Analysis of the accuracy of 14C in gaseous effluent of nuclear power plant by direct measurement method

BackgroundThere is no national standard specifically for the analysis of gaseous effluents 14C from nuclear power plants in China, only one group standard available for reference. The group standard is technical specification for 14C analysis of gaseous effluents for nuclear power plants (TBSRS 005―...

Full description

Bibliographic Details
Main Authors: ZHEN Liying, ZHANG Jiajun, LIN Yinghui, CHEN Rirong, WANG Zuohe
Format: Article
Language:zho
Published: Science Press 2022-09-01
Series:He jishu
Subjects:
Online Access:http://www.hjs.sinap.ac.cn/thesisDetails#10.11889/j.0253-3219.2022.hjs.45.090301&lang=zh
_version_ 1811169665436614656
author ZHEN Liying
ZHANG Jiajun
LIN Yinghui
CHEN Rirong
WANG Zuohe
author_facet ZHEN Liying
ZHANG Jiajun
LIN Yinghui
CHEN Rirong
WANG Zuohe
author_sort ZHEN Liying
collection DOAJ
description BackgroundThere is no national standard specifically for the analysis of gaseous effluents 14C from nuclear power plants in China, only one group standard available for reference. The group standard is technical specification for 14C analysis of gaseous effluents for nuclear power plants (TBSRS 005―2019). Most nuclear power plants in China refer to this group standard and use direct measurement method to analyze 14C in gaseous effluent.PurposeThis study aims to investigate the accuracy of 14C in gaseous effluent of nuclear power plant by the direct measurement method.MethodsA series of experiments were carried out, including optimal ratio of sample and scintillation cocktail, quenching effect, entrainment of tritium and influent factors of tritium on the analysis of 14C. The optimal ratio of sample and scintillation cocktail was selected after measuring different volume ratios of sample and scintillation liquid. The experiment of quenching effect was to measure the samples with different quenching degrees and to observe the influence of different quenching degrees on the measurement efficiency. Entrainment of tritium and the influence level experiment of tritium was to determine the existence of entrainment of tritium through the comparison of samples spectrogram, and to determine the influence level of tritium on the counting of 14C by added different proportions of tritium to 14C sample. Finally, direct measurement results of sixty-seven 14C samples of gaseous effluent from a nuclear power plant were statistically analyzed.ResultsThe experimental results show that tritium is entrained in the gaseous effluent 14C sample when the HAGUE 7000 14C sampler is used, and 1%~2% of the entrainment of tritium is contributed to the count of 14C. The optimal ratio of sample and scintillation cocktail is 6 mL vs. 14 mL. The difference of sample quenching causes the deviation of detection efficiency. The direct measurement results of sixty-seven 14C samples show that the maximum efficiency difference of 4.6% is introduced for different quenching degrees of samples.ConclusionThe main factors affecting the accuracy of the direct measurement method are the ratio of sample and scintillation cocktail, entrainment of tritium and accuracy of detection efficiency. The influence of entrainment of tritium can be reduced by resolving spectral channel, using suspension analysis method or changing sampling method.
first_indexed 2024-04-10T16:46:00Z
format Article
id doaj.art-e51092ebb45c4f7f9d2eb5cc4caa3940
institution Directory Open Access Journal
issn 0253-3219
language zho
last_indexed 2024-04-10T16:46:00Z
publishDate 2022-09-01
publisher Science Press
record_format Article
series He jishu
