Comparison of Different Magnesium Hydroxide Coatings Applied on Concrete Substrates (Sewer Pipes) for Protection against Bio-Corrosion

Several coatings and linings have been examined and used for the protection of sewer concrete pipes, against mainly biogenic-provoked corrosion due to the production of bio-sulfuric acid, leading to the degradation of the pipes’ structure and eventually, to their collapse and need for costly replace...

Full description

Bibliographic Details
Main Authors: Domna Merachtsaki, Eirini-Chrysanthi Tsardaka, Eleftherios K. Anastasiou, Haris Yiannoulakis, Anastasios Zouboulis
Format: Article
Language:English
Published: MDPI AG 2021-04-01
Series:Water
Subjects:
Online Access:https://www.mdpi.com/2073-4441/13/9/1227
_version_ 1797535877947195392
author Domna Merachtsaki
Eirini-Chrysanthi Tsardaka
Eleftherios K. Anastasiou
Haris Yiannoulakis
Anastasios Zouboulis
author_facet Domna Merachtsaki
Eirini-Chrysanthi Tsardaka
Eleftherios K. Anastasiou
Haris Yiannoulakis
Anastasios Zouboulis
author_sort Domna Merachtsaki
collection DOAJ
description Several coatings and linings have been examined and used for the protection of sewer concrete pipes, against mainly biogenic-provoked corrosion due to the production of bio-sulfuric acid, leading to the degradation of the pipes’ structure and eventually, to their collapse and need for costly replacement. This study aimed to examine the potential differences between five different magnesium hydroxide coatings, prepared from powders presenting different purity, surface area and pore size distribution, when applied as corrosion protection agents. These coatings were tested by using accelerated sulfuric acid spraying tests, both in dry and wet coating conditions. The coating adhesion ability and their microstructure were examined by the application of pull-off measurements and of SEM analysis, respectively and were found to present certain differences, regarding the adhesion ability and the surface morphologies. During the acid spraying procedure, the surface pH and the mass change of coated concrete specimens were recorded daily. The surface pH was reduced towards acidic values and the mass reduction approached almost −20% in comparison with the initial coating mass for certain cases. Additionally, the hardness and roughness of concrete surface under the coating layer (i.e., the interface between the coating and the surface) after four days of acid spraying, exhibited much smaller changes (due to protection) in contrast to the uncoated concrete specimens (used as blank/comparison experiments), which were found to be highly affected/corroded. The formation of concrete corrosion and coating by-products, as noticed after the respective chemical reactions, was recorded by X-ray diffraction (XRD) measurements and the respective quantification of obtained results. In all the coated specimens only very small amounts of the major by-product (gypsum) was observed, indicating that the concrete surface was sufficiently protected from sulfuric acid attack.
first_indexed 2024-03-10T11:51:36Z
format Article
id doaj.art-e838bd2af8aa4b0a8bedbd1ca3e304a2
institution Directory Open Access Journal
issn 2073-4441
language English
last_indexed 2024-03-10T11:51:36Z
publishDate 2021-04-01
publisher MDPI AG
record_format Article
series Water
spelling doaj.art-e838bd2af8aa4b0a8bedbd1ca3e304a22023-11-21T17:40:12ZengMDPI AGWater2073-44412021-04-01139122710.3390/w13091227Comparison of Different Magnesium Hydroxide Coatings Applied on Concrete Substrates (Sewer Pipes) for Protection against Bio-CorrosionDomna Merachtsaki0Eirini-Chrysanthi Tsardaka1Eleftherios K. Anastasiou2Haris Yiannoulakis3Anastasios Zouboulis4Laboratory of Chemical and Environmental Technology, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, GreeceLaboratory of Building Materials, Department of Civil Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, GreeceLaboratory of Building Materials, Department of Civil Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, GreeceResearch and Development Center, Grecian Magnesite S.A., 57006 Thessaloniki, GreeceLaboratory of Chemical and Environmental Technology, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, GreeceSeveral