Assessment of Thermal Comfort in Rooms Equipped with a Decentralised Façade Ventilation Unit

Thermal comfort affects not only the well-being of the occupants of a building but also the effectiveness of their learning and work efficiency. It can be disturbed if the ventilation airflow is increased when improving indoor air quality. When natural ventilation is used in the fall and winter peri...

Full description

Bibliographic Details
Main Authors: Ewa Zender-Świercz, Marek Telejko, Beata Galiszewska, Mariola Starzomska
Format: Article
Language:English
Published: MDPI AG 2022-09-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/15/19/7032
_version_ 1797479622764396544
author Ewa Zender-Świercz
Marek Telejko
Beata Galiszewska
Mariola Starzomska
author_facet Ewa Zender-Świercz
Marek Telejko
Beata Galiszewska
Mariola Starzomska
author_sort Ewa Zender-Świercz
collection DOAJ
description Thermal comfort affects not only the well-being of the occupants of a building but also the effectiveness of their learning and work efficiency. It can be disturbed if the ventilation airflow is increased when improving indoor air quality. When natural ventilation is used in the fall and winter period, the supply air temperature is low, resulting in a lack of thermal comfort. In existing buildings, there is often no place for mechanical ventilation; hence, decentralised façade ventilation units are increasingly used. The article presents an analysis of thermal comfort in rooms with this type of unit equipped with heat recovery exchangers of different efficiencies. Studies have shown that the alternating supply/exhaust airflow and the related unevenness of air streams flowing through the heat accumulator cause an inflow of low-temperature air, resulting in thermal discomfort. The highest value of the PMV index was −1.6, and the lowest was −4.1, which means that 54.8 to 100% of the occupants are dissatisfied with their thermal comfort. This means there is a need to change the construction of inlet/exhaust vents so that the stream of supply air is not directly parallel to the floor. In addition, the use of an air heater should be considered.
first_indexed 2024-03-09T21:48:27Z
format Article
id doaj.art-e4133a499a544ac09a6a84124586106b
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-09T21:48:27Z
publishDate 2022-09-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-e4133a499a544ac09a6a84124586106b2023-11-23T20:12:00ZengMDPI AGEnergies1996-10732022-09-011519703210.3390/en15197032Assessment of Thermal Comfort in Rooms Equipped with a Decentralised Façade Ventilation UnitEwa Zender-Świercz0Marek Telejko1Beata Galiszewska2Mariola Starzomska3Department of Building Physics and Renewable Energy, Faculty of Environmental, Geomatic and Energy Engineering, Kielce University of Technology, 25-314 Kielce, PolandDepartment of Building Organization and Building Materials, Faculty of Civil Engineering and Architecture, Kielce University of Technology, 25-314 Kielce, PolandDepartment of Building Physics and Renewable Energy, Faculty of Environmental, Geomatic and Energy Engineering, Kielce University of Technology, 25-314 Kielce, PolandDepartment of Building Physics and Renewable Energy, Faculty of Environmental, Geomatic and Energy Engineering, Kielce University of Technology, 25-314 Kielce, PolandThermal comfort affects not only the well-being of the occupants of a building but also the effectiveness of their learning and work efficiency. It can be disturbed if the ventilation airflow is increased when improving indoor air quality. When natural ventilation is used in the fall and winter period, the supply air temperature is low, resulting in a lack of thermal comfort. In existing buildings, there is often no place for mechanical ventilation; hence, decentralised façade ventilation units are increasingly used. The article presents an analysis of thermal comfort in rooms with this type of unit equipped with heat recovery exchangers of different efficiencies. Studies have shown that the alternating supply/exhaust airflow and the related unevenness of air streams flowing through the heat accumulator cause an inflow of low-temperature air, resulting in thermal discomfort. The highest value of the PMV index was −1.6, and the lowest was −4.1, which means that 54.8 to 100% of the occupants are dissatisfied with their thermal comfort. This means there is a need to change the construction of inlet/exhaust vents so that the stream of supply air is not directly parallel to the floor. In addition, the use of an air heater should be considered.https://www.mdpi.com/1996-1073/15/19/7032thermal comfortdecentralised façade ventilation unitsstorage heat exchangers for heat recovery
spellingShingle Ewa Zender-Świercz
Marek Telejko
Beata Galiszewska
Mariola Starzomska
Assessment of Thermal Comfort in Rooms Equipped with a Decentralised Façade Ventilation Unit
Energies
thermal comfort
decentralised façade ventilation units
storage heat exchangers for heat recovery
title Assessment of Thermal Comfort in Rooms Equipped with a Decentralised Façade Ventilation Unit
title_full Assessment of Thermal Comfort in Rooms Equipped with a Decentralised Façade Ventilation Unit
title_fullStr Assessment of Thermal Comfort in Rooms Equipped with a Decentralised Façade Ventilation Unit
title_full_unstemmed Assessment of Thermal Comfort in Rooms Equipped with a Decentralised Façade Ventilation Unit
title_short Assessment of Thermal Comfort in Rooms Equipped with a Decentralised Façade Ventilation Unit
title_sort assessment of thermal comfort in rooms equipped with a decentralised facade ventilation unit
topic thermal comfort
decentralised façade ventilation units
storage heat exchangers for heat recovery
url https://www.mdpi.com/1996-1073/15/19/7032
work_keys_str_mv AT ewazenderswiercz assessmentofthermalcomfortinroomsequippedwithadecentralisedfacadeventilationunit
AT marektelejko assessmentofthermalcomfortinroomsequippedwithadecentralisedfacadeventilationunit
AT beatagaliszewska assessmentofthermalcomfortinroomsequippedwithadecentralisedfacadeventilationunit
AT mariolastarzomska assessmentofthermalcomfortinroomsequippedwithadecentralisedfacadeventilationunit