spelling doaj.art-e51092ebb45c4f7f9d2eb5cc4caa39402023-02-08T01:03:28ZzhoScience PressHe jishu0253-32192022-09-0145909030109030110.11889/j.0253-3219.2022.hjs.45.0903010253-3219(2022)09-0033-08Analysis of the accuracy of 14C in gaseous effluent of nuclear power plant by direct measurement methodZHEN LiyingZHANG JiajunLIN YinghuiCHEN RirongWANG ZuoheBackgroundThere is no national standard specifically for the analysis of gaseous effluents 14C from nuclear power plants in China, only one group standard available for reference. The group standard is technical specification for 14C analysis of gaseous effluents for nuclear power plants (TBSRS 005―2019). Most nuclear power plants in China refer to this group standard and use direct measurement method to analyze 14C in gaseous effluent.PurposeThis study aims to investigate the accuracy of 14C in gaseous effluent of nuclear power plant by the direct measurement method.MethodsA series of experiments were carried out, including optimal ratio of sample and scintillation cocktail, quenching effect, entrainment of tritium and influent factors of tritium on the analysis of 14C. The optimal ratio of sample and scintillation cocktail was selected after measuring different volume ratios of sample and scintillation liquid. The experiment of quenching effect was to measure the samples with different quenching degrees and to observe the influence of different quenching degrees on the measurement efficiency. Entrainment of tritium and the influence level experiment of tritium was to determine the existence of entrainment of tritium through the comparison of samples spectrogram, and to determine the influence level of tritium on the counting of 14C by added different proportions of tritium to 14C sample. Finally, direct measurement results of sixty-seven 14C samples of gaseous effluent from a nuclear power plant were statistically analyzed.ResultsThe experimental results show that tritium is entrained in the gaseous effluent 14C sample when the HAGUE 7000 14C sampler is used, and 1%~2% of the entrainment of tritium is contributed to the count of 14C. The optimal ratio of sample and scintillation cocktail is 6 mL vs. 14 mL. The difference of sample quenching causes the deviation of detection efficiency. The direct measurement results of sixty-seven 14C samples show that the maximum efficiency difference of 4.6% is introduced for different quenching degrees of samples.ConclusionThe main factors affecting the accuracy of the direct measurement method are the ratio of sample and scintillation cocktail, entrainment of tritium and accuracy of detection efficiency. The influence of entrainment of tritium can be reduced by resolving spectral channel, using suspension analysis method or changing sampling method.http://www.hjs.sinap.ac.cn/thesisDetails#10.11889/j.0253-3219.2022.hjs.45.090301&lang=zhnuclear power plant14c in gaseous effluententrainment of tritiumdirect measurement method
spellingShingle ZHEN Liying
ZHANG Jiajun
LIN Yinghui
CHEN Rirong
WANG Zuohe
Analysis of the accuracy of 14C in gaseous effluent of nuclear power plant by direct measurement method
He jishu
nuclear power plant
14c in gaseous effluent
entrainment of tritium
direct measurement method
title Analysis of the accuracy of 14C in gaseous effluent of nuclear power plant by direct measurement method
title_full Analysis of the accuracy of 14C in gaseous effluent of nuclear power plant by direct measurement method
title_fullStr Analysis of the accuracy of 14C in gaseous effluent of nuclear power plant by direct measurement method
title_full_unstemmed Analysis of the accuracy of 14C in gaseous effluent of nuclear power plant by direct measurement method
title_short Analysis of the accuracy of 14C in gaseous effluent of nuclear power plant by direct measurement method
title_sort analysis of the accuracy of 14c in gaseous effluent of nuclear power plant by direct measurement method
topic nuclear power plant
14c in gaseous effluent
entrainment of tritium
direct measurement method
url http://www.hjs.sinap.ac.cn/thesisDetails#10.11889/j.0253-3219.2022.hjs.45.090301&lang=zh
work_keys_str_mv AT zhenliying analysisoftheaccuracyof14cingaseouseffluentofnuclearpowerplantbydirectmeasurementmethod
AT zhangjiajun analysisoftheaccuracyof14cingaseouseffluentofnuclearpowerplantbydirectmeasurementmethod
AT linyinghui analysisoftheaccuracyof14cingaseouseffluentofnuclearpowerplantbydirectmeasurementmethod
AT chenrirong analysisoftheaccuracyof14cingaseouseffluentofnuclearpowerplantbydirectmeasurementmethod
AT wangzuohe analysisoftheaccuracyof14cingaseouseffluentofnuclearpowerplantbydirectmeasurementmethod