coatings and linings have been examined and used for the protection of sewer concrete pipes, against mainly biogenic-provoked corrosion due to the production of bio-sulfuric acid, leading to the degradation of the pipes’ structure and eventually, to their collapse and need for costly replacement. This study aimed to examine the potential differences between five different magnesium hydroxide coatings, prepared from powders presenting different purity, surface area and pore size distribution, when applied as corrosion protection agents. These coatings were tested by using accelerated sulfuric acid spraying tests, both in dry and wet coating conditions. The coating adhesion ability and their microstructure were examined by the application of pull-off measurements and of SEM analysis, respectively and were found to present certain differences, regarding the adhesion ability and the surface morphologies. During the acid spraying procedure, the surface pH and the mass change of coated concrete specimens were recorded daily. The surface pH was reduced towards acidic values and the mass reduction approached almost −20% in comparison with the initial coating mass for certain cases. Additionally, the hardness and roughness of concrete surface under the coating layer (i.e., the interface between the coating and the surface) after four days of acid spraying, exhibited much smaller changes (due to protection) in contrast to the uncoated concrete specimens (used as blank/comparison experiments), which were found to be highly affected/corroded. The formation of concrete corrosion and coating by-products, as noticed after the respective chemical reactions, was recorded by X-ray diffraction (XRD) measurements and the respective quantification of obtained results. In all the coated specimens only very small amounts of the major by-product (gypsum) was observed, indicating that the concrete surface was sufficiently protected from sulfuric acid attack.https://www.mdpi.com/2073-4441/13/9/1227concrete corrosion and controlmagnesium hydroxide coatingssewerage pipe systemsacid spraying test
spellingShingle Domna Merachtsaki
Eirini-Chrysanthi Tsardaka
Eleftherios K. Anastasiou
Haris Yiannoulakis
Anastasios Zouboulis
Comparison of Different Magnesium Hydroxide Coatings Applied on Concrete Substrates (Sewer Pipes) for Protection against Bio-Corrosion
Water
concrete corrosion and control
magnesium hydroxide coatings
sewerage pipe systems
acid spraying test
title Comparison of Different Magnesium Hydroxide Coatings Applied on Concrete Substrates (Sewer Pipes) for Protection against Bio-Corrosion
title_full Comparison of Different Magnesium Hydroxide Coatings Applied on Concrete Substrates (Sewer Pipes) for Protection against Bio-Corrosion
title_fullStr Comparison of Different Magnesium Hydroxide Coatings Applied on Concrete Substrates (Sewer Pipes) for Protection against Bio-Corrosion
title_full_unstemmed Comparison of Different Magnesium Hydroxide Coatings Applied on Concrete Substrates (Sewer Pipes) for Protection against Bio-Corrosion
title_short Comparison of Different Magnesium Hydroxide Coatings Applied on Concrete Substrates (Sewer Pipes) for Protection against Bio-Corrosion
title_sort comparison of different magnesium hydroxide coatings applied on concrete substrates sewer pipes for protection against bio corrosion
topic concrete corrosion and control
magnesium hydroxide coatings
sewerage pipe systems
acid spraying test
url https://www.mdpi.com/2073-4441/13/9/1227
work_keys_str_mv AT domnamerachtsaki comparisonofdifferentmagnesiumhydroxidecoatingsappliedonconcretesubstratessewerpipesforprotectionagainstbiocorrosion
AT eirinichrysanthitsardaka comparisonofdifferentmagnesiumhydroxidecoatingsappliedonconcretesubstratessewerpipesforprotectionagainstbiocorrosion
AT eleftherioskanastasiou comparisonofdifferentmagnesiumhydroxidecoatingsappliedonconcretesubstratessewerpipesforprotectionagainstbiocorrosion
AT harisyiannoulakis comparisonofdifferentmagnesiumhydroxidecoatingsappliedonconcretesubstratessewerpipesforprotectionagainstbiocorrosion
AT anastasioszouboulis comparisonofdifferentmagnesiumhydroxidecoatingsappliedonconcretesubstratessewerpipesforprotectionagainstbiocorrosion