Cationic Lignin Polymers as Flocculant for Municipal Wastewater

The radical polymerization of acid-washed and unwashed softwood kraft lignin with [2-(methacryloyloxy) ethyl] trimethylammonium chloride (METAC) was attempted to investigate the production of lignin-based flocculants for simulated wastewater. The incorporation of METAC onto lignin resulted in a cati...

Full description

Bibliographic Details
Main Authors: Courtney Moore, Weijue Gao, Pedram Fatehi
Format: Article
Language:English
Published: MDPI AG 2021-11-01
Series:Polymers
Subjects:
Online Access:https://www.mdpi.com/2073-4360/13/22/3871
_version_ 1797508691930382336
author Courtney Moore
Weijue Gao
Pedram Fatehi
author_facet Courtney Moore
Weijue Gao
Pedram Fatehi
author_sort Courtney Moore
collection DOAJ
description The radical polymerization of acid-washed and unwashed softwood kraft lignin with [2-(methacryloyloxy) ethyl] trimethylammonium chloride (METAC) was attempted to investigate the production of lignin-based flocculants for simulated wastewater. The incorporation of METAC onto lignin resulted in a cationic charge density (2.3–3.3 meq/g), increased water solubility (89–96% in neutral pH), and increased molecular weight (70,000–210,000 g/mol) of lignin. The lignin–METAC polymers generated from acid-washed lignin had higher molecular weights than those generated from unwashed lignin. The lignin–METAC polymers showed lower resistance to thermal decomposition than unmodified lignin due to the inclusion of PolyMETAC. The unmodified acid-washed lignin samples did not significantly affect the COD of the wastewater, while the unmodified unwashed lignin samples contributed to the COD, implying that unmodified lignin was not suitable for wastewater treatment. The flocculation of wastewater with lignin–METAC led to the chemical oxygen demand (COD) reduction of 17–23% and total organic carbon (TOC) drop of 51–60%. The lignin–METAC polymer with the highest molecular weight (produced from acid-washed lignin) reached the highest COD removal, while lignin–METAC polymer with the highest charge density (produced from unwashed lignin) reached the highest TOC removal. Focused beam reflectance measurement (FBRM) studies revealed that the lignin–METAC polymer produced from acid-washed lignin with a high molecular weight generated larger and more flocs in wastewater than the lignin–METAC polymer produced from unwashed lignin. The comparison of theoretical and experimental dosages required for neutralizing the charges of wastewater demonstrated that charge neutralization was the main flocculation mechanism, although a bridging mechanism was also involved for component removals from wastewater. The use of 1 mg/L of alum along with 65 mg/L lignin–METAC in a dual coagulation–flocculation system led to higher average phosphorous (42%) and COD (44%) removals than the singular flocculation system only using 65 mg/L of lignin–METAC (with phosphorous removals of 3.4% and COD removals of 18.7%). However, lignin–METAC flocculant slightly increased the ammonia–nitrogen content in both singular flocculation and dual coagulation–flocculation systems due to the residual ammonia content of lignin–METAC. The coagulation–flocculation system determined that the use of lignin–METAC (65 mg/L) could reduce the alum dosage significantly while maintaining a similar organic content reduction of 44% for wastewater.
first_indexed 2024-03-10T05:07:30Z
format Article
id doaj.art-e3342caafd354f8d886e7aeafb4cfcab
institution Directory Open Access Journal
issn 2073-4360
language English
last_indexed 2024-03-10T05:07:30Z
publishDate 2021-11-01
publisher MDPI AG
record_format Article
series Polymers
