Improved Bond Stress-Slip Relationships for Carbon Fibre-Reinforced Polymer-Strengthened Masonry Triplets

Carbon fibre-reinforced polymer (CFRP) emerges as a viable solution for reinforcing unreinforced masonry (URM) walls subjected to shear loads. While masonry structures are straightforward to construct, the complexity of the construction materials, especially in terms of their mechanical properties,...

Full description

Bibliographic Details
Main Authors: Seyyed Motasam Hashemi, Ashraf Ayoub
Format: Article
Language:English
Published: MDPI AG 2024-01-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/14/1/257
_version_ 1797339975602143232
author Seyyed Motasam Hashemi
Ashraf Ayoub
author_facet Seyyed Motasam Hashemi
Ashraf Ayoub
author_sort Seyyed Motasam Hashemi
collection DOAJ
description Carbon fibre-reinforced polymer (CFRP) emerges as a viable solution for reinforcing unreinforced masonry (URM) walls subjected to shear loads. While masonry structures are straightforward to construct, the complexity of the construction materials, especially in terms of their mechanical properties, poses challenges for numerical studies of their structural behaviour. Walls, being fundamental components in masonry construction, play a crucial role in transferring both horizontal and vertical lateral forces. This study investigates the enhancement of masonry wall behaviour through the reinforcement of CFRP. CFRP reinforcement increases ductility and strength, reducing the risk of failure under shear conditions. Additionally, CFRP composites present a practical solution to strengthening masonry structures compared to traditional reinforcement. However, brick, mortar, and CFRP have not been thoroughly investigated. Experimental tests on the bond behaviour of different configurations of CFRP-retrofitted masonry triplets have not been performed before and are therefore presented in this paper. Triplet specimens, comprising three bricks and two mortar joints, both with and without CFRP strengthening, were subjected to bond testing. The study affirms that masonry triplets strengthened with CFRP under shear loads exhibit strength levels at least four to six times greater than those without CFRP. The experimental work was carried out with eight different CFRP configurations on triplet masonry, and each test was repeated four times. Further, the bond stress-slip relationship in the case of masonry triplets with and without CFRP was predicted with new mathematical equations based on the conducted test results. These equations were included in the commercial finite element software ANSYS and used to conduct simulations of CFRP-reinforced masonry triplets. The numerical results indicate good agreement between the finite element model and the test results. The outcome of this research improves the current knowledge on the use of CFRP to reinforce masonry walls with brick and mortar, which will contribute to the understanding of the effect of CFRP on masonry structures.
first_indexed 2024-03-08T09:56:20Z
format Article
id doaj.art-e7fddfd8d55e4e67b2790db950f16385
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-08T09:56:20Z
publishDate 2024-01-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-e7fddfd8d55e4e67b2790db950f163852024-01-29T13:49:33ZengMDPI AGBuildings2075-53092024-01-0114125710.3390/buildings14010257Improved Bond Stress-Slip Relationships for Carbon Fibre-Reinforced Polymer-Strengthened Masonry TripletsSeyyed Motasam Hashemi0Ashraf Ayoub1School of Science & Technology, City, University of London, Northampton Square, London EC1V 0HB, UKSchool of Science & Technology, City, University of London, Northampton Square, London EC1V 0HB, UKCarbon fibre-reinforced polymer (CFRP) emerges as a viable solution for reinforcing unreinforced masonry (URM) walls subjected to shear loads. While masonry structures are straightforward to construct, the complexity of the construction materials, especially in terms of their mechanical properties, poses challenges for numerical studies of their structural behaviour. Walls, being fundamental components in masonry construction, play a crucial role in transferring both horizontal and vertical lateral forces. This study investigates the enhancement of masonry wall behaviour through the reinforcement of CFRP. CFRP reinforcement increases ductility and strength, reducing the risk of failure under shear conditions. Additionally, CFRP composites present a practical solution to strengthening masonry structures compared to traditional reinforcement. However, brick, mortar, and CFRP have not been thoroughly investigated. Experimental tests on the bond behaviour of different configurations of CFRP-retrofitted masonry triplets have not been performed before and are therefore presented in this paper. Triplet specimens, comprising three bricks and two mortar joints, both with and without CFRP strengthening, were subjected to bond testing. The study affirms that masonry triplets strengthened with CFRP under shear loads exhibit strength levels at least four to six times greater than those without CFRP. The experimental work was carried out with eight different CFRP configurations on triplet masonry, and each test was repeated four times. Further, the bond stress-slip relationship in the case of masonry triplets with and without CFRP was predicted with new mathematical equations based on the conducted test results. These equations were included in the commercial finite element software ANSYS and used to conduct simulations of CFRP-reinforced masonry triplets. The numerical results indicate good agreement between the finite element model and the test results. The outcome of this research improves the current knowledge on the use of CFRP to reinforce masonry walls with brick and mortar, which will contribute to the understanding of the effect of CFRP on masonry structures.https://www.mdpi.com/2075-5309/14/1/257unreinforced masonryfibre-reinforced polymerbond stress-slipinterface behaviourmasonry tripletsshear load
spellingShingle Seyyed Motasam Hashemi
Ashraf Ayoub
Improved Bond Stress-Slip Relationships for Carbon Fibre-Reinforced Polymer-Strengthened Masonry Triplets
Buildings
unreinforced masonry
fibre-reinforced polymer
bond stress-slip
interface behaviour
masonry triplets
shear load
title Improved Bond Stress-Slip Relationships for Carbon Fibre-Reinforced Polymer-Strengthened Masonry Triplets
title_full Improved Bond Stress-Slip Relationships for Carbon Fibre-Reinforced Polymer-Strengthened Masonry Triplets
title_fullStr Improved Bond Stress-Slip Relationships for Carbon Fibre-Reinforced Polymer-Strengthened Masonry Triplets
title_full_unstemmed Improved Bond Stress-Slip Relationships for Carbon Fibre-Reinforced Polymer-Strengthened Masonry Triplets
title_short Improved Bond Stress-Slip Relationships for Carbon Fibre-Reinforced Polymer-Strengthened Masonry Triplets
title_sort improved bond stress slip relationships for carbon fibre reinforced polymer strengthened masonry triplets
topic unreinforced masonry
fibre-reinforced polymer
bond stress-slip
interface behaviour
masonry triplets
shear load
url https://www.mdpi.com/2075-5309/14/1/257
work_keys_str_mv AT seyyedmotasamhashemi improvedbondstresssliprelationshipsforcarbonfibrereinforcedpolymerstrengthenedmasonrytriplets
AT ashrafayoub improvedbondstresssliprelationshipsforcarbonfibrereinforcedpolymerstrengthenedmasonrytriplets