Effects of the Argus II Retinal Prosthesis System on the Quality of Life of Patients With Ultra-Low Vision Due to Retinitis Pigmentosa: Protocol for a Single-Arm, Mixed Methods Study

BackgroundRetinitis pigmentosa is an incurable, degenerative retinal condition causing progressive sight loss, significantly affecting patients’ quality of life. The Argus II Retinal Prosthesis is a surgically implanted medical device that delivers electrical stimulation to the retina. It is intende...

Full description

Bibliographic Details
Main Authors: White, Judith, Knight, Laura, da Cruz, Lyndon, Stanga, Paulo E, Patrick, Hannah, Powell, Helen, Berry, Lee, Withers, Kathleen, Carolan-Rees, Grace, Jackson, Timothy L
Format: Article
Language:English
Published: JMIR Publications 2021-01-01
Series:JMIR Research Protocols
Online Access:http://www.researchprotocols.org/2021/1/e17436/
_version_ 1818877245757849600
author White, Judith
Knight, Laura
da Cruz, Lyndon
Stanga, Paulo E
Patrick, Hannah
Powell, Helen
Berry, Lee
Withers, Kathleen
Carolan-Rees, Grace
Jackson, Timothy L
author_facet White, Judith
Knight, Laura
da Cruz, Lyndon
Stanga, Paulo E
Patrick, Hannah
Powell, Helen
Berry, Lee
Withers, Kathleen
Carolan-Rees, Grace
Jackson, Timothy L
author_sort White, Judith
collection DOAJ
description BackgroundRetinitis pigmentosa is an incurable, degenerative retinal condition causing progressive sight loss, significantly affecting patients’ quality of life. The Argus II Retinal Prosthesis is a surgically implanted medical device that delivers electrical stimulation to the retina. It is intended to produce a form of artificial vision for blind people with severe-to-profound retinitis pigmentosa by stimulating the remaining viable retinal cells to induce visual perception. This study has been initiated by National Health Service England’s Commissioning through Evaluation program and funded through the National Institute of Health Research of the United Kingdom. ObjectiveThe aim of this study was to assess the effect of the Argus II device on patient’s daily activities and quality of life. MethodsThis protocol is a prospective, single-arm, open-label, mixed methods study on 10 consecutive participants receiving the Argus II device. The patient representatives played an integral role in the design of this study. Eligibility criteria include ultra-low vision in both eyes as a result of end-stage retinitis pigmentosa and a willingness and capacity to complete the postimplantation rehabilitation program. Participants will be interviewed by independent researchers at baseline and 12 months later by using a semistructured, in-depth approach, alongside validated questionnaires (Impact of Vision Impairment-Very Low Vision, 5-level EuroQoL-5 dimensions scale, EuroQoL-visual analog scale, and Hospital Anxiety and Depression Scale) and a bespoke device-related questionnaire, which includes questions about users’ experiences with the procedure, the device, and rehabilitation. The effect of the device on patients’ functional vision and activities of daily living will be assessed by vision rehabilitation specialists using a set of tests measured on an ordinal scale (eg, ability to locate objects and avoid obstacles). Clinical outcomes include full-field stimulus light threshold, square localization, direction of motion, grating visual acuity, Landolt-C, procedural success, and adverse events. Qualitative and quantitative outcomes will be linked in a single database to enable individual participant measures to be considered in toto, comparing baseline to the final review. ResultsThis study was approved by the local ethics committee on April 24, 2019 (London-Camberwell St. Giles Research Ethics Committee, reference 19/LO/0429). It has also been approved by the Health Research Authority and Health and Care Research Wales. At the time of protocol writing, Argus II was available for use in the United Kingdom; however, the manufacturer recently withdrew the Argus II device from sale in the United Kingdom. Therefore, the study is not going ahead at this time. ConclusionsThe mixed methods approach provides a rich and in-depth assessment of the effect of the device on participants’ quality of life. Despite the work not going ahead, the publication of this publicly funded protocol is important for researchers planning similar work. International Registered Report Identifier (IRRID)PRR1-10.2196/17436
first_indexed 2024-12-19T13:55:13Z
format Article
id doaj.art-e9674b970c064db3be4b3e977199d2d7
institution Directory Open Access Journal
issn 1929-0748
language English
last_indexed 2024-12-19T13:55:13Z
publishDate 2021-01-01
publisher JMIR Publications
record_format Article
series JMIR Research Protocols
spelling doaj.art-e9674b970c064db3be4b3e977199d2d72022-12-21T20:18:37ZengJMIR PublicationsJMIR Research Protocols1929-07482021-01-01101e1743610.2196/17436Effects of the Argus II Retinal Prosthesis System on the Quality of Life of Patients With Ultra-Low Vision Due to Retinitis Pigmentosa: Protocol for a Single-Arm, Mixed Methods StudyWhite, JudithKnight, Laurada Cruz, LyndonStanga, Paulo EPatrick, HannahPowell, HelenBerry, LeeWithers, KathleenCarolan-Rees, GraceJackson, Timothy LBackgroundRetinitis pigmentosa is an incurable, degenerative retinal condition causing progressive sight loss, significantly affecting patients’ quality of life. The Argus II Retinal Prosthesis is a surgically implanted medical device that delivers electrical stimulation to the retina. It is intended to produce a form of artificial vision for blind people with severe-to-profound retinitis pigmentosa by stimulating the remaining viable retinal cells to induce visual perception. This study has been initiated by National Health Service England’s Commissioning through Evaluation program and funded through the National