Replacement Strategy of Insulators Established by Probability of Failure

Insulators comprise only 5% of the capital cost of transmission lines; they are accountable for 70% of line interruptions and 50% of maintenance costs of transmission lines. Major transmission lines situated in different parts of the world were mostly all constructed 30 years ago. These lines have e...

Full description

Bibliographic Details
Main Authors: Simpy Sanyal, Taeyong Kim, Chang-Sung Seok, Junsin Yi, Ja-Bin Koo, Ju-Am Son, In-Hyuk Choi
Format: Article
Language:English
Published: MDPI AG 2020-04-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/8/2043
_version_ 1797570216992964608
author Simpy Sanyal
Taeyong Kim
Chang-Sung Seok
Junsin Yi
Ja-Bin Koo
Ju-Am Son
In-Hyuk Choi
author_facet Simpy Sanyal
Taeyong Kim
Chang-Sung Seok
Junsin Yi
Ja-Bin Koo
Ju-Am Son
In-Hyuk Choi
author_sort Simpy Sanyal
collection DOAJ
description Insulators comprise only 5% of the capital cost of transmission lines; they are accountable for 70% of line interruptions and 50% of maintenance costs of transmission lines. Major transmission lines situated in different parts of the world were mostly all constructed 30 years ago. These lines have either completed or are approaching the active life at 30 years. It is not possible to replace all insulators at a time in any utility. From a standpoint of consistency, it is quite important to locate insulators that require replacement prior to the occurrence of failure. Recalling these issues, a replacement strategy was modeled on insulator samples, operated at 154 kV, mechanical and electrical rating (M+E) 25,000 lbs and within the 10–50 years (Y) age group, collected in bulk for laboratory evaluation, based on the probability of mechanical failure (P(F)) of insulators. For conducting these studies, tensile load test such as combined electrical and mechanical failing load test was performed on selected 30 new and aged porcelain insulator samples from bulk to access recent condition. It was observed that insulators under service for 50 years manifested a decrease of 89.3% in quality factor (K), as compared to insulators within 10 years of service. A micro-structural study was carried out by using an optical microscope (OM) and a scanning electron microscope (SEM) for the further confirmation of previous evaluations. P(F) was derived by implementing Weibull distribution on the experimental observations. It was observed that insulators with an age of 50 years depicted a 2.7% increase in P(F), as compared to insulators with an age of 10 years. This article discussed a strategy for accessing the recent condition of new, aged bulk samples and the criteria of the replacement of the insulator string based on P(F).
first_indexed 2024-03-10T20:21:46Z
format Article
id doaj.art-e982b82c8f6c4ad0824babb4785cffaa
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-10T20:21:46Z
publishDate 2020-04-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-e982b82c8f6c4ad0824babb4785cffaa2023-11-19T22:08:38ZengMDPI AGEnergies1996-10732020-04-01138204310.3390/en13082043Replacement Strategy of Insulators Established by Probability of FailureSimpy Sanyal0Taeyong Kim1Chang-Sung Seok2Junsin Yi3Ja-Bin Koo4Ju-Am Son5In-Hyuk Choi6College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, KoreaCollege of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, KoreaCollege of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, KoreaCollege of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, Korea2KEPCO Research Institute, Daejeon 34056, Korea2KEPCO Research Institute, Daejeon 34056, Korea2KEPCO Research Institute, Daejeon 34056, KoreaInsulators comprise only 5% of the capital cost of transmission lines; they are accountable for 70% of line interruptions and 50% of maintenance costs of transmission lines. Major transmission lines situated in different parts of the world were mostly all constructed 30 years ago. These lines have either completed or are approaching the active life at 30 years. It is not possible to replace all insulators at a time in any utility. From a standpoint of consistency, it is quite important to locate insulators that require replacement prior to the occurrence of failure. Recalling these issues, a replacement strategy was modeled on insulator samples, operated at 154 kV, mechanical and electrical rating (M+E) 25,000 lbs and within the 10–50 years (Y) age group, collected in bulk for laboratory evaluation, based on the probability of mechanical failure (P(F)) of insulators. For conducting these studies, tensile load test such as combined electrical and mechanical failing load test was performed on selected 30 new and aged porcelain insulator samples from bulk to access recent condition. It was observed that insulators under service for 50 years manifested a decrease of 89.3% in quality factor (K), as compared to insulators within 10 years of service. A micro-structural study was carried out by using an optical microscope (OM) and a scanning electron microscope (SEM) for the further confirmation of previous evaluations. P(F) was derived by implementing Weibull distribution on the experimental observations. It was observed that insulators with an age of 50 years depicted a 2.7% increase in P(F), as compared to insulators with an age of 10 years. This article discussed a strategy for accessing the recent condition of new, aged bulk samples and the criteria of the replacement of the insulator string based on P(F).https://www.mdpi.com/1996-1073/13/8/2043probability of failurereplacement strategytensile load testmicrostructural studyWeibull distribution
spellingShingle Simpy Sanyal
Taeyong Kim
Chang-Sung Seok
Junsin Yi
Ja-Bin Koo
Ju-Am Son
In-Hyuk Choi
Replacement Strategy of Insulators Established by Probability of Failure
Energies
probability of failure
replacement strategy
tensile load test
microstructural study
Weibull distribution
title Replacement Strategy of Insulators Established by Probability of Failure
title_full Replacement Strategy of Insulators Established by Probability of Failure
title_fullStr Replacement Strategy of Insulators Established by Probability of Failure
title_full_unstemmed Replacement Strategy of Insulators Established by Probability of Failure
title_short Replacement Strategy of Insulators Established by Probability of Failure
title_sort replacement strategy of insulators established by probability of failure
topic probability of failure
replacement strategy
tensile load test
microstructural study
Weibull distribution
url https://www.mdpi.com/1996-1073/13/8/2043
work_keys_str_mv AT simpysanyal replacementstrategyofinsulatorsestablishedbyprobabilityoffailure
AT taeyongkim replacementstrategyofinsulatorsestablishedbyprobabilityoffailure
AT changsungseok replacementstrategyofinsulatorsestablishedbyprobabilityoffailure
AT junsinyi replacementstrategyofinsulatorsestablishedbyprobabilityoffailure
AT jabinkoo replacementstrategyofinsulatorsestablishedbyprobabilityoffailure
AT juamson replacementstrategyofinsulatorsestablishedbyprobabilityoffailure
AT inhyukchoi replacementstrategyofinsulatorsestablishedbyprobabilityoffailure