Safety and feasibility of transcatheter renal sympathetic denervation using different types of catheter and various radiofrequency settings

Background: To evaluate in vivo the feasibility and safety of renal sympathetic denervation (RSD) with different catheters and various radiofrequency protocols. Methods and results: Twenty-two pigs were included. First 2 pigs were enrolled in a feasibility protocol using one catheter and power from...

Full description

Bibliographic Details
Main Authors: Bruno Rustum Andrea, Jacob Atié, Steffen Desh, Phillip Lurz, Gerhard Hindricks
Format: Article
Language:English
Published: Elsevier 2016-06-01
Series:International Journal of Cardiology: Heart & Vasculature
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2352906716300124
_version_ 1828330020263690240
author Bruno Rustum Andrea
Jacob Atié
Steffen Desh
Phillip Lurz
Gerhard Hindricks
author_facet Bruno Rustum Andrea
Jacob Atié
Steffen Desh
Phillip Lurz
Gerhard Hindricks
author_sort Bruno Rustum Andrea
collection DOAJ
description Background: To evaluate in vivo the feasibility and safety of renal sympathetic denervation (RSD) with different catheters and various radiofrequency protocols. Methods and results: Twenty-two pigs were included. First 2 pigs were enrolled in a feasibility protocol using one catheter and power from 5 W to 20 W. The next 10 pigs underwent RSD with three different catheters and four different RF-power settings of 5 W, 8 W, 10 W and 12 W in one minute per lesion (Protocol 1). The following 10 (Pigs 13 to 22) underwent RSD with five types of catheters (including the Symplicity® catheter), powers of 8 W and 10 W and two minutes RF-application (Protocol 2). Angiographic data were obtained at baseline, during and after RSD. At last, renal arteries were excised and analyzed macroscopically. The first pig developed severe renal stenoses with lesions of 15 to 20 W correlated with macroscopic alterations. The second feasibility pig did not develop renal stenosis with 5 and 8 W. In Protocol 1 from 60 RF-lesions, we observed 7 stenoses (≥30%). Three were severe (one of 80% with 10 W and two of 80% with 12 W). In Protocol 2 from 57 lesions we observed only 1 stenosis of 50% with 8 W with Symplicity® catheter. Severe stenosis was not observed. Conclusion: In this study, renal sympathetic denervation showed safety using five types of catheters when applying RF-energy less than 10 W, within main stems of arteries larger than 3.0 mm diameter and a distance between lesions of at least 1 time catheter tip length.
first_indexed 2024-04-13T20:34:42Z
format Article
id doaj.art-e1f1f0942477466f93a22b96cf376182
institution Directory Open Access Journal
issn 2352-9067
language English
last_indexed 2024-04-13T20:34:42Z
publishDate 2016-06-01
publisher Elsevier
record_format Article
series International Journal of Cardiology: Heart & Vasculature
spelling doaj.art-e1f1f0942477466f93a22b96cf3761822022-12-22T02:31:05ZengElsevierInternational Journal of Cardiology: Heart & Vasculature2352-90672016-06-0111C354210.1016/j.ijcha.2016.03.008Safety and feasibility of transcatheter renal sympathetic denervation using different types of catheter and various radiofrequency settingsBruno Rustum Andrea0Jacob Atié1Steffen Desh2Phillip Lurz3Gerhard Hindricks4Electrophysiology Department, Heart Center Leipzig, Leipzig, Sachsen, GermanyElectrophysiology Department, Clementino Fraga Filho University Hospital — UFRJ, Rio de Janeiro, RJ, BrazilCardiology Department, Heart Center Leipzig, Leipzig, Sachsen, GermanyCardiology Department, Heart Center Leipzig, Leipzig, Sachsen, GermanyElectrophysiology Department, Heart Center Leipzig, Leipzig, Sachsen, GermanyBackground: To evaluate in vivo the feasibility and safety of renal sympathetic denervation (RSD) with different catheters and various radiofrequency protocols. Methods and results: Twenty-two pigs were included. First 2 pigs were enrolled in a feasibility protocol using one catheter and power from 5 W to 20 W. The next 10 pigs underwent RSD with three different catheters and four different RF-power settings of 5 W, 8 W, 10 W and 12 W in one minute per lesion (Protocol 1). The following 10 (Pigs 13 to 22) underwent RSD with five types of catheters (including the Symplicity® catheter), powers of 8 W and 10 W and two minutes RF-application (Protocol 2). Angiographic data were obtained at baseline, during and after RSD. At last, renal arteries were excised and analyzed macroscopically. The first pig developed severe renal stenoses with lesions of 15 to 20 W correlated with macroscopic alterations. The second feasibility pig did not develop renal stenosis with 5 and 8 W. In Protocol 1 from 60 RF-lesions, we observed 7 stenoses (≥30%). Three were severe (one of 80% with 10 W and two of 80% with 12 W). In Protocol 2 from 57 lesions we observed only 1 stenosis of 50% with 8 W with Symplicity® catheter. Severe stenosis was not observed. Conclusion: In this study, renal sympathetic denervation showed safety using five types of catheters when applying RF-energy less than 10 W, within main stems of arteries larger than 3.0 mm diameter and a distance between lesions of at least 1 time catheter tip length.http://www.sciencedirect.com/science/article/pii/S2352906716300124Radiofrequency renal sympathetic denervationVarious ablation cathetersRadiofrequency protocolsSafety of renal denervation
spellingShingle Bruno Rustum Andrea
Jacob Atié
Steffen Desh
Phillip Lurz
Gerhard Hindricks
Safety and feasibility of transcatheter renal sympathetic denervation using different types of catheter and various radiofrequency settings
International Journal of Cardiology: Heart & Vasculature
Radiofrequency renal sympathetic denervation
Various ablation catheters
Radiofrequency protocols
Safety of renal denervation
title Safety and feasibility of transcatheter renal sympathetic denervation using different types of catheter and various radiofrequency settings
title_full Safety and feasibility of transcatheter renal sympathetic denervation using different types of catheter and various radiofrequency settings
title_fullStr Safety and feasibility of transcatheter renal sympathetic denervation using different types of catheter and various radiofrequency settings
title_full_unstemmed Safety and feasibility of transcatheter renal sympathetic denervation using different types of catheter and various radiofrequency settings
title_short Safety and feasibility of transcatheter renal sympathetic denervation using different types of catheter and various radiofrequency settings
title_sort safety and feasibility of transcatheter renal sympathetic denervation using different types of catheter and various radiofrequency settings
topic Radiofrequency renal sympathetic denervation
Various ablation catheters
Radiofrequency protocols
Safety of renal denervation
url http://www.sciencedirect.com/science/article/pii/S2352906716300124
work_keys_str_mv AT brunorustumandrea safetyandfeasibilityoftranscatheterrenalsympatheticdenervationusingdifferenttypesofcatheterandvariousradiofrequencysettings
AT jacobatie safetyandfeasibilityoftranscatheterrenalsympatheticdenervationusingdifferenttypesofcatheterandvariousradiofrequencysettings
AT steffendesh safetyandfeasibilityoftranscatheterrenalsympatheticdenervationusingdifferenttypesofcatheterandvariousradiofrequencysettings
AT philliplurz safetyandfeasibilityoftranscatheterrenalsympatheticdenervationusingdifferenttypesofcatheterandvariousradiofrequencysettings
AT gerhardhindricks safetyandfeasibilityoftranscatheterrenalsympatheticdenervationusingdifferenttypesofcatheterandvariousradiofrequencysettings