spelling doaj.art-e3342caafd354f8d886e7aeafb4cfcab2023-11-23T01:07:53ZengMDPI AGPolymers2073-43602021-11-011322387110.3390/polym13223871Cationic Lignin Polymers as Flocculant for Municipal WastewaterCourtney Moore0Weijue Gao1Pedram Fatehi2Green Processes Research Centre and Biorefining Research Institute, Lakehead University, Thunder Bay, ON P7B5E1, CanadaGreen Processes Research Centre and Biorefining Research Institute, Lakehead University, Thunder Bay, ON P7B5E1, CanadaGreen Processes Research Centre and Biorefining Research Institute, Lakehead University, Thunder Bay, ON P7B5E1, CanadaThe radical polymerization of acid-washed and unwashed softwood kraft lignin with [2-(methacryloyloxy) ethyl] trimethylammonium chloride (METAC) was attempted to investigate the production of lignin-based flocculants for simulated wastewater. The incorporation of METAC onto lignin resulted in a cationic charge density (2.3–3.3 meq/g), increased water solubility (89–96% in neutral pH), and increased molecular weight (70,000–210,000 g/mol) of lignin. The lignin–METAC polymers generated from acid-washed lignin had higher molecular weights than those generated from unwashed lignin. The lignin–METAC polymers showed lower resistance to thermal decomposition than unmodified lignin due to the inclusion of PolyMETAC. The unmodified acid-washed lignin samples did not significantly affect the COD of the wastewater, while the unmodified unwashed lignin samples contributed to the COD, implying that unmodified lignin was not suitable for wastewater treatment. The flocculation of wastewater with lignin–METAC led to the chemical oxygen demand (COD) reduction of 17–23% and total organic carbon (TOC) drop of 51–60%. The lignin–METAC polymer with the highest molecular weight (produced from acid-washed lignin) reached the highest COD removal, while lignin–METAC polymer with the highest charge density (produced from unwashed lignin) reached the highest TOC removal. Focused beam reflectance measurement (FBRM) studies revealed that the lignin–METAC polymer produced from acid-washed lignin with a high molecular weight generated larger and more flocs in wastewater than the lignin–METAC polymer produced from unwashed lignin. The comparison of theoretical and experimental dosages required for neutralizing the charges of wastewater demonstrated that charge neutralization was the main flocculation mechanism, although a bridging mechanism was also involved for component removals from wastewater. The use of 1 mg/L of alum along with 65 mg/L lignin–METAC in a dual coagulation–flocculation system led to higher average phosphorous (42%) and COD (44%) removals than the singular flocculation system only using 65 mg/L of lignin–METAC (with phosphorous removals of 3.4% and COD removals of 18.7%). However, lignin–METAC flocculant slightly increased the ammonia–nitrogen content in both singular flocculation and dual coagulation–flocculation systems due to the residual ammonia content of lignin–METAC. The coagulation–flocculation system determined that the use of lignin–METAC (65 mg/L) could reduce the alum dosage significantly while maintaining a similar organic content reduction of 44% for wastewater.https://www.mdpi.com/2073-4360/13/22/3871lignin polymerizationflocculationcoagulationmunicipal wastewater
spellingShingle Courtney Moore
Weijue Gao
Pedram Fatehi
Cationic Lignin Polymers as Flocculant for Municipal Wastewater
Polymers
lignin polymerization
flocculation
coagulation
municipal wastewater
title Cationic Lignin Polymers as Flocculant for Municipal Wastewater
title_full Cationic Lignin Polymers as Flocculant for Municipal Wastewater
title_fullStr Cationic Lignin Polymers as Flocculant for Municipal Wastewater
title_full_unstemmed Cationic Lignin Polymers as Flocculant for Municipal Wastewater
title_short Cationic Lignin Polymers as Flocculant for Municipal Wastewater
title_sort cationic lignin polymers as flocculant for municipal wastewater
topic lignin polymerization
flocculation
coagulation
municipal wastewater
url https://www.mdpi.com/2073-4360/13/22/3871
work_keys_str_mv AT courtneymoore cationicligninpolymersasflocculantformunicipalwastewater
AT weijuegao cationicligninpolymersasflocculantformunicipalwastewater
AT pedramfatehi cationicligninpolymersasflocculantformunicipalwastewater