Valuation of the Reliability of the Formulas of the Yo-Yo Intermittent Recovery Test (Level 1) and 30-15 IFT, which are Intermittent Endurance Tests Used to Determine Maximum Oxygen Capacity

For athletes to perform high-intensity movements with high quality, anaerobic endurance must be developed in order to repeat these movements one after the other with the same quality and without fatigue. Aerobic and anaerobic endurance characteristics should be followed by using tests suitable for t...

Full description

Bibliographic Details
Main Authors: Nurettin Ersin Uzun, Tuba Kızılet Bozdoğan, Ali Kızılet
Format: Article
Language:English
Published: ümit doğan üstün 2021-08-01
Series:Sportif Bakış Spor ve Eğitim Bilimleri Dergisi
Subjects:
_version_ 1828019071223857152
author Nurettin Ersin Uzun
Tuba Kızılet Bozdoğan
Ali Kızılet
author_facet Nurettin Ersin Uzun
Tuba Kızılet Bozdoğan
Ali Kızılet
author_sort Nurettin Ersin Uzun
collection DOAJ
description For athletes to perform high-intensity movements with high quality, anaerobic endurance must be developed in order to repeat these movements one after the other with the same quality and without fatigue. Aerobic and anaerobic endurance characteristics should be followed by using tests suitable for the requirements and structure of the sports branch before and during the season. The aim of this study is to determine the maximal oxygen consumption (MaxVo2) with indirect MaxVo2 values ​​obtained with the help of formulas from "Yo-yo Intermittent Recovery Test (level 1) (YATT1)" and "30-15 Intermittent Endurance Test (30-15 IFT)". The purpose of this study is to compare the direct MaxVo2 value determined by using an oxygen analyzer in these tests and to examine the reliability of the formulas. The sample group of the study consists of 12 male athletes with an average age of 21.7 ± 1.2 who play futsal and badminton licensed in Marmara University Faculty of Sports Sciences. MaxVo2 values ​​of the athletes were determined indirectly by putting the test result into the test formula, and directly by the oxygen analyzer on the athletes during the test. According to the results of the study, a correlation was determined between direct and indirect measurement methods according to the results of the correlation test of the data obtained from YATT1 and 30-15 IFT (respectively; 828**, p=0.001 and 816** p=0.001). According to the results of the co-sample t-test performed for the measurement methods themselves, a statistically significant difference was found between the two measurement methods (p= 0.002 and p=0.019, respectively). Finally, while there was no statistically significant difference between direct measurements of YATT1 and 30-15 IFT (p=.454), a statistically significant difference was found between indirect measurements (p=0.002). According to the results of the study, it is appropriate to use both direct and indirect measurement methods of YATT1 or 30-15 IFT tests, considering the sport-specific features, in determining MaxVo2.
first_indexed 2024-04-10T11:12:55Z
format Article
id doaj.art-e620262fd8ae4e7ea02349df01f1a3d5
institution Directory Open Access Journal
issn 2148-905X
language English
last_indexed 2024-04-10T11:12:55Z
publishDate 2021-08-01
publisher ümit doğan üstün
record_format Article
series Sportif Bakış Spor ve Eğitim Bilimleri Dergisi
spelling doaj.art-e620262fd8ae4e7ea02349df01f1a3d52023-02-15T16:19:00Zengümit doğan üstünSportif Bakış Spor ve Eğitim Bilimleri Dergisi2148-905X2021-08-018226828010.33468/sbsebd.221Valuation of the Reliability of the Formulas of the Yo-Yo Intermittent Recovery Test (Level 1) and 30-15 IFT, which are Intermittent Endurance Tests Used to Determine Maximum Oxygen CapacityNurettin Ersin Uzun0Tuba Kızılet Bozdoğan1Ali Kızılet2Marmara UniversityMarmara UniversityMarmara UniversityFor athletes to perform high-intensity movements with high quality, anaerobic endurance must be developed in order to repeat these movements one after the other with the same quality and without fatigue. Aerobic and anaerobic endurance characteristics