Study of the effectiveness of water mist curtain in blocking fire-induced smoke in tunnel by means of CFD simulations

Tunnel fire smoke control is an important issue in the area of tunnel fire safety. Inspired by fire compartmentation in buildings, it is worth investigating whether a tunnel can be partitioned by a water mist system into a fire zone and safety zones. If so, people can move from the fire zone into a...

Full description

Bibliographic Details
Main Authors: Sun Jiayun, Xu Hang, Shi Dunke, Zheng Fang, Zhao Fuyun
Format: Article
Language:English
Published: EDP Sciences 2022-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2022/23/e3sconf_roomvent2022_02015.pdf