A 89 GHz Sub-harmonic Mixer for Radiometer

A hybrid integrated 89 GHz sub-harmonic mixer based on Schottky diode was proposed for meteorological monitoring radiometer. In this paper, based on the theory of millimeter wave mixing technology, a three-dimensional electromagnetic model of diode is established in the field simulation software, an...

Full description

Bibliographic Details
Main Authors: Yi-yi JIANG, Can CUI, Xi-ya GU
Format: Article
Language:zho
Published: 《光通信研究》编辑部 2022-08-01
Series:Guangtongxin yanjiu
Subjects:
Online Access:http://www.gtxyj.com.cn/thesisDetails#10.13756/j.gtxyj.2022.04.012&lang=zh
_version_ 1797986819659268096
author Yi-yi JIANG
Can CUI
Xi-ya GU
author_facet Yi-yi JIANG
Can CUI
Xi-ya GU
author_sort Yi-yi JIANG
collection DOAJ
description A hybrid integrated 89 GHz sub-harmonic mixer based on Schottky diode was proposed for meteorological monitoring radiometer. In this paper, based on the theory of millimeter wave mixing technology, a three-dimensional electromagnetic model of diode is established in the field simulation software, and a W-band 89 GHz sub-harmonic mixer is designed based on the three-dimensional electromagnetic model. The simulation and test results show that when the Local Oscillator (LO) is fixed at 45 GHz, the conversion loss is better than 14 dB from 84 to 94 GHz, and the minimum conversion loss is 9 dB. The measured results are consistent with the simulation results.
first_indexed 2024-04-11T07:39:01Z
format Article
id doaj.art-e6ea191183d04c9a9a7d784d5eb39d6d
institution Directory Open Access Journal
issn 1005-8788
language zho
last_indexed 2024-04-11T07:39:01Z
publishDate 2022-08-01
publisher 《光通信研究》编辑部
record_format Article
series Guangtongxin yanjiu
spelling doaj.art-e6ea191183d04c9a9a7d784d5eb39d6d2022-12-22T04:36:39Zzho《光通信研究》编辑部Guangtongxin yanjiu1005-87882022-08-0145862,6810.13756/j.gtxyj.2022.04.0121005-8788(2022)04-0058-05A 89 GHz Sub-harmonic Mixer for RadiometerYi-yi JIANG0Can CUI1Xi-ya GU2School of Electronic and Information Engineering, Nanjing University of Information Science and Technology, Nanjing 210044, ChinaSchool of Electronic and Information Engineering, Nanjing University of Information Science and Technology, Nanjing 210044, ChinaSchool of Electronic and Information Engineering, Nanjing University of Information Science and Technology, Nanjing 210044, ChinaA hybrid integrated 89 GHz sub-harmonic mixer based on Schottky diode was proposed for meteorological monitoring radiometer. In this paper, based on the theory of millimeter wave mixing technology, a three-dimensional electromagnetic model of diode is established in the field simulation software, and a W-band 89 GHz sub-harmonic mixer is designed based on the three-dimensional electromagnetic model. The simulation and test results show that when the Local Oscillator (LO) is fixed at 45 GHz, the conversion loss is better than 14 dB from 84 to 94 GHz, and the minimum conversion loss is 9 dB. The measured results are consistent with the simulation results.http://www.gtxyj.com.cn/thesisDetails#10.13756/j.gtxyj.2022.04.012&lang=zh89 ghzschottky diodeshybrid integrationsub-harmonic mixerconversion loss
spellingShingle Yi-yi JIANG
Can CUI
Xi-ya GU
A 89 GHz Sub-harmonic Mixer for Radiometer
Guangtongxin yanjiu
89 ghz
schottky diodes
hybrid integration
sub-harmonic mixer
conversion loss
title A 89 GHz Sub-harmonic Mixer for Radiometer
title_full A 89 GHz Sub-harmonic Mixer for Radiometer
title_fullStr A 89 GHz Sub-harmonic Mixer for Radiometer
title_full_unstemmed A 89 GHz Sub-harmonic Mixer for Radiometer
title_short A 89 GHz Sub-harmonic Mixer for Radiometer
title_sort 89 ghz sub harmonic mixer for radiometer
topic 89 ghz
schottky diodes
hybrid integration
sub-harmonic mixer
conversion loss
url http://www.gtxyj.com.cn/thesisDetails#10.13756/j.gtxyj.2022.04.012&lang=zh
work_keys_str_mv AT yiyijiang a89ghzsubharmonicmixerforradiometer
AT cancui a89ghzsubharmonicmixerforradiometer
AT xiyagu a89ghzsubharmonicmixerforradiometer
AT yiyijiang 89ghzsubharmonicmixerforradiometer
AT cancui 89ghzsubharmonicmixerforradiometer
AT xiyagu 89ghzsubharmonicmixerforradiometer