Institute of Health Research of the United Kingdom. ObjectiveThe aim of this study was to assess the effect of the Argus II device on patient’s daily activities and quality of life. MethodsThis protocol is a prospective, single-arm, open-label, mixed methods study on 10 consecutive participants receiving the Argus II device. The patient representatives played an integral role in the design of this study. Eligibility criteria include ultra-low vision in both eyes as a result of end-stage retinitis pigmentosa and a willingness and capacity to complete the postimplantation rehabilitation program. Participants will be interviewed by independent researchers at baseline and 12 months later by using a semistructured, in-depth approach, alongside validated questionnaires (Impact of Vision Impairment-Very Low Vision, 5-level EuroQoL-5 dimensions scale, EuroQoL-visual analog scale, and Hospital Anxiety and Depression Scale) and a bespoke device-related questionnaire, which includes questions about users’ experiences with the procedure, the device, and rehabilitation. The effect of the device on patients’ functional vision and activities of daily living will be assessed by vision rehabilitation specialists using a set of tests measured on an ordinal scale (eg, ability to locate objects and avoid obstacles). Clinical outcomes include full-field stimulus light threshold, square localization, direction of motion, grating visual acuity, Landolt-C, procedural success, and adverse events. Qualitative and quantitative outcomes will be linked in a single database to enable individual participant measures to be considered in toto, comparing baseline to the final review. ResultsThis study was approved by the local ethics committee on April 24, 2019 (London-Camberwell St. Giles Research Ethics Committee, reference 19/LO/0429). It has also been approved by the Health Research Authority and Health and Care Research Wales. At the time of protocol writing, Argus II was available for use in the United Kingdom; however, the manufacturer recently withdrew the Argus II device from sale in the United Kingdom. Therefore, the study is not going ahead at this time. ConclusionsThe mixed methods approach provides a rich and in-depth assessment of the effect of the device on participants’ quality of life. Despite the work not going ahead, the publication of this publicly funded protocol is important for researchers planning similar work. International Registered Report Identifier (IRRID)PRR1-10.2196/17436http://www.researchprotocols.org/2021/1/e17436/
spellingShingle White, Judith
Knight, Laura
da Cruz, Lyndon
Stanga, Paulo E
Patrick, Hannah
Powell, Helen
Berry, Lee
Withers, Kathleen
Carolan-Rees, Grace
Jackson, Timothy L
Effects of the Argus II Retinal Prosthesis System on the Quality of Life of Patients With Ultra-Low Vision Due to Retinitis Pigmentosa: Protocol for a Single-Arm, Mixed Methods Study
JMIR Research Protocols
title Effects of the Argus II Retinal Prosthesis System on the Quality of Life of Patients With Ultra-Low Vision Due to Retinitis Pigmentosa: Protocol for a Single-Arm, Mixed Methods Study
title_full Effects of the Argus II Retinal Prosthesis System on the Quality of Life of Patients With Ultra-Low Vision Due to Retinitis Pigmentosa: Protocol for a Single-Arm, Mixed Methods Study
title_fullStr Effects of the Argus II Retinal Prosthesis System on the Quality of Life of Patients With Ultra-Low Vision Due to Retinitis Pigmentosa: Protocol for a Single-Arm, Mixed Methods Study
title_full_unstemmed Effects of the Argus II Retinal Prosthesis System on the Quality of Life of Patients With Ultra-Low Vision Due to Retinitis Pigmentosa: Protocol for a Single-Arm, Mixed Methods Study
title_short Effects of the Argus II Retinal Prosthesis System on the Quality of Life of Patients With Ultra-Low Vision Due to Retinitis Pigmentosa: Protocol for a Single-Arm, Mixed Methods Study
title_sort effects of the argus ii retinal prosthesis system on the quality of life of patients with ultra low vision due to retinitis pigmentosa protocol for a single arm mixed methods study
url http://www.researchprotocols.org/2021/1/e17436/
work_keys_str_mv AT whitejudith effectsoftheargusiiretinalprosthesissystemonthequalityoflifeofpatientswithultralowvisionduetoretinitispigmentosaprotocolforasinglearmmixedmethodsstudy
AT knightlaura effectsoftheargusiiretinalprosthesissystemonthequalityoflifeofpatientswithultralowvisionduetoretinitispigmentosaprotocolforasinglearmmixedmethodsstudy
AT dacruzlyndon effectsoftheargusiiretinalprosthesissystemonthequalityoflifeofpatientswithultralowvisionduetoretinitispigmentosaprotocolforasinglearmmixedmethodsstudy
AT stangapauloe effectsoftheargusiiretinalprosthesissystemonthequalityoflifeofpatientswithultralowvisionduetoretinitispigmentosaprotocolforasinglearmmixedmethodsstudy
AT patrickhannah effectsoftheargusiiretinalprosthesissystemonthequalityoflifeofpatientswithultralowvisionduetoretinitispigmentosaprotocolforasinglearmmixedmethodsstudy
AT powellhelen effectsoftheargusiiretinalprosthesissystemonthequalityoflifeofpatientswithultralowvisionduetoretinitispigmentosaprotocolforasinglearmmixedmethodsstudy
AT berrylee effectsoftheargusiiretinalprosthesissystemonthequalityoflifeofpatientswithultralowvisionduetoretinitispigmentosaprotocolforasinglearmmixedmethodsstudy
AT witherskathleen effectsoftheargusiiretinalprosthesissystemonthequalityoflifeofpatientswithultralowvisionduetoretinitispigmentosaprotocolforasinglearmmixedmethodsstudy
AT carolanreesgrace effectsoftheargusiiretinalprosthesissystemonthequalityoflifeofpatientswithultralowvisionduetoretinitispigmentosaprotocolforasinglearmmixedmethodsstudy
AT jacksontimothyl effectsoftheargusiiretinalprosthesissystemonthequalityoflifeofpatientswithultralowvisionduetoretinitispigmentosaprotocolforasinglearmmixedmethodsstudy