Analysis of the influence of electromagnetic interference of transmission lines on the data quality and positioning accuracy of Beidou deformation monitoring

In this paper, aiming at the application of geological disaster monitoring of transmission lines, by analyzing the data quality and positioning accuracy of Beidou original observation data, the influence of the electromagnetic environment of transmission lines on Beidou satellite monitoring data is...

Full description

Bibliographic Details
Main Authors: Xiaopo Mao, Zhiqiang Feng, Xiaoguo Deng, Zhijun Yu, Dongsheng He
Format: Article
Language:English
Published: AIP Publishing LLC 2022-09-01
Series:AIP Advances
Online Access:http://dx.doi.org/10.1063/5.0098038
_version_ 1811229571543990272
author Xiaopo Mao
Zhiqiang Feng
Xiaoguo Deng
Zhijun Yu
Dongsheng He
author_facet Xiaopo Mao
Zhiqiang Feng
Xiaoguo Deng
Zhijun Yu
Dongsheng He
author_sort Xiaopo Mao
collection DOAJ
description In this paper, aiming at the application of geological disaster monitoring of transmission lines, by analyzing the data quality and positioning accuracy of Beidou original observation data, the influence of the electromagnetic environment of transmission lines on Beidou satellite monitoring data is obtained. According to the Beidou monitoring data of 500 kV transmission line for 23 days, the analysis results show that: in the case of strong electromagnetic interference/no electromagnetic interference, the difference of data integrity is less than 1%, the difference of multipath effect is less than 0.1 m, the difference of signal-to-noise ratio is less than 0.3 dB Hz, and the difference of cycle hop ratio is less than 150. The relative difference in positioning accuracy is less than 5%. In general, the electromagnetic environment of transmission lines has no significant impact on the data quality and positioning accuracy of Beidou deformation monitoring.
first_indexed 2024-04-12T10:16:24Z
format Article
id doaj.art-e20a8bd2c5294aad9ca5e7df04055746
institution Directory Open Access Journal
issn 2158-3226
language English
last_indexed 2024-04-12T10:16:24Z
publishDate 2022-09-01
publisher AIP Publishing LLC
record_format Article
series AIP Advances
spelling doaj.art-e20a8bd2c5294aad9ca5e7df040557462022-12-22T03:37:11ZengAIP Publishing LLCAIP Advances2158-32262022-09-01129095325095325-910.1063/5.0098038Analysis of the influence of electromagnetic interference of transmission lines on the data quality and positioning accuracy of Beidou deformation monitoringXiaopo Mao0Zhiqiang Feng1Xiaoguo Deng2Zhijun Yu3Dongsheng He4State Grid Hubei Electric Power Co., Ltd., Electric Power Research Institute, Wuhan, Hubei 430077, ChinaState Grid Hubei Electric Power Co., Ltd., Electric Power Research Institute, Wuhan, Hubei 430077, ChinaState Grid Zhuzhou Power Supply Company, Zhuzhou, Hunan 412000, ChinaState Grid Enshi Electric Power Supply Company, Enshi, Hubei 445000, ChinaState Grid Zhuzhou Power Supply Company, Zhuzhou, Hunan 412000, ChinaIn this paper, aiming at the application of geological disaster monitoring of transmission lines, by analyzing the data quality and positioning accuracy of Beidou original observation data, the influence of the electromagnetic environment of transmission lines on Beidou satellite monitoring data is obtained. According to the Beidou monitoring data of 500 kV transmission line for 23 days, the analysis results show that: in the case of strong electromagnetic interference/no electromagnetic interference, the difference of data integrity is less than 1%, the difference of multipath effect is less than 0.1 m, the difference of signal-to-noise ratio is less than 0.3 dB Hz, and the difference of cycle hop ratio is less than 150. The relative difference in positioning accuracy is less than 5%. In general, the electromagnetic environment of transmission lines has no significant impact on the data quality and positioning accuracy of Beidou deformation monitoring.http://dx.doi.org/10.1063/5.0098038
spellingShingle Xiaopo Mao
Zhiqiang Feng
Xiaoguo Deng
Zhijun Yu
Dongsheng He
Analysis of the influence of electromagnetic interference of transmission lines on the data quality and positioning accuracy of Beidou deformation monitoring
AIP Advances
title Analysis of the influence of electromagnetic interference of transmission lines on the data quality and positioning accuracy of Beidou deformation monitoring
title_full Analysis of the influence of electromagnetic interference of transmission lines on the data quality and positioning accuracy of Beidou deformation monitoring
title_fullStr Analysis of the influence of electromagnetic interference of transmission lines on the data quality and positioning accuracy of Beidou deformation monitoring
title_full_unstemmed Analysis of the influence of electromagnetic interference of transmission lines on the data quality and positioning accuracy of Beidou deformation monitoring
title_short Analysis of the influence of electromagnetic interference of transmission lines on the data quality and positioning accuracy of Beidou deformation monitoring
title_sort analysis of the influence of electromagnetic interference of transmission lines on the data quality and positioning accuracy of beidou deformation monitoring
url http://dx.doi.org/10.1063/5.0098038
work_keys_str_mv AT xiaopomao analysisoftheinfluenceofelectromagneticinterferenceoftransmissionlinesonthedataqualityandpositioningaccuracyofbeidoudeformationmonitoring
AT zhiqiangfeng analysisoftheinfluenceofelectromagneticinterferenceoftransmissionlinesonthedataqualityandpositioningaccuracyofbeidoudeformationmonitoring
AT xiaoguodeng analysisoftheinfluenceofelectromagneticinterferenceoftransmissionlinesonthedataqualityandpositioningaccuracyofbeidoudeformationmonitoring
AT zhijunyu analysisoftheinfluenceofelectromagneticinterferenceoftransmissionlinesonthedataqualityandpositioningaccuracyofbeidoudeformationmonitoring
AT dongshenghe analysisoftheinfluenceofelectromagneticinterferenceoftransmissionlinesonthedataqualityandpositioningaccuracyofbeidoudeformationmonitoring