Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry
Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) wa...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Mashhad University of Medical Sciences
2010-03-01
|
Series: | Iranian Journal of Medical Physics |
Subjects: | |
Online Access: | http://ijmp.mums.ac.ir/article_7267_8ac6ee60cc124c33145ada10d55ab585.pdf |
_version_ | 1818247684937482240 |
---|---|
author | Mohammad Taghi Bahreyni Toossi Ghorban Safaeian Mohammad Hosein Bahreyni Toossi Shahram Baiani |
author_facet | Mohammad Taghi Bahreyni Toossi Ghorban Safaeian Mohammad Hosein Bahreyni Toossi Shahram Baiani |
author_sort | Mohammad Taghi Bahreyni Toossi |
collection | DOAJ |
description | Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phantom. The gel phantom was irradiated with a brachytherapy remote-afterloader unit using a cobalt-60 brachytherapy source and the test tubes were irradiated with a range of known doses with a cobalt-60 teletherapy unit. Imaging was performed with a multi-spin-echo protocol and a T2 quantitative technique using a Siemens 1.5 T MRI machine. The MRI images were transferred to a computer and then image processing was performed in the MATLAB environment to extract R2 maps of the irradiated area. Results: In this study and at the reference point, the dose deviation between the gel dosimetry and the calculated data was 4.5%. The distance to agreement (DTA) for dose profiles was 2.7 mm. Also, dose sensitivity of the MAGIC gel dosimeter was 0.693 S-1Gy-1 (R2 =0.9376). Conclusion: In this work, the data obtained from TPS calculations were found in very good agreement with the measured results provided by gel dosimetry. It was evaluated using a comparison of isodoses and dose at the reference point, and dose profile verification. It is also concluded that the gel dosimetry systems have proven to be a useful tool for dosimetry in clinical radiotherapy applications. |
first_indexed | 2024-12-12T15:08:37Z |
format | Article |
id | doaj.art-e770e4154ae041519dd409cd414da144 |
institution | Directory Open Access Journal |
issn | 2345-3672 2345-3672 |
language | English |
last_indexed | 2024-12-12T15:08:37Z |
publishDate | 2010-03-01 |
publisher | Mashhad University of Medical Sciences |
record_format | Article |
series | Iranian Journal of Medical Physics |
spelling | doaj.art-e770e4154ae041519dd409cd414da1442022-12-22T00:20:40ZengMashhad University of Medical SciencesIranian Journal of Medical Physics2345-36722345-36722010-03-017111410.22038/ijmp.2010.72677267Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel DosimetryMohammad Taghi Bahreyni Toossi0Ghorban Safaeian1Mohammad Hosein Bahreyni Toossi2Shahram Baiani3Professor, Medical Physics Research Center, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, IranM.Sc., in Medical Physics, Mashhad University of Medical Sciences, Mashhad, IranProfessor, Medical Physics Research Center, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, IranM.Sc., in Medical Engineering, Medical Physics Research Center, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, IranIntroduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phantom. The gel phantom was irradiated with a brachytherapy remote-afterloader unit using a cobalt-60 brachytherapy source and the test tubes were irradiated with a range of known doses with a cobalt-60 teletherapy unit. Imaging was performed with a multi-spin-echo protocol and a T2 quantitative technique using a Siemens 1.5 T MRI machine. The MRI images were transferred to a computer and then image processing was performed in the MATLAB environment to extract R2 maps of the irradiated area. Results: In this study and at the reference point, the dose deviation between the gel dosimetry and the calculated data was 4.5%. The distance to agreement (DTA) for dose profiles was 2.7 mm. Also, dose sensitivity of the MAGIC gel dosimeter was 0.693 S-1Gy-1 (R2 =0.9376). Conclusion: In this work, the data obtained from TPS calculations were found in very good agreement with the measured results provided by gel dosimetry. It was evaluated using a comparison of isodoses and dose at the reference point, and dose profile verification. It is also concluded that the gel dosimetry systems have proven to be a useful tool for dosimetry in clinical radiotherapy applications.http://ijmp.mums.ac.ir/article_7267_8ac6ee60cc124c33145ada10d55ab585.pdfMRI gel dosimetrygel calibrationMAGICTLDBrachytherapy |
spellingShingle | Mohammad Taghi Bahreyni Toossi Ghorban Safaeian Mohammad Hosein Bahreyni Toossi Shahram Baiani Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry Iranian Journal of Medical Physics MRI gel dosimetry gel calibration MAGIC TLD Brachytherapy |
title | Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry |
title_full | Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry |
title_fullStr | Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry |
title_full_unstemmed | Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry |
title_short | Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry |
title_sort | evaluation of dose distribution accuracy in hdr brachytherapy of esophagus cancer based on mri normoxic polymer gel dosimetry |
topic | MRI gel dosimetry gel calibration MAGIC TLD Brachytherapy |
url | http://ijmp.mums.ac.ir/article_7267_8ac6ee60cc124c33145ada10d55ab585.pdf |
work_keys_str_mv | AT mohammadtaghibahreynitoossi evaluationofdosedistributionaccuracyinhdrbrachytherapyofesophaguscancerbasedonmrinormoxicpolymergeldosimetry AT ghorbansafaeian evaluationofdosedistributionaccuracyinhdrbrachytherapyofesophaguscancerbasedonmrinormoxicpolymergeldosimetry AT mohammadhoseinbahreynitoossi evaluationofdosedistributionaccuracyinhdrbrachytherapyofesophaguscancerbasedonmrinormoxicpolymergeldosimetry AT shahrambaiani evaluationofdosedistributionaccuracyinhdrbrachytherapyofesophaguscancerbasedonmrinormoxicpolymergeldosimetry |