Numerical study of the effect of individual racks in lenses on the operation of nonlinear lenticular membrane-pneumatic systems by the step method

Objective. The purpose of this study is to substantiate the methodology for static calculation of light coatings for large-span structures with lenticular membrane-pneumatic lenses, including racks at individual points of the span, using the step-iterative method of parameter increments.Method. The...

Full description

Bibliographic Details
Main Authors: A. Yu. Kim, M. F. Amoyan, V. E. Khapilin
Format: Article
Language:Russian
Published: Dagestan State Technical University 2022-05-01
Series:Вестник Дагестанского государственного технического университета: Технические науки
Subjects:
Online Access:https://vestnik.dgtu.ru/jour/article/view/1046
_version_ 1797702393725452288
author A. Yu. Kim
M. F. Amoyan
V. E. Khapilin
author_facet A. Yu. Kim
M. F. Amoyan
V. E. Khapilin
author_sort A. Yu. Kim
collection DOAJ
description Objective. The purpose of this study is to substantiate the methodology for static calculation of light coatings for large-span structures with lenticular membrane-pneumatic lenses, including racks at individual points of the span, using the step-iterative method of parameter increments.Method. The study involves the phased application of the finite element method (FEM), the universal equation of state of gas and the improved Euler-Cauchy numerical procedure, taking into account the geometric nonlinearity of systems and the physical nonlinearity of the elastic work of air in lenses and taking into account the aftereffect of excess air pressure.Result. A comparison is made in terms of rigidity and load-bearing capacity of membrane-pneumatic lenses, reinforced with individual posts, with the corresponding flexible membrane-pneumatic lenses of the classical type.Conclusion. In the presence of racks, the effect of a significant increase in the rigidity and bearing capacity of lenticular membrane-pneumatic systems is observed for large spans. The distance between the posts along the building can be adjusted during the design and thereby regulate the effect of strengthening the system. The maximum deflections of the lenticular-shaped membrane-pneumatic system reinforced with struts are much less than the maximum deflections of the lenticular membrane-pneumatic system of the classical type under the action of the calculated snow load of the first and second limit states.
first_indexed 2024-03-12T04:50:21Z
format Article
id doaj.art-e1b2f51899d54c489151ac926fc87867
institution Directory Open Access Journal
issn 2073-6185
2542-095X
language Russian
last_indexed 2024-03-12T04:50:21Z
publishDate 2022-05-01
publisher Dagestan State Technical University
record_format Article
series Вестник Дагестанского государственного технического университета: Технические науки
spelling doaj.art-e1b2f51899d54c489151ac926fc878672023-09-03T09:26:27ZrusDagestan State Technical UniversityВестник Дагестанского государственного технического университета: Технические науки2073-61852542-095X2022-05-0149112213210.21822/2073-6185-2022-49-1-122-132688Numerical study of the effect of individual racks in lenses on the operation of nonlinear lenticular membrane-pneumatic systems by the step methodA. Yu. Kim0M. F. Amoyan1V. E. Khapilin2Саратовский государственный технический университет имени Гагарина Ю.А.Саратовский государственный технический университет имени Гагарина Ю.А.Саратовский государственный технический университет имени Гагарина Ю.А.Objective. The purpose of this study is to substantiate the methodology for static calculation of light coatings for large-span structures with lenticular membrane-pneumatic lenses, including racks at individual points of the span, using the step-iterative method of parameter increments.Method. The study involves the phased application of the finite element method (FEM), the universal equation of state of gas and the improved Euler-Cauchy numerical procedure, taking into account the geometric nonlinearity of systems and the physical nonlinearity of the elastic work of air in lenses and taking into account the aftereffect of excess air pressure.Result. A comparison is made in terms of rigidity and load-bearing capacity of membrane-pneumatic lenses, reinforced with individual posts, with the corresponding flexible membrane-pneumatic lenses of the classical type.Conclusion. In the presence of racks, the effect of a significant increase in the rigidity and bearing capacity of lenticular membrane-pneumatic systems is observed for large spans. The distance between the posts along the building can be adjusted during the design and thereby regulate the effect of strengthening the system. The maximum deflections of the lenticular-shaped membrane-pneumatic system reinforced with struts are much less than the maximum deflections of the lenticular membrane-pneumatic system of the classical type under the action of the calculated snow load of the first and second limit states.https://vestnik.dgtu.ru/jour/article/view/1046шагово - итерационный метод приращений параметровусовершенствованной численной процедуры эйлера-кошиучетом геометрической и физической нелинейности упругой свойств воздуха в пневмополостимембранно-пневматические линзы классического типа
spellingShingle A. Yu. Kim
M. F. Amoyan
V. E. Khapilin
Numerical study of the effect of individual racks in lenses on the operation of nonlinear lenticular membrane-pneumatic systems by the step method
Вестник Дагестанского государственного технического университета: Технические науки
шагово - итерационный метод приращений параметров
усовершенствованной численной процедуры эйлера-коши
учетом геометрической и физической нелинейности упругой свойств воздуха в пневмополости
мембранно-пневматические линзы классического типа
title Numerical study of the effect of individual racks in lenses on the operation of nonlinear lenticular membrane-pneumatic systems by the step method
title_full Numerical study of the effect of individual racks in lenses on the operation of nonlinear lenticular membrane-pneumatic systems by the step method
title_fullStr Numerical study of the effect of individual racks in lenses on the operation of nonlinear lenticular membrane-pneumatic systems by the step method
title_full_unstemmed Numerical study of the effect of individual racks in lenses on the operation of nonlinear lenticular membrane-pneumatic systems by the step method
title_short Numerical study of the effect of individual racks in lenses on the operation of nonlinear lenticular membrane-pneumatic systems by the step method
title_sort numerical study of the effect of individual racks in lenses on the operation of nonlinear lenticular membrane pneumatic systems by the step method
topic шагово - итерационный метод приращений параметров
усовершенствованной численной процедуры эйлера-коши
учетом геометрической и физической нелинейности упругой свойств воздуха в пневмополости
мембранно-пневматические линзы классического типа
url https://vestnik.dgtu.ru/jour/article/view/1046
work_keys_str_mv AT ayukim numericalstudyoftheeffectofindividualracksinlensesontheoperationofnonlinearlenticularmembranepneumaticsystemsbythestepmethod
AT mfamoyan numericalstudyoftheeffectofindividualracksinlensesontheoperationofnonlinearlenticularmembranepneumaticsystemsbythestepmethod
AT vekhapilin numericalstudyoftheeffectofindividualracksinlensesontheoperationofnonlinearlenticularmembranepneumaticsystemsbythestepmethod