The Experimental Evaluation of Energy Efficiency and Carbonic Emission Rates for All Stable Loads of Larger-Scale (+600 MW) Coal-Fired Power Generation Units in Vietnam
Performance guarantees and tests of thermal power plants are usually carried out at 100% rate output capacity. However, fossil-fired power plants have decreased full load hours, affecting energy efficiency, and are subjected to frequent load changes caused by variable renewable electricity and poten...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-03-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/15/6/2185 |
_version_ | 1797446725190811648 |
---|---|
author | Anh T. Hoang Tuyen V. Nguyen Bao T. Nguyen |
author_facet | Anh T. Hoang Tuyen V. Nguyen Bao T. Nguyen |
author_sort | Anh T. Hoang |
collection | DOAJ |
description | Performance guarantees and tests of thermal power plants are usually carried out at 100% rate output capacity. However, fossil-fired power plants have decreased full load hours, affecting energy efficiency, and are subjected to frequent load changes caused by variable renewable electricity and potential grid stability. Therefore, this study is conducted to calculate and draw the characteristic curves for all stable loads of coal-fired power units including the 60%, 75%, and 100% rate output. The study focuses on the corrected plant net heat rates—gross unit outputs, net standard coal consumption rates—throttle steam pressures, and corrected plant net efficiencies—carbonic emission rates. In addition, the experimental investigation for energy efficiency and carbonic emission of the latest larger-scale (+600 MW) coal-fired power generation units in Vietnam are also implemented using a performance guarantee calculation software called “PG_Cal” version 0.0, which is based on a mass and energy balance method by MATLAB programing language. From the results of this study, it is suggested that the performance guarantees and tests of new coal-fired units should be carried out at different stable loads, including minimum load. Vietnam should apply the ultra-supercritical technology for new units in order to increase their efficiency and decrease carbon dioxide emissions. |
first_indexed | 2024-03-09T13:44:43Z |
format | Article |
id | doaj.art-e4ffb3acb2734329840fba5b0ac98872 |
institution | Directory Open Access Journal |
issn | 1996-1073 |
language | English |
last_indexed | 2024-03-09T13:44:43Z |
publishDate | 2022-03-01 |
publisher | MDPI AG |
record_format | Article |
series | Energies |
spelling | doaj.art-e4ffb3acb2734329840fba5b0ac988722023-11-30T21:02:10ZengMDPI AGEnergies1996-10732022-03-01156218510.3390/en15062185The Experimental Evaluation of Energy Efficiency and Carbonic Emission Rates for All Stable Loads of Larger-Scale (+600 MW) Coal-Fired Power Generation Units in VietnamAnh T. Hoang0Tuyen V. Nguyen1Bao T. Nguyen2Division of Heat & Refrigeration Engineering, Faculty of Mechanical Engineering, Ho Chi Minh City University of Technology (HCMUT), Ho Chi Minh City 740500, VietnamDivision of Heat & Refrigeration Engineering, Faculty of Mechanical Engineering, Ho Chi Minh City University of Technology (HCMUT), Ho Chi Minh City 740500, VietnamDivision of Heat & Refrigeration Engineering, Faculty of Mechanical Engineering, Ho Chi Minh City University of Technology (HCMUT), Ho Chi Minh City 740500, VietnamPerformance guarantees and tests of thermal power plants are usually carried out at 100% rate output capacity. However, fossil-fired power plants have decreased full load hours, affecting energy efficiency, and are subjected to frequent load changes caused by variable renewable electricity and potential grid stability. Therefore, this study is conducted to calculate and draw the characteristic curves for all stable loads of coal-fired power units including the 60%, 75%, and 100% rate output. The study focuses on the corrected plant net heat rates—gross unit outputs, net standard coal consumption rates—throttle steam pressures, and corrected plant net efficiencies—carbonic emission rates. In addition, the experimental investigation for energy efficiency and carbonic emission of the latest larger-scale (+600 MW) coal-fired power generation units in Vietnam are also implemented using a performance guarantee calculation software called “PG_Cal” version 0.0, which is based on a mass and energy balance method by MATLAB programing language. From the results of this study, it is suggested that the performance guarantees and tests of new coal-fired units should be carried out at different stable loads, including minimum load. Vietnam should apply the ultra-supercritical technology for new units in order to increase their efficiency and decrease carbon dioxide emissions.https://www.mdpi.com/1996-1073/15/6/2185coal-fired power plantenergy efficiencycoal consumptionperformance guaranteescarbonic emission |
spellingShingle | Anh T. Hoang Tuyen V. Nguyen Bao T. Nguyen The Experimental Evaluation of Energy Efficiency and Carbonic Emission Rates for All Stable Loads of Larger-Scale (+600 MW) Coal-Fired Power Generation Units in Vietnam Energies coal-fired power plant energy efficiency coal consumption performance guarantees carbonic emission |
title | The Experimental Evaluation of Energy Efficiency and Carbonic Emission Rates for All Stable Loads of Larger-Scale (+600 MW) Coal-Fired Power Generation Units in Vietnam |
title_full | The Experimental Evaluation of Energy Efficiency and Carbonic Emission Rates for All Stable Loads of Larger-Scale (+600 MW) Coal-Fired Power Generation Units in Vietnam |
title_fullStr | The Experimental Evaluation of Energy Efficiency and Carbonic Emission Rates for All Stable Loads of Larger-Scale (+600 MW) Coal-Fired Power Generation Units in Vietnam |
title_full_unstemmed | The Experimental Evaluation of Energy Efficiency and Carbonic Emission Rates for All Stable Loads of Larger-Scale (+600 MW) Coal-Fired Power Generation Units in Vietnam |
title_short | The Experimental Evaluation of Energy Efficiency and Carbonic Emission Rates for All Stable Loads of Larger-Scale (+600 MW) Coal-Fired Power Generation Units in Vietnam |
title_sort | experimental evaluation of energy efficiency and carbonic emission rates for all stable loads of larger scale 600 mw coal fired power generation units in vietnam |
topic | coal-fired power plant energy efficiency coal consumption performance guarantees carbonic emission |
url | https://www.mdpi.com/1996-1073/15/6/2185 |
work_keys_str_mv | AT anhthoang theexperimentalevaluationofenergyefficiencyandcarbonicemissionratesforallstableloadsoflargerscale600mwcoalfiredpowergenerationunitsinvietnam AT tuyenvnguyen theexperimentalevaluationofenergyefficiencyandcarbonicemissionratesforallstableloadsoflargerscale600mwcoalfiredpowergenerationunitsinvietnam AT baotnguyen theexperimentalevaluationofenergyefficiencyandcarbonicemissionratesforallstableloadsoflargerscale600mwcoalfiredpowergenerationunitsinvietnam AT anhthoang experimentalevaluationofenergyefficiencyandcarbonicemissionratesforallstableloadsoflargerscale600mwcoalfiredpowergenerationunitsinvietnam AT tuyenvnguyen experimentalevaluationofenergyefficiencyandcarbonicemissionratesforallstableloadsoflargerscale600mwcoalfiredpowergenerationunitsinvietnam AT baotnguyen experimentalevaluationofenergyefficiencyandcarbonicemissionratesforallstableloadsoflargerscale600mwcoalfiredpowergenerationunitsinvietnam |