 2012, included 20 patients who suspected to MS disease were selected by the method of random sampling and underwent routine brain Pulse sequences (Axial T2w, Axial T1w, Coronal T2w, Sagittal T1w, Axial FLAIR) by Siemens, Avanto, 1.5 Tesla system. If any lesion which is suspected to the MS disease was observed, additional sequences such as: Sagittal FLAIR Fat Sat, Sagittal PDw-fat Sat, Sagittal PDw-water sat was also performed. Results: This study was performed in about 52 lesions and the results in more than 19 lesions showed that, for the Subcortical and Infratentorial areas, PDWw sequence with fat suppression is the best choice, And in nearly 33 plaques located in Periventricular area, FLAIR Fat Sat was the most effective sequence than both PDw fat and water suppression pulse sequences. Conclusion: Although large plaques may visible in all images, but important problem in patients with suspected MS is screening the tiny MS plaques. This study showed that for revealing the MS plaques located in the Subcortical and Infratentorial areas, PDw-fat sat is the most effective sequence, and for MS plaques in the periventricular area, FLAIR fat Sat is the best choice.http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/559/357Multiple SclerosisMRIPDW fat suppressionPDW water suppressionFLAIR
spellingShingle Farshidfar Z.
Faeghi F.
Haghighatkhah H. R.
Abdolmohammadi J.
The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
Journal of Biomedical Physics and Engineering
Multiple Sclerosis
MRI
PDW fat suppression
PDW water suppression
FLAIR
title The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
title_full The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
title_fullStr The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
title_full_unstemmed The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
title_short The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
title_sort optimization of magnetic resonance imaging pulse sequences in order to better detection of multiple sclerosis plaques
topic Multiple Sclerosis
MRI
PDW fat suppression
PDW water suppression
FLAIR
url http://www.jbpe.org/Journal_OJS/JBPE/index.php/jbpe/article/view/559/357
work_keys_str_mv AT farshidfarz theoptimizationofmagneticresonanceimagingpulsesequencesinordertobetterdetectionofmultiplesclerosisplaques
AT faeghif theoptimizationofmagneticresonanceimagingpulsesequencesinordertobetterdetectionofmultiplesclerosisplaques
AT haghighatkhahhr theoptimizationofmagneticresonanceimagingpulsesequencesinordertobetterdetectionofmultiplesclerosisplaques
AT abdolmohammadij theoptimizationofmagneticresonanceimagingpulsesequencesinordertobetterdetectionofmultiplesclerosisplaques
AT farshidfarz optimizationofmagneticresonanceimagingpulsesequencesinordertobetterdetectionofmultiplesclerosisplaques
AT faeghif optimizationofmagneticresonanceimagingpulsesequencesinordertobetterdetectionofmultiplesclerosisplaques
AT haghighatkhahhr optimizationofmagneticresonanceimagingpulsesequencesinordertobetterdetectionofmultiplesclerosisplaques
AT abdolmohammadij optimizationofmagneticresonanceimagingpulsesequencesinordertobetterdetectionofmultiplesclerosisplaques