Experimental Study on Seismic Performance of Prefabricated Monolithic Concrete–Polystyrene Panel Composite Wall Panels

A normal composite wall panel is a structural component composed of polystyrene insulation boards and concrete surface layers reinforced with steel wire mesh. It can be entirely prefabricated in a factory or constructed with the concrete surface layers cast on-site. A novel prefabricated monolithic...

Full description

Bibliographic Details
Main Authors: Kaozhong Zhao, Zijia Fan, Yuming Zhang, Yufeng Xu, Sihong Liu
Format: Article
Language:English
Published: MDPI AG 2024-02-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/14/2/442
_version_ 1797298724177707008
author Kaozhong Zhao
Zijia Fan
Yuming Zhang
Yufeng Xu
Sihong Liu
author_facet Kaozhong Zhao
Zijia Fan
Yuming Zhang
Yufeng Xu
Sihong Liu
author_sort Kaozhong Zhao
collection DOAJ
description A normal composite wall panel is a structural component composed of polystyrene insulation boards and concrete surface layers reinforced with steel wire mesh. It can be entirely prefabricated in a factory or constructed with the concrete surface layers cast on-site. A novel prefabricated monolithic concrete–polystyrene panel composite wall panel (CPC wall panel) is proposed in this study. The CPC panel features a middle part that is prefabricated in the factory while the reinforced concrete regions at its two side ends are cast on-site. To evaluate the seismic performance of the wall panel, 18 CPC specimens were designed, manufactured, and quasi-statically tested, through which the structural behaviors, failure mode, and load-bearing capacity were studied. In addition, the influences of the height-to-width ratio and the vertical compressive stress level on the seismic performance of the CPC panels were also investigated. The test results showed that the connectors spaced at 400 mm × 500 mm could ensure the concrete layers on both sides of the polystyrene board worked collectively under seismic conditions. When subjected to lateral loads, the interface between the newly poured concrete and the existing concrete exhibited good bonding. Moreover, the failure mode of the CPC wall panel was largely correlated to the height-to-width ratio that, for specimens having four steel bars of 12 mm diameter and a height-to-width ratio greater than 1, the flexural failure was initially developed, followed by diagonal shear failure. In specimens with a height-to-width ratio of 1, flexural and diagonal shear failures occurred almost simultaneously. For specimens with a height-to-width ratio of less than 1, the final diagonal shear failure was predominant. The longitudinal reinforcing bars at the two ends of the CPC panels could effectively improve their lateral load-bearing capacity, with the enhancement influenced by the height-to-width ratio, the vertical load applied to the wall panel, and the cross-sectional area of the steel bars. In practice, the lateral load-bearing capacity of the CPC panel can be conservatively evaluated using the calculation method of the reinforced concrete shear walls. Finally, the ductility of the CPC specimens was affected by the height-to-width ratio and the axial compressive stress level, such that the specimens with a larger height-to-width ratio and lower axial compressive stress exhibited better ductility.
first_indexed 2024-03-07T22:40:08Z
format Article
id doaj.art-e3707d753ea54e09b334c2078f873c93
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-07T22:40:08Z
publishDate 2024-02-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-e3707d753ea54e09b334c2078f873c932024-02-23T15:10:15ZengMDPI AGBuildings2075-53092024-02-0114244210.3390/buildings14020442Experimental Study on Seismic Performance of Prefabricated Monolithic Concrete–Polystyrene Panel Composite Wall PanelsKaozhong Zhao0Zijia Fan1Yuming Zhang2Yufeng Xu3Sihong Liu4School of Civil Engineering, Shandong Jianzhu University, Jinan 250101, ChinaSchool of Civil Engineering, Shandong Jianzhu University, Jinan 250101, ChinaSchool of Civil Engineering, Shandong Jianzhu University, Jinan 250101, ChinaSchool of Civil Engineering, Shandong Jianzhu University, Jinan 250101, ChinaSchool of Civil Engineering, Shandong Jianzhu University, Jinan 250101, ChinaA normal composite wall panel is a structural component composed of polystyrene insulation boards and