Implementation of the energy management standard NC 50001 (up to energetic-planning phase) in a telecommunication company
This paper presents the results of energetic planning phase of the management standard NC ISO 50001 implemented in a telecommunications company. It was made taking into account the requirements set by existing regulations and key issues were determined such as the institution’s policy regarding ener...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidad Tecnológica de La Habana, José Antonio Echeverría
2020-09-01
|
Series: | Revista Científica de Ingeniería Energética |
Subjects: | |
Online Access: | https://rie.cujae.edu.cu/index.php/RIE/article/view/603/pdf |
_version_ | 1811338109742219264 |
---|---|
author | Yamile Díaz Torres Mario A. Alvares Guerra Plasencia Alejandro Valdés López Lester Pimentel Cabrera Onelio Castillo Barrios Dries Haeseldonck |
author_facet | Yamile Díaz Torres Mario A. Alvares Guerra Plasencia Alejandro Valdés López Lester Pimentel Cabrera Onelio Castillo Barrios Dries Haeseldonck |
author_sort | Yamile Díaz Torres |
collection | DOAJ |
description | This paper presents the results of energetic planning phase of the management standard NC ISO 50001 implemented in a telecommunications company. It was made taking into account the requirements set by existing regulations and key issues were determined such as the institution’s policy regarding energy, scopes and limits; legal requirements were compiled as well as the functions applicable to the senior management of the company together with the work team. The scope of the research is the energy planning phase and two methodologies present in specialized literature will be applied in this area. As a result of theenergy related review the areas or equipment of significant energy use (SEnUs) of each transmission center selected were identified; potential savings and number of Energy indicators for performance evaluation were also identified. Moreover, it was estimated that measures to improve energy represent potential savings up to 30,299 CUC/ year. |
first_indexed | 2024-04-13T18:05:56Z |
format | Article |
id | doaj.art-e65bd823432641ae90cca595ea3ee047 |
institution | Directory Open Access Journal |
issn | 1815-5901 |
language | English |
last_indexed | 2024-04-13T18:05:56Z |
publishDate | 2020-09-01 |
publisher | Universidad Tecnológica de La Habana, José Antonio Echeverría |
record_format | Article |
series | Revista Científica de Ingeniería Energética |
spelling | doaj.art-e65bd823432641ae90cca595ea3ee0472022-12-22T02:36:05ZengUniversidad Tecnológica de La Habana, José Antonio EcheverríaRevista Científica de Ingeniería Energética1815-59012020-09-01413111Implementation of the energy management standard NC 50001 (up to energetic-planning phase) in a telecommunication companyYamile Díaz Torres0Mario A. Alvares Guerra Plasencia1Alejandro Valdés López2Lester Pimentel Cabrera3Onelio Castillo Barrios4Dries Haeseldonck5Universidad Carlos Rafael Rodríguez de Cienfuegos, CubaUniversidad Carlos Rafael Rodríguez de Cienfuegos, CubaUniversidad Carlos Rafael Rodríguez de Cienfuegos, CubaUniversidad Carlos Rafael Rodríguez de Cienfuegos, CubaUniversidad Carlos Rafael Rodríguez de Cienfuegos, CubaUniversity of Leuven, Ku Leuven, faculty of engineering and technology. Belgium This paper presents the results of energetic planning phase of the management standard NC ISO 50001 implemented in a telecommunications company. It was made taking into account the requirements set by existing regulations and key issues were determined such as the institution’s policy regarding energy, scopes and limits; legal requirements were compiled as well as the functions applicable to the senior management of the company together with the work team. The scope of the research is the energy planning phase and two methodologies present in specialized literature will be applied in this area. As a result of theenergy related review the areas or equipment of significant energy use (SEnUs) of each transmission center selected were identified; potential savings and number of Energy indicators for performance evaluation were also identified. Moreover, it was estimated that measures to improve energy represent potential savings up to 30,299 CUC/ year. https://rie.cujae.edu.cu/index.php/RIE/article/view/603/pdfstandard iso 50001energy planning phaseenergy efficiencybroadcast centerstransmitter. |
spellingShingle | Yamile Díaz Torres Mario A. Alvares Guerra Plasencia Alejandro Valdés López Lester Pimentel Cabrera Onelio Castillo Barrios Dries Haeseldonck Implementation of the energy management standard NC 50001 (up to energetic-planning phase) in a telecommunication company Revista Científica de Ingeniería Energética standard iso 50001 energy planning phase energy efficiency broadcast centers transmitter. |
title | Implementation of the energy management standard NC 50001 (up to energetic-planning phase) in a telecommunication company |
title_full | Implementation of the energy management standard NC 50001 (up to energetic-planning phase) in a telecommunication company |
title_fullStr | Implementation of the energy management standard NC 50001 (up to energetic-planning phase) in a telecommunication company |
title_full_unstemmed | Implementation of the energy management standard NC 50001 (up to energetic-planning phase) in a telecommunication company |
title_short | Implementation of the energy management standard NC 50001 (up to energetic-planning phase) in a telecommunication company |
title_sort | implementation of the energy management standard nc 50001 up to energetic planning phase in a telecommunication company |
topic | standard iso 50001 energy planning phase energy efficiency broadcast centers transmitter. |
url | https://rie.cujae.edu.cu/index.php/RIE/article/view/603/pdf |
work_keys_str_mv | AT yamilediaztorres implementationoftheenergymanagementstandardnc50001uptoenergeticplanningphaseinatelecommunicationcompany AT marioaalvaresguerraplasencia implementationoftheenergymanagementstandardnc50001uptoenergeticplanningphaseinatelecommunicationcompany AT alejandrovaldeslopez implementationoftheenergymanagementstandardnc50001uptoenergeticplanningphaseinatelecommunicationcompany AT lesterpimentelcabrera implementationoftheenergymanagementstandardnc50001uptoenergeticplanningphaseinatelecommunicationcompany AT oneliocastillobarrios implementationoftheenergymanagementstandardnc50001uptoenergeticplanningphaseinatelecommunicationcompany AT drieshaeseldonck implementationoftheenergymanagementstandardnc50001uptoenergeticplanningphaseinatelecommunicationcompany |