What Is the Best Vancomycin Therapeutic Drug Monitoring Parameter to Assess Efficacy? A Critical Review of Experimental Data and Assessment of the Need for Individual Patient Minimum Inhibitory Concentration Value

Therapeutic drug monitoring is recommended for the use of vancomycin, but a recent widely publicized US medical society consensus statement has changed the suggested optimal method(s) of dose adjustment. Specifically, 24 h area under the curve (AUC<sub>24</sub>)-based monitoring is has b...

Full description

Bibliographic Details
Main Author: Bruce R. Dalton
Format: Article
Language:English
Published: MDPI AG 2023-02-01
Series:Microorganisms
Subjects:
Online Access:https://www.mdpi.com/2076-2607/11/3/567
_version_ 1797436304076570624
author Bruce R. Dalton
author_facet Bruce R. Dalton
author_sort Bruce R. Dalton
collection DOAJ
description Therapeutic drug monitoring is recommended for the use of vancomycin, but a recent widely publicized US medical society consensus statement has changed the suggested optimal method(s) of dose adjustment. Specifically, 24 h area under the curve (AUC<sub>24</sub>)-based monitoring is has been recommended for vancomycin in preference to monitoring of trough concentrations. One reason cited for this change is the claim that AUC<sub>24</sub> is a superior correlate to efficacy than trough (Cmin). Evidence from a number of retrospective analyses have been critically reviewed and determined to have weaknesses. This narrative review focuses on the experimental studies performed in vivo in animal models of infection and in vitro to determine the extent to which these data may provide a compelling distinction between pharmacokinetic/pharmacodynamics (PKPD) parameters that may translate to clinical use in therapeutic drug monitoring. Animal in vivo studies have been presented at conferences, but no original peer reviewed studies could be found that compare various PKPD parameters. These conference proceeding findings were supportive but unconvincing, even though they were favorably presented subsequently in review articles and clinical practice guidelines. In vitro data are somewhat conflicting, but the range of concentrations may play a role in the discrepancies found. It has been suggested that MIC may be assumed to have a value of 1 mg/L; however, it can be demonstrated that this assumption may lead to considerable discrepancy from results with an actual MIC value. The AUC<sub>24</sub> parameter has been weighed against the percentage of time above the MIC (%T > MIC) as a comparative PKPD parameter, yet this may be an inappropriate comparison for vancomycin since all clinically useful dosing provides 100% T > MIC. Regardless, there is a distinction between clinical TDM parameters and PKPD parameters, so, in practice, the change to AUC<sub>24</sub>:MIC based on animal experiments and in vitro evidence for vancomycin may be premature.
first_indexed 2024-03-09T11:00:42Z
format Article
id doaj.art-e8fbc82f1f7f4d918ea6f49573315dca
institution Directory Open Access Journal
issn 2076-2607
language English
last_indexed 2024-03-09T11:00:42Z
publishDate 2023-02-01
publisher MDPI AG
record_format Article
series Microorganisms
spelling doaj.art-e8fbc82f1f7f4d918ea6f49573315dca2023-12-01T01:20:21ZengMDPI AGMicroorganisms2076-26072023-02-0111356710.3390/microorganisms11030567What Is the Best Vancomycin Therapeutic Drug Monitoring Parameter to Assess Efficacy? A Critical Review of Experimental Data and Assessment of the Need for Individual Patient Minimum Inhibitory Concentration ValueBruce R. Dalton0Pharmacy Department, Alberta Health Services, Calgary, AB T2N 2T9, CanadaTherapeutic drug monitoring is recommended for the use of vancomycin, but a recent widely publicized US medical society consensus statement has changed the suggested optimal method(s) of dose adjustment. Specifically, 24 h area under the curve (AUC<sub>24</sub>)-based monitoring is has been recommended for vancomycin in preference to monitoring of trough concentrations. One reason cited for this change is the claim that AUC<sub>24</sub> is a superior correlate to efficacy than trough (Cmin). Evidence from a number of retrospective analyses have been critically reviewed and determined to have weaknesses. This narrative review focuses on the experimental studies performed in vivo in animal models of infection and in vitro to determine the extent to which these data may provide a compelling distinction between pharmacokinetic/pharmacodynamics (PKPD) parameters that may translate to clinical use in therapeutic drug monitoring. Animal in vivo studies have been presented at conferences, but no original peer reviewed studies could be found that compare various PKPD parameters. These conference proceeding findings were supportive but unconvincing, even though they were favorably presented subsequently in review articles and clinical practice guidelines. In vitro data are somewhat conflicting, but the range of concentrations may play a role in the discrepancies found. It has been suggested that MIC may be assumed to have a value of 1 mg/L; however, it can be demonstrated that this assumption may lead to considerable discrepancy from results with an actual MIC value. The AUC<sub>24</sub> parameter has been weighed against the percentage of time above the MIC (%T > MIC) as a comparative PKPD parameter, yet this may be an inappropriate comparison for vancomycin since all clinically useful dosing provides 100% T > MIC. Regardless, there is a distinction between clinical TDM parameters and PKPD parameters, so, in practice, the change to AUC<sub>24</sub>:MIC based on animal experiments and in vitro evidence for vancomycin may be premature.https://www.mdpi.com/2076-2607/11/3/567vancomycinpharmacokineticspharmacodynamicstherapeutic drug monitoring
spellingShingle Bruce R. Dalton
What Is the Best Vancomycin Therapeutic Drug Monitoring Parameter to Assess Efficacy? A Critical Review of Experimental Data and Assessment of the Need for Individual Patient Minimum Inhibitory Concentration Value
Microorganisms
vancomycin
pharmacokinetics
pharmacodynamics
therapeutic drug monitoring
title What Is the Best Vancomycin Therapeutic Drug Monitoring Parameter to Assess Efficacy? A Critical Review of Experimental Data and Assessment of the Need for Individual Patient Minimum Inhibitory Concentration Value
title_full What Is the Best Vancomycin Therapeutic Drug Monitoring Parameter to Assess Efficacy? A Critical Review of Experimental Data and Assessment of the Need for Individual Patient Minimum Inhibitory Concentration Value
title_fullStr What Is the Best Vancomycin Therapeutic Drug Monitoring Parameter to Assess Efficacy? A Critical Review of Experimental Data and Assessment of the Need for Individual Patient Minimum Inhibitory Concentration Value
title_full_unstemmed What Is the Best Vancomycin Therapeutic Drug Monitoring Parameter to Assess Efficacy? A Critical Review of Experimental Data and Assessment of the Need for Individual Patient Minimum Inhibitory Concentration Value
title_short What Is the Best Vancomycin Therapeutic Drug Monitoring Parameter to Assess Efficacy? A Critical Review of Experimental Data and Assessment of the Need for Individual Patient Minimum Inhibitory Concentration Value
title_sort what is the best vancomycin therapeutic drug monitoring parameter to assess efficacy a critical review of experimental data and assessment of the need for individual patient minimum inhibitory concentration value
topic vancomycin
pharmacokinetics
pharmacodynamics
therapeutic drug monitoring
url https://www.mdpi.com/2076-2607/11/3/567
work_keys_str_mv AT brucerdalton whatisthebestvancomycintherapeuticdrugmonitoringparametertoassessefficacyacriticalreviewofexperimentaldataandassessmentoftheneedforindividualpatientminimuminhibitoryconcentrationvalue