Parameters of a cascade two-stage air-to-water heat pump at low ambient temperature

The results of the numerical calculation of the thermodynamic parameters of a cascade (two-stage) air-to-water heat pump at low atmospheric air temperatures are presented. A Freon R407c is used in the first circuit and a R152a is used in the second circuit. Calculations are made for ambient temperat...

Full description

Bibliographic Details
Main Authors: Аndriy Redko, Adam Ujma, Serhii Pavlovskyi, Ihor Redko, Oleksandr Gvozdetskii, Yurii Chaika, Dmytro Borodai
Format: Article
Language:English
Published: The Publishing Office of Czestochowa University of Technology 2023-10-01
Series:Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Subjects:
Online Access:https://bozpe.pcz.pl/archives/2023/bozpe-2023-15
_version_ 1797383292868100096
author Аndriy Redko
Adam Ujma
Serhii Pavlovskyi
Ihor Redko
Oleksandr Gvozdetskii
Yurii Chaika
Dmytro Borodai
author_facet Аndriy Redko
Adam Ujma
Serhii Pavlovskyi
Ihor Redko
Oleksandr Gvozdetskii
Yurii Chaika
Dmytro Borodai
author_sort Аndriy Redko
collection DOAJ
description The results of the numerical calculation of the thermodynamic parameters of a cascade (two-stage) air-to-water heat pump at low atmospheric air temperatures are presented. A Freon R407c is used in the first circuit and a R152a is used in the second circuit. Calculations are made for ambient temperatures from 7°С to –25°С. The effect of underrecovery temperatures in heat exchange equipment is shown. Cycles with R245fa, R142b, R114, R123, R290, R236fa, R600a refrigerants, a mixture of isobutane and isopentane have been investigated. The effect of the complexity of a two-stage scheme on the efficiency of the cycle has been evaluated. The use of more complex schemes (for example, with liquid injection) does not affect the thermodynamic perfection of the heat pump and may be appropriate only to ensure operational reliability. Reducing the underrecovery temperature to 1 K is shown to increase the thermodynamic efficiency of the installation.
first_indexed 2024-03-08T21:18:51Z
format Article
id doaj.art-e60d1c7584104c3c82798dd3ba2e4a73
institution Directory Open Access Journal
issn 2299-8535
2544-963X
language English
last_indexed 2024-03-08T21:18:51Z
publishDate 2023-10-01
publisher The Publishing Office of Czestochowa University of Technology
record_format Article
series Budownictwo o Zoptymalizowanym Potencjale Energetycznym
spelling doaj.art-e60d1c7584104c3c82798dd3ba2e4a732023-12-21T13:18:21ZengThe Publishing Office of Czestochowa University of TechnologyBudownictwo o Zoptymalizowanym Potencjale Energetycznym2299-85352544-963X2023-10-0112132142doi.org/10.17512/bozpe.2023.12.15Parameters of a cascade two-stage air-to-water heat pump at low ambient temperatureАndriy Redko0https://orcid.org/0000-0003-2331-7273Adam Ujma1https://orcid.org/0000-0001-5331-6808Serhii Pavlovskyi2https://orcid.org/0000-0002-9891-2133Ihor Redko3https://orcid.org/0000-0002-9863-4487Oleksandr Gvozdetskii4https://orcid.org/0000-0001-5590-4689Yurii Chaika5https://orcid.org/0000-0003-1021-4662Dmytro Borodai6https://orcid.org/0000-0002-0771-9769O.M. Beketov National University of Urban Economy in Kharkiv, Ukraine Czestochowa University of Technology, Poland O.M. Beketov National University of Urban Economy in Kharkiv, Ukraine Ukrainian State University of Railway Transport, Ukraine O.M. Beketov National University of Urban Economy in Kharkiv, Ukraine O.M. Beketov National University of Urban Economy in Kharkiv, Ukraine Sumy National Agrarian University, Ukraine The results of the numerical calculation of the thermodynamic parameters of a cascade (two-stage) air-to-water heat pump at low atmospheric air temperatures are presented. A Freon R407c is used in the first circuit and a R152a is used in the second circuit. Calculations are made for ambient temperatures from 7°С to –25°С. The effect of underrecovery temperatures in heat exchange equipment is shown. Cycles with R245fa, R142b, R114, R123, R290, R236fa, R600a refrigerants, a mixture of isobutane and isopentane have been investigated. The effect of the complexity of a two-stage scheme on the efficiency of the cycle has been evaluated. The use of more complex schemes (for example, with liquid injection) does not affect the thermodynamic perfection of the heat pump and may be appropriate only to ensure operational reliability. Reducing the underrecovery temperature to 1 K is shown to increase the thermodynamic efficiency of the installation.https://bozpe.pcz.pl/archives/2023/bozpe-2023-15heat pumplow air temperaturerefrigerantthermodynamic parameters
spellingShingle Аndriy Redko
Adam Ujma
Serhii Pavlovskyi
Ihor Redko
Oleksandr Gvozdetskii
Yurii Chaika
Dmytro Borodai
Parameters of a cascade two-stage air-to-water heat pump at low ambient temperature
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
heat pump
low air temperature
refrigerant
thermodynamic parameters
title Parameters of a cascade two-stage air-to-water heat pump at low ambient temperature
title_full Parameters of a cascade two-stage air-to-water heat pump at low ambient temperature
title_fullStr Parameters of a cascade two-stage air-to-water heat pump at low ambient temperature
title_full_unstemmed Parameters of a cascade two-stage air-to-water heat pump at low ambient temperature
title_short Parameters of a cascade two-stage air-to-water heat pump at low ambient temperature
title_sort parameters of a cascade two stage air to water heat pump at low ambient temperature
topic heat pump
low air temperature
refrigerant
thermodynamic parameters
url https://bozpe.pcz.pl/archives/2023/bozpe-2023-15
work_keys_str_mv AT andriyredko parametersofacascadetwostageairtowaterheatpumpatlowambienttemperature
AT adamujma parametersofacascadetwostageairtowaterheatpumpatlowambienttemperature
AT serhiipavlovskyi parametersofacascadetwostageairtowaterheatpumpatlowambienttemperature
AT ihorredko parametersofacascadetwostageairtowaterheatpumpatlowambienttemperature
AT oleksandrgvozdetskii parametersofacascadetwostageairtowaterheatpumpatlowambienttemperature
AT yuriichaika parametersofacascadetwostageairtowaterheatpumpatlowambienttemperature
AT dmytroborodai parametersofacascadetwostageairtowaterheatpumpatlowambienttemperature