Development and optimization of analytical methods for the detection of 18 taste and odor compounds in drinking water utilities

Taste and odor (T&O) issues have been a major concern among drinking water utilities as source waters are becoming increasingly vulnerable to compounds released during algal blooms as well as non-algal compounds. While most of the literature focuses on the two most common T&O compounds – 2-M...

Full description

Bibliographic Details
Main Authors: Susheera (Sesha) Pochiraju, Christiane Hoppe-Jones, Craig Adams, Lauren Weinrich
Format: Article
Language:English
Published: Elsevier 2021-05-01
Series:Water Research X
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2589914721000128
_version_ 1818672290726936576
author Susheera (Sesha) Pochiraju
Christiane Hoppe-Jones
Craig Adams
Lauren Weinrich
author_facet Susheera (Sesha) Pochiraju
Christiane Hoppe-Jones
Craig Adams
Lauren Weinrich
author_sort Susheera (Sesha) Pochiraju
collection DOAJ
description Taste and odor (T&O) issues have been a major concern among drinking water utilities as source waters are becoming increasingly vulnerable to compounds released during algal blooms as well as non-algal compounds. While most of the literature focuses on the two most common T&O compounds – 2-MIB and geosmin, there are other compounds that have the potential to cause T&O events. The aim of this study was to develop an advanced analytical method using solid phase microextraction (SPME) and gas chromatography-tandem mass spectrometry (GC-MS/MS) to identify 18 T&O compounds belonging to various odor classes. The developed method was optimized for the 18 analytes and implemented to determine the holding time of the compounds in raw and treated (distribution system point-of-entry or PoE) drinking water matrices. Compounds belonging to certain classes such as pyrazines and anisoles were found to be “stable” (< 30% loss) in all tested waters for up to two weeks, while aldehydes, ketones, esters and alkyl sulfides showed > 30% loss within 96 h in raw water. Preservation of samples at low pH (< 2) using hydrochloric acid increased the holding times and reduced losses within 96 h for aldehydes, ketones and esters. The paper also discusses the occurrence of these compounds with water utilities from the Midwest and Eastern US during the summer months. The study detected eight T&O compounds - 2-MIB, geosmin, β-cyclocitral, β-ionone, hexanal, indole, dimethyl disulfide and dimethyl trisulfide. While five compounds were detected above their threshold concentrations in the raw water, two of them (2-MIB and geosmin) were detected above threshold in the PoE samples.
first_indexed 2024-12-17T07:37:33Z
format Article
id doaj.art-e7d43a14cb454f909a7c06eb3a007fb0
institution Directory Open Access Journal
issn 2589-9147
language English
last_indexed 2024-12-17T07:37:33Z
publishDate 2021-05-01
publisher Elsevier
record_format Article
series Water Research X
spelling doaj.art-e7d43a14cb454f909a7c06eb3a007fb02022-12-21T21:58:17ZengElsevierWater Research X2589-91472021-05-0111100099Development and optimization of analytical methods for the detection of 18 taste and odor compounds in drinking water utilitiesSusheera (Sesha) Pochiraju0Christiane Hoppe-Jones1Craig Adams2Lauren Weinrich3Saint Louis University, St. Louis, MO, 63103, USA; American Water, Belleville, IL, 62220, USAAmerican Water, Belleville, IL, 62220, USASaint Louis University, St. Louis, MO, 63103, USAAmerican Water, Camden, NJ, 08102, USA; Corresponding author.Taste and odor (T&O) issues have been a major concern among drinking water utilities as source waters are becoming increasingly vulnerable to compounds released during algal blooms as well as non-algal compounds. While most of the literature focuses on the two most common T&O compounds – 2-MIB and geosmin, there are other compounds that have the potential to cause T&O events. The aim of this study was to develop an advanced analytical method using solid phase microextraction (SPME) and gas chromatography-tandem mass spectrometry (GC-MS/MS) to identify 18 T&O compounds belonging to various odor classes. The developed method was optimized for the 18 analytes and implemented to determine the holding time of the compounds in raw and treated (distribution system point-of-entry or PoE) drinking water matrices. Compounds belonging to certain classes such as pyrazines and anisoles were found to be “stable” (< 30% loss) in all tested waters for up to two weeks, while aldehydes, ketones, esters and alkyl sulfides showed > 30% loss within 96 h in raw water. Preservation of samples at low pH (< 2) using hydrochloric acid increased the holding times and reduced losses within 96 h for aldehydes, ketones and esters. The paper also discusses the occurrence of these compounds with water utilities from the Midwest and Eastern US during the summer months. The study detected eight T&O compounds - 2-MIB, geosmin, β-cyclocitral, β-ionone, hexanal, indole, dimethyl disulfide and dimethyl trisulfide. While five compounds were detected above their threshold concentrations in the raw water, two of them (2-MIB and geosmin) were detected above threshold in the PoE samples.http://www.sciencedirect.com/science/article/pii/S2589914721000128Taste and odor compoundsDrinking waterSPMEGC-MS/MSHolding timeT&O occurrence
spellingShingle Susheera (Sesha) Pochiraju
Christiane Hoppe-Jones
Craig Adams
Lauren Weinrich
Development and optimization of analytical methods for the detection of 18 taste and odor compounds in drinking water utilities
Water Research X
Taste and odor compounds
Drinking water
SPME
GC-MS/MS
Holding time
T&O occurrence
title Development and optimization of analytical methods for the detection of 18 taste and odor compounds in drinking water utilities
title_full Development and optimization of analytical methods for the detection of 18 taste and odor compounds in drinking water utilities
title_fullStr Development and optimization of analytical methods for the detection of 18 taste and odor compounds in drinking water utilities
title_full_unstemmed Development and optimization of analytical methods for the detection of 18 taste and odor compounds in drinking water utilities
title_short Development and optimization of analytical methods for the detection of 18 taste and odor compounds in drinking water utilities
title_sort development and optimization of analytical methods for the detection of 18 taste and odor compounds in drinking water utilities
topic Taste and odor compounds
Drinking water
SPME
GC-MS/MS
Holding time
T&O occurrence
url http://www.sciencedirect.com/science/article/pii/S2589914721000128
work_keys_str_mv AT susheeraseshapochiraju developmentandoptimizationofanalyticalmethodsforthedetectionof18tasteandodorcompoundsindrinkingwaterutilities
AT christianehoppejones developmentandoptimizationofanalyticalmethodsforthedetectionof18tasteandodorcompoundsindrinkingwaterutilities
AT craigadams developmentandoptimizationofanalyticalmethodsforthedetectionof18tasteandodorcompoundsindrinkingwaterutilities
AT laurenweinrich developmentandoptimizationofanalyticalmethodsforthedetectionof18tasteandodorcompoundsindrinkingwaterutilities