Estimating the Product of the X-ray Spectrum and Quantum Detection Efficiency of a CT System and Its Application to Beam Hardening Correction

Lab-based X-ray computed tomography (XCT) systems use X-ray sources that emit a polychromatic X-ray spectrum and detectors that do not detect all X-ray photons with the same efficiency. A consequence of using a polychromatic X-ray source is that beam hardening artefacts may be present in the reconst...

Full description

Bibliographic Details
Main Authors: Joseph J. Lifton, Andrew A. Malcolm
Format: Article
Language:English
Published: MDPI AG 2021-05-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/21/9/3284
_version_ 1827693025258635264
author Joseph J. Lifton
Andrew A. Malcolm
author_facet Joseph J. Lifton
Andrew A. Malcolm
author_sort Joseph J. Lifton
collection DOAJ
description Lab-based X-ray computed tomography (XCT) systems use X-ray sources that emit a polychromatic X-ray spectrum and detectors that do not detect all X-ray photons with the same efficiency. A consequence of using a polychromatic X-ray source is that beam hardening artefacts may be present in the reconstructed data, and the presence of such artefacts can degrade XCT image quality and affect quantitative analysis. If the product of the X-ray spectrum and the quantum detection efficiency (QDE) of the detector are known, alongside the material of the scanned object, then beam hardening artefacts can be corrected algorithmically. In this work, a method for estimating the product of the X-ray spectrum and the detector’s QDE is offered. The method approximates the product of the X-ray spectrum and the QDE as a Bézier curve, which requires only eight fitting parameters to be estimated. It is shown experimentally and through simulation that Bézier curves can be used to accurately simulate polychromatic attenuation and hence be used to correct beam hardening artefacts. The proposed method is tested using measured attenuation data and then used to calculate a beam hardening correction for an aluminium workpiece; the beam hardening correction leads to an increase in the contrast-to-noise ratio of the XCT data by 41% and the removal of cupping artefacts. Deriving beam hardening corrections in this manner is more versatile than using conventional material-specific step wedges.
first_indexed 2024-03-10T11:35:04Z
format Article
id doaj.art-e603d74f982442ae8aa08dbeac581791
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-10T11:35:04Z
publishDate 2021-05-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-e603d74f982442ae8aa08dbeac5817912023-11-21T18:58:00ZengMDPI AGSensors1424-82202021-05-01219328410.3390/s21093284Estimating the Product of the X-ray Spectrum and Quantum Detection Efficiency of a CT System and Its Application to Beam Hardening CorrectionJoseph J. Lifton0Andrew A. Malcolm1Advanced Remanufacturing and Technology Centre, 3 Cleantech Loop, CleanTech Two, Singapore 637143, SingaporeAdvanced Remanufacturing and Technology Centre, 3 Cleantech Loop, CleanTech Two, Singapore 637143, SingaporeLab-based X-ray computed tomography (XCT) systems use X-ray sources that emit a polychromatic X-ray spectrum and detectors that do not detect all X-ray photons with the same efficiency. A consequence of using a polychromatic X-ray source is that beam hardening artefacts may be present in the reconstructed data, and the presence of such artefacts can degrade XCT image quality and affect quantitative analysis. If the product of the X-ray spectrum and the quantum detection efficiency (QDE) of the detector are known, alongside the material of the scanned object, then beam hardening artefacts can be corrected algorithmically. In this work, a method for estimating the product of the X-ray spectrum and the detector’s QDE is offered. The method approximates the product of the X-ray spectrum and the QDE as a Bézier curve, which requires only eight fitting parameters to be estimated. It is shown experimentally and through simulation that Bézier curves can be used to accurately simulate polychromatic attenuation and hence be used to correct beam hardening artefacts. The proposed method is tested using measured attenuation data and then used to calculate a beam hardening correction for an aluminium workpiece; the beam hardening correction leads to an increase in the contrast-to-noise ratio of the XCT data by 41% and the removal of cupping artefacts. Deriving beam hardening corrections in this manner is more versatile than using conventional material-specific step wedges.https://www.mdpi.com/1424-8220/21/9/3284X-ray spectrumquantum detection efficiencybeam hardeningBézier curvelinearisation
spellingShingle Joseph J. Lifton
Andrew A. Malcolm
Estimating the Product of the X-ray Spectrum and Quantum Detection Efficiency of a CT System and Its Application to Beam Hardening Correction
Sensors
X-ray spectrum
quantum detection efficiency
beam hardening
Bézier curve
linearisation
title Estimating the Product of the X-ray Spectrum and Quantum Detection Efficiency of a CT System and Its Application to Beam Hardening Correction
title_full Estimating the Product of the X-ray Spectrum and Quantum Detection Efficiency of a CT System and Its Application to Beam Hardening Correction
title_fullStr Estimating the Product of the X-ray Spectrum and Quantum Detection Efficiency of a CT System and Its Application to Beam Hardening Correction
title_full_unstemmed Estimating the Product of the X-ray Spectrum and Quantum Detection Efficiency of a CT System and Its Application to Beam Hardening Correction
title_short Estimating the Product of the X-ray Spectrum and Quantum Detection Efficiency of a CT System and Its Application to Beam Hardening Correction
title_sort estimating the product of the x ray spectrum and quantum detection efficiency of a ct system and its application to beam hardening correction
topic X-ray spectrum
quantum detection efficiency
beam hardening
Bézier curve
linearisation
url https://www.mdpi.com/1424-8220/21/9/3284
work_keys_str_mv AT josephjlifton estimatingtheproductofthexrayspectrumandquantumdetectionefficiencyofactsystemanditsapplicationtobeamhardeningcorrection
AT andrewamalcolm estimatingtheproductofthexrayspectrumandquantumdetectionefficiencyofactsystemanditsapplicationtobeamhardeningcorrection