Thermal evaluation and biological control of cooling towers
The cooling water system of the Amuay refinery consists of two induced draft and cross flow cooling water towers, seven pumps and four supply pipes and their returns. This system supplies cooling water to the hydrotreatment complex, to the pipestill N° 5 and to the surface condensers of the power pl...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidad del Zulia
2010-12-01
|
Series: | Revista Técnica de la Facultad de Ingeniería |
Subjects: | |
Online Access: | https://www.produccioncientificaluz.org/index.php/tecnica/article/view/5630 |
_version_ | 1811188697184337920 |
---|---|
author | Hernán Trujillo Javier Colina Jorge Sánchez |
author_facet | Hernán Trujillo Javier Colina Jorge Sánchez |
author_sort | Hernán Trujillo |
collection | DOAJ |
description | The cooling water system of the Amuay refinery consists of two induced draft and cross flow cooling water towers, seven pumps and four supply pipes and their returns. This system supplies cooling water to the hydrotreatment complex, to the pipestill N° 5 and to the surface condensers of the power plant turbogenerators. This cooling water system showed constraints in the tower's cooling capacity to meet the design conditions, due mainly to a biological growth inside the towers, also increasing the need for cleaning more frequently the surface condensers of the power plant turbogenerators, indicating that the microbiological control was not suitable. In this study a thermal evaluation was performed to the towers, before and after the application of a biological control program by means of biocides and biodispersants, to decrease the growth of microorganisms. The towers were operating at 83% of their design cooling capacity, mainly because of the growth of algae inside them. After implementing the microbiological program, the cooling efficiency increased to 91%. Likewise, the heat transfer in the surface condensers of the power plant turbogenerators also increased.
|
first_indexed | 2024-04-11T14:23:51Z |
format | Article |
id | doaj.art-e82ec32e91f14dc592fea143d0c7d4e3 |
institution | Directory Open Access Journal |
issn | 0254-0770 2477-9377 |
language | English |
last_indexed | 2024-04-11T14:23:51Z |
publishDate | 2010-12-01 |
publisher | Universidad del Zulia |
record_format | Article |
series | Revista Técnica de la Facultad de Ingeniería |
spelling | doaj.art-e82ec32e91f14dc592fea143d0c7d4e32022-12-22T04:18:59ZengUniversidad del ZuliaRevista Técnica de la Facultad de Ingeniería0254-07702477-93772010-12-01222Thermal evaluation and biological control of cooling towersHernán Trujillo0Javier Colina1Jorge Sánchez2Refinería de Amuay-VenezuelaRefinería de Amuay-VenezuelaUniversidad del Zulia-VenezuelaThe cooling water system of the Amuay refinery consists of two induced draft and cross flow cooling water towers, seven pumps and four supply pipes and their returns. This system supplies cooling water to the hydrotreatment complex, to the pipestill N° 5 and to the surface condensers of the power plant turbogenerators. This cooling water system showed constraints in the tower's cooling capacity to meet the design conditions, due mainly to a biological growth inside the towers, also increasing the need for cleaning more frequently the surface condensers of the power plant turbogenerators, indicating that the microbiological control was not suitable. In this study a thermal evaluation was performed to the towers, before and after the application of a biological control program by means of biocides and biodispersants, to decrease the growth of microorganisms. The towers were operating at 83% of their design cooling capacity, mainly because of the growth of algae inside them. After implementing the microbiological program, the cooling efficiency increased to 91%. Likewise, the heat transfer in the surface condensers of the power plant turbogenerators also increased. https://www.produccioncientificaluz.org/index.php/tecnica/article/view/5630cooling towerthermal evaluationbiological control |
spellingShingle | Hernán Trujillo Javier Colina Jorge Sánchez Thermal evaluation and biological control of cooling towers Revista Técnica de la Facultad de Ingeniería cooling tower thermal evaluation biological control |
title | Thermal evaluation and biological control of cooling towers |
title_full | Thermal evaluation and biological control of cooling towers |
title_fullStr | Thermal evaluation and biological control of cooling towers |
title_full_unstemmed | Thermal evaluation and biological control of cooling towers |
title_short | Thermal evaluation and biological control of cooling towers |
title_sort | thermal evaluation and biological control of cooling towers |
topic | cooling tower thermal evaluation biological control |
url | https://www.produccioncientificaluz.org/index.php/tecnica/article/view/5630 |
work_keys_str_mv | AT hernantrujillo thermalevaluationandbiologicalcontrolofcoolingtowers AT javiercolina thermalevaluationandbiologicalcontrolofcoolingtowers AT jorgesanchez thermalevaluationandbiologicalcontrolofcoolingtowers |