Develop a Sensor System to Calculate the Mutual Pressure Between the Socket and Limb in Amputation above the Knee

This research aims to develop a system of thin slice sensors that rely on the principle of variable electrical resistors and invested in the calculation of the mutual pressure between the socket and limb prosthesis from above the knee because this pressure is important in determining the efficiency...

Full description

Bibliographic Details
Main Authors: Raed Najjar, Yara Mohammad, Ghader Ali
Format: Article
Language:Arabic
Published: Tishreen University 2019-12-01
Series:مجلة جامعة تشرين للبحوث والدراسات العلمية- سلسلة العلوم الهندسية
Online Access:https://journal.tishreen.edu.sy/index.php/engscnc/article/view/9324
_version_ 1797676042299637760
author Raed Najjar
Yara Mohammad
Ghader Ali
author_facet Raed Najjar
Yara Mohammad
Ghader Ali
author_sort Raed Najjar
collection DOAJ
description This research aims to develop a system of thin slice sensors that rely on the principle of variable electrical resistors and invested in the calculation of the mutual pressure between the socket and limb prosthesis from above the knee because this pressure is important in determining the efficiency of the prosthesis as the quality of the prosthesis depends on The quality of the socket and the quality of the socket in turn are linked to the optimal distribution of pressure on loadable and non-loadable areas. In five cases of prosthesis alignment through the angle between the knee axis and the socket axis, pressure was calculated for an amputee above the knee at the age of 35 years. The patient was satisfied and it was found that the most suitable angle or the studied condition ranged between 14 - 16 degrees in the front direction corresponding to the direction of normal walking يهدف هذا البحث إلى تطوير نظام من الحساسات الشرائحية الرقيقة التي تعتمد على مبدأ المقاومات الكهربائية المتغيرة و استثمارها في حساب الضغط المتبادل بين الجذمور و قميص طرف صناعي من ما فوق الركبة لما لهذا الضغط من أهمية في تحديد كفاءة الطرف الصناعي حيث أن جودة الطرف الصناعي تتوقف على جودة القميص و جودة القميص بدورها ترتبط بالتوزع الأمثل للضغط على المناطق القابلة للتحميل و المناطق غير القابلة للتحميل .تم حساب الضغط لمصاب بالبتر من ما فوق الركبة يبلغ من العمر 35 عاماً و ذلك في خمس حالات لتسامت الطرف الصناعي من خلال الزاوية بين محور الركبة الصناعية و محور القميص, تم وضع معايير لتقيم كفاءة القميص و زوايا التسامت المثالية بالاعتماد على نظام الحساسات و التجربة و رضى المصاب و تبين أن زاواية التسامت المثالية للحالة المدروسة تراوحت بين 14 – 16 درجة في الاتجاه الأمامي الموافق لاتجاه المشي الطبيعي .
first_indexed 2024-03-11T22:22:26Z
format Article
id doaj.art-e27f7ae0d9a04bbba91d4f458f88202f
institution Directory Open Access Journal
issn 2079-3081
2663-4279
language Arabic
last_indexed 2024-03-11T22:22:26Z
publishDate 2019-12-01
publisher Tishreen University
record_format Article
series مجلة جامعة تشرين للبحوث والدراسات العلمية- سلسلة العلوم الهندسية
spelling doaj.art-e27f7ae0d9a04bbba91d4f458f88202f2023-09-24T11:03:09ZaraTishreen Universityمجلة جامعة تشرين للبحوث والدراسات العلمية- سلسلة العلوم الهندسية2079-30812663-42792019-12-01416Develop a Sensor System to Calculate the Mutual Pressure Between the Socket and Limb in Amputation above the KneeRaed NajjarYara MohammadGhader Ali This research aims to develop a system of thin slice sensors that rely on the principle of variable electrical resistors and invested in the calculation of the mutual pressure between the socket and limb prosthesis from above the knee because this pressure is important in determining the efficiency of the prosthesis as the quality of the prosthesis depends on The quality of the socket and the quality of the socket in turn are linked to the optimal distribution of pressure on loadable and non-loadable areas. In five cases of prosthesis alignment through the angle between the knee axis and the socket axis, pressure was calculated for an amputee above the knee at the age of 35 years. The patient was satisfied and it was found that the most suitable angle or the studied condition ranged between 14 - 16 degrees in the front direction corresponding to the direction of normal walking يهدف هذا البحث إلى تطوير نظام من الحساسات الشرائحية الرقيقة التي تعتمد على مبدأ المقاومات الكهربائية المتغيرة و استثمارها في حساب الضغط المتبادل بين الجذمور و قميص طرف صناعي من ما فوق الركبة لما لهذا الضغط من أهمية في تحديد كفاءة الطرف الصناعي حيث أن جودة الطرف الصناعي تتوقف على جودة القميص و جودة القميص بدورها ترتبط بالتوزع الأمثل للضغط على المناطق القابلة للتحميل و المناطق غير القابلة للتحميل .تم حساب الضغط لمصاب بالبتر من ما فوق الركبة يبلغ من العمر 35 عاماً و ذلك في خمس حالات لتسامت الطرف الصناعي من خلال الزاوية بين محور الركبة الصناعية و محور القميص, تم وضع معايير لتقيم كفاءة القميص و زوايا التسامت المثالية بالاعتماد على نظام الحساسات و التجربة و رضى المصاب و تبين أن زاواية التسامت المثالية للحالة المدروسة تراوحت بين 14 – 16 درجة في الاتجاه الأمامي الموافق لاتجاه المشي الطبيعي . https://journal.tishreen.edu.sy/index.php/engscnc/article/view/9324
spellingShingle Raed Najjar
Yara Mohammad
Ghader Ali
Develop a Sensor System to Calculate the Mutual Pressure Between the Socket and Limb in Amputation above the Knee
مجلة جامعة تشرين للبحوث والدراسات العلمية- سلسلة العلوم الهندسية
title Develop a Sensor System to Calculate the Mutual Pressure Between the Socket and Limb in Amputation above the Knee
title_full Develop a Sensor System to Calculate the Mutual Pressure Between the Socket and Limb in Amputation above the Knee
title_fullStr Develop a Sensor System to Calculate the Mutual Pressure Between the Socket and Limb in Amputation above the Knee
title_full_unstemmed Develop a Sensor System to Calculate the Mutual Pressure Between the Socket and Limb in Amputation above the Knee
title_short Develop a Sensor System to Calculate the Mutual Pressure Between the Socket and Limb in Amputation above the Knee
title_sort develop a sensor system to calculate the mutual pressure between the socket and limb in amputation above the knee
url https://journal.tishreen.edu.sy/index.php/engscnc/article/view/9324
work_keys_str_mv AT raednajjar developasensorsystemtocalculatethemutualpressurebetweenthesocketandlimbinamputationabovetheknee
AT yaramohammad developasensorsystemtocalculatethemutualpressurebetweenthesocketandlimbinamputationabovetheknee
AT ghaderali developasensorsystemtocalculatethemutualpressurebetweenthesocketandlimbinamputationabovetheknee