Design of reduced size long counter with flat response function from few keV to 20 MeV
In this study, a reduced size neutron long counter with improved response function was designed using SuperMC simulation code. The main parts of the reduced size long counter are 3He proportional counter, cylindrical moderators made of polyethylene, chromium metal converter, neutron absorbe...
Main Authors: | Mazunga Mohamed, JI Xiang, Li Taosheng, Li Yanan |
---|---|
Format: | Article |
Language: | English |
Published: |
VINCA Institute of Nuclear Sciences
2016-01-01
|
Series: | Nuclear Technology and Radiation Protection |
Subjects: | |
Online Access: | http://www.doiserbia.nb.rs/img/doi/1451-3994/2016/1451-39941604361M.pdf |
Similar Items
-
Simulation and experimental characterization of an energy-extended neutron long counter
by: LI Yanan, et al.
Published: (2022-06-01) -
Characterization of the collimated output fluence , in a thermal neutron field, in terms of ambient equivalent dose H*(10,0)
by: Larissa Paizante Santos da Silva, et al.
Published: (2022-12-01) -
New experiment for measuring the delayed neutron yields of 238U fission in the range 1 MeV to 19 MeV
by: Belverge D., et al.
Published: (2023-01-01) -
APPLICATION OF SUPERMC3.2 TO PRELIMINARY NEUTRONICS ANALYSIS FOR EUROPEAN HCPB DEMO
by: Li Bin, et al.
Published: (2021-01-01) -
Validation of Shielding Analysis Capability of SuperMC with SINBAD
by: Chen Chaobin, et al.
Published: (2017-01-01)