Stop using the flotation technique and start weighing salbutamol pressurised metered-dose inhalers without dose counters
Salbutamol pressurised metered-dose inhalers (pMDIs) are not equipped with dose counters outside the USA. The aim of this study was to describe a simple reproducible method for determining the number of doses remaining in a pMDI based on scale weight. With a laboratory scale, the mean weight of th...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SMW supporting association (Trägerverein Swiss Medical Weekly SMW)
2015-07-01
|
Series: | Swiss Medical Weekly |
Subjects: | |
Online Access: | https://www.smw.ch/index.php/smw/article/view/2051 |
_version_ | 1798003649413120000 |
---|---|
author | Ermindo R. Di Paolo Stéphanie Spaggiari André Pannatier Farshid Sadeghipour Isabelle Rochat Gaudenz M Hafen |
author_facet | Ermindo R. Di Paolo Stéphanie Spaggiari André Pannatier Farshid Sadeghipour Isabelle Rochat Gaudenz M Hafen |
author_sort | Ermindo R. Di Paolo |
collection | DOAJ |
description |
Salbutamol pressurised metered-dose inhalers (pMDIs) are not equipped with dose counters outside the USA. The aim of this study was to describe a simple reproducible method for determining the number of doses remaining in a pMDI based on scale weight. With a laboratory scale, the mean weight of the canisters was 28.61 ± 0.10 g after priming and 14.84 ± 0.23 g after 200 puffs. Similar results were obtained with two common digital scales. We recommend weighing salbutamol canisters on a common digital scale, and replacing an old pMDI with a new one when the weight falls to ≤15 g.
|
first_indexed | 2024-04-11T12:11:07Z |
format | Article |
id | doaj.art-e725b0da50dd4c0a80f1d5fa70431c65 |
institution | Directory Open Access Journal |
issn | 1424-3997 |
language | English |
last_indexed | 2024-04-11T12:11:07Z |
publishDate | 2015-07-01 |
publisher | SMW supporting association (Trägerverein Swiss Medical Weekly SMW) |
record_format | Article |
series | Swiss Medical Weekly |
spelling | doaj.art-e725b0da50dd4c0a80f1d5fa70431c652022-12-22T04:24:36ZengSMW supporting association (Trägerverein Swiss Medical Weekly SMW)Swiss Medical Weekly1424-39972015-07-01145313210.4414/smw.2015.14162Stop using the flotation technique and start weighing salbutamol pressurised metered-dose inhalers without dose countersErmindo R. Di PaoloStéphanie SpaggiariAndré PannatierFarshid SadeghipourIsabelle RochatGaudenz M Hafen Salbutamol pressurised metered-dose inhalers (pMDIs) are not equipped with dose counters outside the USA. The aim of this study was to describe a simple reproducible method for determining the number of doses remaining in a pMDI based on scale weight. With a laboratory scale, the mean weight of the canisters was 28.61 ± 0.10 g after priming and 14.84 ± 0.23 g after 200 puffs. Similar results were obtained with two common digital scales. We recommend weighing salbutamol canisters on a common digital scale, and replacing an old pMDI with a new one when the weight falls to ≤15 g. https://www.smw.ch/index.php/smw/article/view/2051pressurised metered-dose inhalersdose counter |
spellingShingle | Ermindo R. Di Paolo Stéphanie Spaggiari André Pannatier Farshid Sadeghipour Isabelle Rochat Gaudenz M Hafen Stop using the flotation technique and start weighing salbutamol pressurised metered-dose inhalers without dose counters Swiss Medical Weekly pressurised metered-dose inhalers dose counter |
title | Stop using the flotation technique and start weighing salbutamol pressurised metered-dose inhalers without dose counters |
title_full | Stop using the flotation technique and start weighing salbutamol pressurised metered-dose inhalers without dose counters |
title_fullStr | Stop using the flotation technique and start weighing salbutamol pressurised metered-dose inhalers without dose counters |
title_full_unstemmed | Stop using the flotation technique and start weighing salbutamol pressurised metered-dose inhalers without dose counters |
title_short | Stop using the flotation technique and start weighing salbutamol pressurised metered-dose inhalers without dose counters |
title_sort | stop using the flotation technique and start weighing salbutamol pressurised metered dose inhalers without dose counters |
topic | pressurised metered-dose inhalers dose counter |
url | https://www.smw.ch/index.php/smw/article/view/2051 |
work_keys_str_mv | AT ermindordipaolo stopusingtheflotationtechniqueandstartweighingsalbutamolpressurisedmetereddoseinhalerswithoutdosecounters AT stephaniespaggiari stopusingtheflotationtechniqueandstartweighingsalbutamolpressurisedmetereddoseinhalerswithoutdosecounters AT andrepannatier stopusingtheflotationtechniqueandstartweighingsalbutamolpressurisedmetereddoseinhalerswithoutdosecounters AT farshidsadeghipour stopusingtheflotationtechniqueandstartweighingsalbutamolpressurisedmetereddoseinhalerswithoutdosecounters AT isabellerochat stopusingtheflotationtechniqueandstartweighingsalbutamolpressurisedmetereddoseinhalerswithoutdosecounters AT gaudenzmhafen stopusingtheflotationtechniqueandstartweighingsalbutamolpressurisedmetereddoseinhalerswithoutdosecounters |