should be followed by using tests suitable for the requirements and structure of the sports branch before and during the season. The aim of this study is to determine the maximal oxygen consumption (MaxVo2) with indirect MaxVo2 values ​​obtained with the help of formulas from "Yo-yo Intermittent Recovery Test (level 1) (YATT1)" and "30-15 Intermittent Endurance Test (30-15 IFT)". The purpose of this study is to compare the direct MaxVo2 value determined by using an oxygen analyzer in these tests and to examine the reliability of the formulas. The sample group of the study consists of 12 male athletes with an average age of 21.7 ± 1.2 who play futsal and badminton licensed in Marmara University Faculty of Sports Sciences. MaxVo2 values ​​of the athletes were determined indirectly by putting the test result into the test formula, and directly by the oxygen analyzer on the athletes during the test. According to the results of the study, a correlation was determined between direct and indirect measurement methods according to the results of the correlation test of the data obtained from YATT1 and 30-15 IFT (respectively; 828**, p=0.001 and 816** p=0.001). According to the results of the co-sample t-test performed for the measurement methods themselves, a statistically significant difference was found between the two measurement methods (p= 0.002 and p=0.019, respectively). Finally, while there was no statistically significant difference between direct measurements of YATT1 and 30-15 IFT (p=.454), a statistically significant difference was found between indirect measurements (p=0.002). According to the results of the study, it is appropriate to use both direct and indirect measurement methods of YATT1 or 30-15 IFT tests, considering the sport-specific features, in determining MaxVo2.endurance testsmaximum aerobic capacityyo-yo test30-15 ift
spellingShingle Nurettin Ersin Uzun
Tuba Kızılet Bozdoğan
Ali Kızılet
Valuation of the Reliability of the Formulas of the Yo-Yo Intermittent Recovery Test (Level 1) and 30-15 IFT, which are Intermittent Endurance Tests Used to Determine Maximum Oxygen Capacity
Sportif Bakış Spor ve Eğitim Bilimleri Dergisi
endurance tests
maximum aerobic capacity
yo-yo test
30-15 ift
title Valuation of the Reliability of the Formulas of the Yo-Yo Intermittent Recovery Test (Level 1) and 30-15 IFT, which are Intermittent Endurance Tests Used to Determine Maximum Oxygen Capacity
title_full Valuation of the Reliability of the Formulas of the Yo-Yo Intermittent Recovery Test (Level 1) and 30-15 IFT, which are Intermittent Endurance Tests Used to Determine Maximum Oxygen Capacity
title_fullStr Valuation of the Reliability of the Formulas of the Yo-Yo Intermittent Recovery Test (Level 1) and 30-15 IFT, which are Intermittent Endurance Tests Used to Determine Maximum Oxygen Capacity
title_full_unstemmed Valuation of the Reliability of the Formulas of the Yo-Yo Intermittent Recovery Test (Level 1) and 30-15 IFT, which are Intermittent Endurance Tests Used to Determine Maximum Oxygen Capacity
title_short Valuation of the Reliability of the Formulas of the Yo-Yo Intermittent Recovery Test (Level 1) and 30-15 IFT, which are Intermittent Endurance Tests Used to Determine Maximum Oxygen Capacity
title_sort valuation of the reliability of the formulas of the yo yo intermittent recovery test level 1 and 30 15 ift which are intermittent endurance tests used to determine maximum oxygen capacity
topic endurance tests
maximum aerobic capacity
yo-yo test
30-15 ift
work_keys_str_mv AT nurettinersinuzun valuationofthereliabilityoftheformulasoftheyoyointermittentrecoverytestlevel1and3015iftwhichareintermittentendurancetestsusedtodeterminemaximumoxygencapacity
AT tubakızıletbozdogan valuationofthereliabilityoftheformulasoftheyoyointermittentrecoverytestlevel1and3015iftwhichareintermittentendurancetestsusedtodeterminemaximumoxygencapacity
AT alikızılet valuationofthereliabilityoftheformulasoftheyoyointermittentrecoverytestlevel1and3015iftwhichareintermittentendurancetestsusedtodeterminemaximumoxygencapacity