A sensorless efficiency test system for a high-speed permanent magnet synchronous motor

Abstract We present a sensorless efficiency test system with energy recovery for a high-speed permanent magnet synchronous motor (PMSM). In the system, two identical high-speed PMSMs are used as the motor under test (MUT) and the load machine (LM), respectively. A new sensorless vector control (VC)...

Full description

Bibliographic Details
Main Authors: Li JI, Yixiang SHAO, Sujie GAO
Format: Article
Language:English
Published: IEEE 2018-12-01
Series:Journal of Modern Power Systems and Clean Energy
Subjects:
Online Access:http://link.springer.com/article/10.1007/s40565-018-0482-5
Description
Summary:Abstract We present a sensorless efficiency test system with energy recovery for a high-speed permanent magnet synchronous motor (PMSM). In the system, two identical high-speed PMSMs are used as the motor under test (MUT) and the load machine (LM), respectively. A new sensorless vector control (VC) method based on a hypothetical reference frame is presented to control both the MUT and the LM. Also, a regenerating unit is used to implement energy circulation to save energy. Experiments were carried out on a prototype, with a digital controller based on the TMS320F28335, to verify the adequacy of the sensorless VC method. As a result, the efficiency test system achieves the load test at the speed of 21000 r/min without any reduction equipment. During the test, the energy regenerated by the LM could be fed back to the MUT by the regenerating unit, and 81.31% electrical power was saved. In addition, with the proposed sensorless VC method, both the MUT and the LM can work at i d   = 0 without a position sensor.
ISSN:2196-5625
2196-5420