Investigation of Microclimate Parameter Assurance in Schools with Natural Ventilation Systems

Slow population growth has limited the construction of new schools, leading to the renovation of existing buildings to achieve energy efficiency goals. While improvements are made to thermal insulation, heating and ventilation systems often remain outdated, presenting challenges in maintaining indoo...

Full description

Bibliographic Details
Main Authors: Tomas Makaveckas, Raimondas Bliūdžius, Sigita Alavočienė, Valdas Paukštys, Ingrida Brazionienė
Format: Article
Language:English
Published: MDPI AG 2023-07-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/13/7/1807
_version_ 1797589996073385984
author Tomas Makaveckas
Raimondas Bliūdžius
Sigita Alavočienė
Valdas Paukštys
Ingrida Brazionienė
author_facet Tomas Makaveckas
Raimondas Bliūdžius
Sigita Alavočienė
Valdas Paukštys
Ingrida Brazionienė
author_sort Tomas Makaveckas
collection DOAJ
description Slow population growth has limited the construction of new schools, leading to the renovation of existing buildings to achieve energy efficiency goals. While improvements are made to thermal insulation, heating and ventilation systems often remain outdated, presenting challenges in maintaining indoor air quality (IAQ) in schools, where children spend a significant amount of time in densely populated classrooms, and whose health is more affected by IAQ than that of adults. Therefore, this study assessed the possibilities to achieve IAQ requirements in schools ventilated by opening the windows by monitoring the carbon dioxide (CO<sub>2</sub>) concentration, temperature, and relative humidity (RH) fluctuation. The results of the study have shown that it is not feasible to achieve the defined IAQ parameters in classrooms through window opening alone. The measured CO<sub>2</sub> concentration during lessons in many cases exceeded the limit value of 1000 ppm and did not decrease to ambient levels when the windows were opened during the break. Additionally, the internal air temperature dropped below the normative when lessons started, and RH was significantly below the recommended minimum value on all days. It was also found that the use of thermal energy decreases evenly because of inefficient air change leaving no direct economic leverage for the installation of efficient ventilation systems.
first_indexed 2024-03-11T01:14:06Z
format Article
id doaj.art-e8d11dac1bfa472799f66a9e5d473597
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-11T01:14:06Z
publishDate 2023-07-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-e8d11dac1bfa472799f66a9e5d4735972023-11-18T18:39:14ZengMDPI AGBuildings2075-53092023-07-01137180710.3390/buildings13071807Investigation of Microclimate Parameter Assurance in Schools with Natural Ventilation SystemsTomas Makaveckas0Raimondas Bliūdžius1Sigita Alavočienė2Valdas Paukštys3Ingrida Brazionienė4Alytus College, Studentu St. 17, LT-62252 Alytus, LithuaniaInstitute of Architecture and Construction, Kaunas University of Technology, Tunelio 60, LT-44405 Kaunas, LithuaniaAlytus College, Studentu St. 17, LT-62252 Alytus, LithuaniaInstitute of Architecture and Construction, Kaunas University of Technology, Tunelio 60, LT-44405 Kaunas, LithuaniaAlytus College, Studentu St. 17, LT-62252 Alytus, LithuaniaSlow population growth has limited the construction of new schools, leading to the renovation of existing buildings to achieve energy efficiency goals. While improvements are made to thermal insulation, heating and ventilation systems often remain outdated, presenting challenges in maintaining indoor air quality (IAQ) in schools, where children spend a significant amount of time in densely populated classrooms, and whose health is more affected by IAQ than that of adults. Therefore, this study assessed the possibilities to achieve IAQ requirements in schools ventilated by opening the windows by monitoring the carbon dioxide (CO<sub>2</sub>) concentration, temperature, and relative humidity (RH) fluctuation. The results of the study have shown that it is not feasible to achieve the defined IAQ parameters in classrooms through window opening alone. The measured CO<sub>2</sub> concentration during lessons in many cases exceeded the limit value of 1000 ppm and did not decrease to ambient levels when the windows were opened during the break. Additionally, the internal air temperature dropped below the normative when lessons started, and RH was significantly below the recommended minimum value on all days. It was also found that the use of thermal energy decreases evenly because of inefficient air change leaving no direct economic leverage for the installation of efficient ventilation systems.https://www.mdpi.com/2075-5309/13/7/1807indoor air qualityindoor air exchangeschool ventilationCO<sub>2</sub> monitoringtemperature/humidity fluctuations
spellingShingle Tomas Makaveckas
Raimondas Bliūdžius
Sigita Alavočienė
Valdas Paukštys
Ingrida Brazionienė
Investigation of Microclimate Parameter Assurance in Schools with Natural Ventilation Systems
Buildings
indoor air quality
indoor air exchange
school ventilation
CO<sub>2</sub> monitoring
temperature/humidity fluctuations
title Investigation of Microclimate Parameter Assurance in Schools with Natural Ventilation Systems
title_full Investigation of Microclimate Parameter Assurance in Schools with Natural Ventilation Systems
title_fullStr Investigation of Microclimate Parameter Assurance in Schools with Natural Ventilation Systems
title_full_unstemmed Investigation of Microclimate Parameter Assurance in Schools with Natural Ventilation Systems
title_short Investigation of Microclimate Parameter Assurance in Schools with Natural Ventilation Systems
title_sort investigation of microclimate parameter assurance in schools with natural ventilation systems
topic indoor air quality
indoor air exchange
school ventilation
CO<sub>2</sub> monitoring
temperature/humidity fluctuations
url https://www.mdpi.com/2075-5309/13/7/1807
work_keys_str_mv AT tomasmakaveckas investigationofmicroclimateparameterassuranceinschoolswithnaturalventilationsystems
AT raimondasbliudzius investigationofmicroclimateparameterassuranceinschoolswithnaturalventilationsystems
AT sigitaalavociene investigationofmicroclimateparameterassuranceinschoolswithnaturalventilationsystems
AT valdaspaukstys investigationofmicroclimateparameterassuranceinschoolswithnaturalventilationsystems
AT ingridabrazioniene investigationofmicroclimateparameterassuranceinschoolswithnaturalventilationsystems