Ultracompact Multielectrode Array for Neurological Monitoring

Patients with paralysis, spinal cord injury, or amputated limbs could benefit from using brain−machine interface technology for communication and neurorehabilitation. In this study, a 32-channel three-dimensional (3D) multielectrode probe array was developed for the neural interface system...

Full description

Bibliographic Details
Main Authors: Ming-Yuan Cheng, Ramona B. Damalerio, Weiguo Chen, Ramamoorthy Rajkumar, Gavin S. Dawe
Format: Article
Language:English
Published: MDPI AG 2019-05-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/19/10/2286
_version_ 1798040365723287552
author Ming-Yuan Cheng
Ramona B. Damalerio
Weiguo Chen
Ramamoorthy Rajkumar
Gavin S. Dawe
author_facet Ming-Yuan Cheng
Ramona B. Damalerio
Weiguo Chen
Ramamoorthy Rajkumar
Gavin S. Dawe
author_sort Ming-Yuan Cheng
collection DOAJ
description Patients with paralysis, spinal cord injury, or amputated limbs could benefit from using brain−machine interface technology for communication and neurorehabilitation. In this study, a 32-channel three-dimensional (3D) multielectrode probe array was developed for the neural interface system of a brain−machine interface to monitor neural activity. A novel microassembly technique involving lead transfer was used to prevent misalignment in the bonding plane during the orthogonal assembly of the 3D multielectrode probe array. Standard microassembly and biopackaging processes were utilized to implement the proposed lead transfer technique. The maximum profile of the integrated 3D neural device was set to 0.50 mm above the pia mater to reduce trauma to brain cells. Benchtop tests characterized the electrical impedance of the neural device. A characterization test revealed that the impedance of the 3D multielectrode probe array was on average approximately 0.55 MΩ at a frequency of 1 KHz. Moreover, in vitro cytotoxicity tests verified the biocompatibility of the device. Subsequently, 3D multielectrode probe arrays were implanted in rats and exhibited the capability to record local field potentials and spike signals.
first_indexed 2024-04-11T22:06:37Z
format Article
id doaj.art-e25bf26486184c308e7c954e5eea5618
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-04-11T22:06:37Z
publishDate 2019-05-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-e25bf26486184c308e7c954e5eea56182022-12-22T04:00:42ZengMDPI AGSensors1424-82202019-05-011910228610.3390/s19102286s19102286Ultracompact Multielectrode Array for Neurological MonitoringMing-Yuan Cheng0Ramona B. Damalerio1Weiguo Chen2Ramamoorthy Rajkumar3Gavin S. Dawe4Institute of Microelectronics, Agency for Science, Technology and Research, Singapore 138634, SingaporeInstitute of Microelectronics, Agency for Science, Technology and Research, Singapore 138634, SingaporeInstitute of Microelectronics, Agency for Science, Technology and Research, Singapore 138634, SingaporeDepartment of Pharmacology, Yong Loo Lin School of Medicine, National University Health System, National University of Singapore, Singapore 117600, SingaporeDepartment of Pharmacology, Yong Loo Lin School of Medicine, National University Health System, National University of Singapore, Singapore 117600, SingaporePatients with paralysis, spinal cord injury, or amputated limbs could benefit from using brain−machine interface technology for communication and neurorehabilitation. In this study, a 32-channel three-dimensional (3D) multielectrode probe array was developed for the neural interface system of a brain−machine interface to monitor neural activity. A novel microassembly technique involving lead transfer was used to prevent misalignment in the bonding plane during the orthogonal assembly of the 3D multielectrode probe array. Standard microassembly and biopackaging processes were utilized to implement the proposed lead transfer technique. The maximum profile of the integrated 3D neural device was set to 0.50 mm above the pia mater to reduce trauma to brain cells. Benchtop tests characterized the electrical impedance of the neural device. A characterization test revealed that the impedance of the 3D multielectrode probe array was on average approximately 0.55 MΩ at a frequency of 1 KHz. Moreover, in vitro cytotoxicity tests verified the biocompatibility of the device. Subsequently, 3D multielectrode probe arrays were implanted in rats and exhibited the capability to record local field potentials and spike signals.https://www.mdpi.com/1424-8220/19/10/2286biopackaginglead transferneural probe array microassemblymicroelectromechanical systems
spellingShingle Ming-Yuan Cheng
Ramona B. Damalerio
Weiguo Chen
Ramamoorthy Rajkumar
Gavin S. Dawe
Ultracompact Multielectrode Array for Neurological Monitoring
Sensors
biopackaging
lead transfer
neural probe array microassembly
microelectromechanical systems
title Ultracompact Multielectrode Array for Neurological Monitoring
title_full Ultracompact Multielectrode Array for Neurological Monitoring
title_fullStr Ultracompact Multielectrode Array for Neurological Monitoring
title_full_unstemmed Ultracompact Multielectrode Array for Neurological Monitoring
title_short Ultracompact Multielectrode Array for Neurological Monitoring
title_sort ultracompact multielectrode array for neurological monitoring
topic biopackaging
lead transfer
neural probe array microassembly
microelectromechanical systems
url https://www.mdpi.com/1424-8220/19/10/2286
work_keys_str_mv AT mingyuancheng ultracompactmultielectrodearrayforneurologicalmonitoring
AT ramonabdamalerio ultracompactmultielectrodearrayforneurologicalmonitoring
AT weiguochen ultracompactmultielectrodearrayforneurologicalmonitoring
AT ramamoorthyrajkumar ultracompactmultielectrodearrayforneurologicalmonitoring
AT gavinsdawe ultracompactmultielectrodearrayforneurologicalmonitoring