concrete surface layers reinforced with steel wire mesh. It can be entirely prefabricated in a factory or constructed with the concrete surface layers cast on-site. A novel prefabricated monolithic concrete–polystyrene panel composite wall panel (CPC wall panel) is proposed in this study. The CPC panel features a middle part that is prefabricated in the factory while the reinforced concrete regions at its two side ends are cast on-site. To evaluate the seismic performance of the wall panel, 18 CPC specimens were designed, manufactured, and quasi-statically tested, through which the structural behaviors, failure mode, and load-bearing capacity were studied. In addition, the influences of the height-to-width ratio and the vertical compressive stress level on the seismic performance of the CPC panels were also investigated. The test results showed that the connectors spaced at 400 mm × 500 mm could ensure the concrete layers on both sides of the polystyrene board worked collectively under seismic conditions. When subjected to lateral loads, the interface between the newly poured concrete and the existing concrete exhibited good bonding. Moreover, the failure mode of the CPC wall panel was largely correlated to the height-to-width ratio that, for specimens having four steel bars of 12 mm diameter and a height-to-width ratio greater than 1, the flexural failure was initially developed, followed by diagonal shear failure. In specimens with a height-to-width ratio of 1, flexural and diagonal shear failures occurred almost simultaneously. For specimens with a height-to-width ratio of less than 1, the final diagonal shear failure was predominant. The longitudinal reinforcing bars at the two ends of the CPC panels could effectively improve their lateral load-bearing capacity, with the enhancement influenced by the height-to-width ratio, the vertical load applied to the wall panel, and the cross-sectional area of the steel bars. In practice, the lateral load-bearing capacity of the CPC panel can be conservatively evaluated using the calculation method of the reinforced concrete shear walls. Finally, the ductility of the CPC specimens was affected by the height-to-width ratio and the axial compressive stress level, such that the specimens with a larger height-to-width ratio and lower axial compressive stress exhibited better ductility.https://www.mdpi.com/2075-5309/14/2/442prefabricated monolithicreinforced concretecomposite wall panelsseismic performancequasi-static test
spellingShingle Kaozhong Zhao
Zijia Fan
Yuming Zhang
Yufeng Xu
Sihong Liu
Experimental Study on Seismic Performance of Prefabricated Monolithic Concrete–Polystyrene Panel Composite Wall Panels
Buildings
prefabricated monolithic
reinforced concrete
composite wall panels
seismic performance
quasi-static test
title Experimental Study on Seismic Performance of Prefabricated Monolithic Concrete–Polystyrene Panel Composite Wall Panels
title_full Experimental Study on Seismic Performance of Prefabricated Monolithic Concrete–Polystyrene Panel Composite Wall Panels
title_fullStr Experimental Study on Seismic Performance of Prefabricated Monolithic Concrete–Polystyrene Panel Composite Wall Panels
title_full_unstemmed Experimental Study on Seismic Performance of Prefabricated Monolithic Concrete–Polystyrene Panel Composite Wall Panels
title_short Experimental Study on Seismic Performance of Prefabricated Monolithic Concrete–Polystyrene Panel Composite Wall Panels
title_sort experimental study on seismic performance of prefabricated monolithic concrete polystyrene panel composite wall panels
topic prefabricated monolithic
reinforced concrete
composite wall panels
seismic performance
quasi-static test
url https://www.mdpi.com/2075-5309/14/2/442
work_keys_str_mv AT kaozhongzhao experimentalstudyonseismicperformanceofprefabricatedmonolithicconcretepolystyrenepanelcompositewallpanels
AT zijiafan experimentalstudyonseismicperformanceofprefabricatedmonolithicconcretepolystyrenepanelcompositewallpanels
AT yumingzhang experimentalstudyonseismicperformanceofprefabricatedmonolithicconcretepolystyrenepanelcompositewallpanels
AT yufengxu experimentalstudyonseismicperformanceofprefabricatedmonolithicconcretepolystyrenepanelcompositewallpanels
AT sihongliu experimentalstudyonseismicperformanceofprefabricatedmonolithicconcretepolystyrenepanelcompositewallpanels