Dual-chamber versus single chamber pacemakers, a systemic review and meta-analysis on sick sinus syndrome and atrioventricular block patients
Aims: The atrioventricular block (AVB) is a conduction system problem that results from the impairment in the transmission of an impulse from the atria to the ventricle, the disease has many etiologies. This article aimed to evaluate the efficacy and safety of dual and single-chamber pacemakers in p...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2024-01-01
|
Series: | Heliyon |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2405844023110851 |
_version_ | 1797336927132712960 |
---|---|
author | Abdul Rehman Shah Syed Abdullah Akram Muhammad Shaheryar Azam Ayesha Irshad Ansari Muhammad Ali Muzammil Abdul Ahad Syed Shaheer Ahmed Syeda Javeria Zakir |
author_facet | Abdul Rehman Shah Syed Abdullah Akram Muhammad Shaheryar Azam Ayesha Irshad Ansari Muhammad Ali Muzammil Abdul Ahad Syed Shaheer Ahmed Syeda Javeria Zakir |
author_sort | Abdul Rehman Shah Syed |
collection | DOAJ |
description | Aims: The atrioventricular block (AVB) is a conduction system problem that results from the impairment in the transmission of an impulse from the atria to the ventricle, the disease has many etiologies. This article aimed to evaluate the efficacy and safety of dual and single-chamber pacemakers in patients with SSS and AVB. Methods: An electronic search of PubMed (Medline), EMBASE, and Google Scholar was performed from 2000 till August 15th, 2022. Retrieved articles were exported to Endnote Reference Library Software, where duplicate studies were removed from the list, and only articles meeting the eligibility criteria of this study were selected. RevMan 5.4 and STATA 16 software were used for the analysis. The modified Cochrane Collaboration's risk of bias and New-castle Ottawa scale were used for quality assessment of RCTs and observational studies respectively. Results: This study is composed of 8953 patients with sick-sinus syndrome and atrioventricular block. A total of thirteen outcomes are included in this meta-analysis, out of which atrial fibrillation significantly favored dual chamber [OR = 1.29; 95 % CI = 1.05–1.59; P = 0.01 I2 = 29 %] and overall complications [OR = 0.48; 95 % CI = 0.29–0.77; p = 0.03 I2 = 0 %] and pneumothorax [OR = 0.31; 95 % CI = 0.10–0.93; p = 0.04, I2 = 0 %] were satisfied by single-chamber pacing. Conclusion: This study concluded that neither single-chamber nor dual-chamber pacemakers are superior to each other, but they are unique in their own ways as the results of this study manifest remarkable reduction in atrial fibrillation rates and pneumothorax using dual-chamber and single-chamber pacemakers respectively. |
first_indexed | 2024-03-08T09:02:00Z |
format | Article |
id | doaj.art-e6e9ff394f89469cb75d89e36cb01548 |
institution | Directory Open Access Journal |
issn | 2405-8440 |
language | English |
last_indexed | 2024-03-08T09:02:00Z |
publishDate | 2024-01-01 |
publisher | Elsevier |
record_format | Article |
series | Heliyon |
spelling | doaj.art-e6e9ff394f89469cb75d89e36cb015482024-02-01T06:33:57ZengElsevierHeliyon2405-84402024-01-01101e23877Dual-chamber versus single chamber pacemakers, a systemic review and meta-analysis on sick sinus syndrome and atrioventricular block patientsAbdul Rehman Shah Syed0Abdullah Akram1Muhammad Shaheryar Azam2Ayesha Irshad Ansari3Muhammad Ali Muzammil4Abdul Ahad Syed5Shaheer Ahmed6Syeda Javeria Zakir7Corresponding author.; Dow University of Health Science (Medicine), PakistanDow University of Health Science (Medicine), PakistanDow University of Health Science (Medicine), PakistanDow University of Health Science (Medicine), PakistanDow University of Health Science (Medicine), PakistanDow University of Health Science (Medicine), PakistanDow University of Health Science (Medicine), PakistanDow University of Health Science (Medicine), PakistanAims: The atrioventricular block (AVB) is a conduction system problem that results from the impairment in the transmission of an impulse from the atria to the ventricle, the disease has many etiologies. This article aimed to evaluate the efficacy and safety of dual and single-chamber pacemakers in patients with SSS and AVB. Methods: An electronic search of PubMed (Medline), EMBASE, and Google Scholar was performed from 2000 till August 15th, 2022. Retrieved articles were exported to Endnote Reference Library Software, where duplicate studies were removed from the list, and only articles meeting the eligibility criteria of this study were selected. RevMan 5.4 and STATA 16 software were used for the analysis. The modified Cochrane Collaboration's risk of bias and New-castle Ottawa scale were used for quality assessment of RCTs and observational studies respectively. Results: This study is composed of 8953 patients with sick-sinus syndrome and atrioventricular block. A total of thirteen outcomes are included in this meta-analysis, out of which atrial fibrillation significantly favored dual chamber [OR = 1.29; 95 % CI = 1.05–1.59; P = 0.01 I2 = 29 %] and overall complications [OR = 0.48; 95 % CI = 0.29–0.77; p = 0.03 I2 = 0 %] and pneumothorax [OR = 0.31; 95 % CI = 0.10–0.93; p = 0.04, I2 = 0 %] were satisfied by single-chamber pacing. Conclusion: This study concluded that neither single-chamber nor dual-chamber pacemakers are superior to each other, but they are unique in their own ways as the results of this study manifest remarkable reduction in atrial fibrillation rates and pneumothorax using dual-chamber and single-chamber pacemakers respectively.http://www.sciencedirect.com/science/article/pii/S2405844023110851Sick-sinus syndromeAtrioventricular blockpacemakeratrial fibrillationHeart failure care |
spellingShingle | Abdul Rehman Shah Syed Abdullah Akram Muhammad Shaheryar Azam Ayesha Irshad Ansari Muhammad Ali Muzammil Abdul Ahad Syed Shaheer Ahmed Syeda Javeria Zakir Dual-chamber versus single chamber pacemakers, a systemic review and meta-analysis on sick sinus syndrome and atrioventricular block patients Heliyon Sick-sinus syndrome Atrioventricular block pacemaker atrial fibrillation Heart failure care |
title | Dual-chamber versus single chamber pacemakers, a systemic review and meta-analysis on sick sinus syndrome and atrioventricular block patients |
title_full | Dual-chamber versus single chamber pacemakers, a systemic review and meta-analysis on sick sinus syndrome and atrioventricular block patients |
title_fullStr | Dual-chamber versus single chamber pacemakers, a systemic review and meta-analysis on sick sinus syndrome and atrioventricular block patients |
title_full_unstemmed | Dual-chamber versus single chamber pacemakers, a systemic review and meta-analysis on sick sinus syndrome and atrioventricular block patients |
title_short | Dual-chamber versus single chamber pacemakers, a systemic review and meta-analysis on sick sinus syndrome and atrioventricular block patients |
title_sort | dual chamber versus single chamber pacemakers a systemic review and meta analysis on sick sinus syndrome and atrioventricular block patients |
topic | Sick-sinus syndrome Atrioventricular block pacemaker atrial fibrillation Heart failure care |
url | http://www.sciencedirect.com/science/article/pii/S2405844023110851 |
work_keys_str_mv | AT abdulrehmanshahsyed dualchamberversussinglechamberpacemakersasystemicreviewandmetaanalysisonsicksinussyndromeandatrioventricularblockpatients AT abdullahakram dualchamberversussinglechamberpacemakersasystemicreviewandmetaanalysisonsicksinussyndromeandatrioventricularblockpatients AT muhammadshaheryarazam dualchamberversussinglechamberpacemakersasystemicreviewandmetaanalysisonsicksinussyndromeandatrioventricularblockpatients AT ayeshairshadansari dualchamberversussinglechamberpacemakersasystemicreviewandmetaanalysisonsicksinussyndromeandatrioventricularblockpatients AT muhammadalimuzammil dualchamberversussinglechamberpacemakersasystemicreviewandmetaanalysisonsicksinussyndromeandatrioventricularblockpatients AT abdulahadsyed dualchamberversussinglechamberpacemakersasystemicreviewandmetaanalysisonsicksinussyndromeandatrioventricularblockpatients AT shaheerahmed dualchamberversussinglechamberpacemakersasystemicreviewandmetaanalysisonsicksinussyndromeandatrioventricularblockpatients AT syedajaveriazakir dualchamberversussinglechamberpacemakersasystemicreviewandmetaanalysisonsicksinussyndromeandatrioventricularblockpatients |