Replacement Strategy of Insulators Established by Probability of Failure
Insulators comprise only 5% of the capital cost of transmission lines; they are accountable for 70% of line interruptions and 50% of maintenance costs of transmission lines. Major transmission lines situated in different parts of the world were mostly all constructed 30 years ago. These lines have e...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-04-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/13/8/2043 |
_version_ | 1797570216992964608 |
---|---|
author | Simpy Sanyal Taeyong Kim Chang-Sung Seok Junsin Yi Ja-Bin Koo Ju-Am Son In-Hyuk Choi |
author_facet | Simpy Sanyal Taeyong Kim Chang-Sung Seok Junsin Yi Ja-Bin Koo Ju-Am Son In-Hyuk Choi |
author_sort | Simpy Sanyal |
collection | DOAJ |
description | Insulators comprise only 5% of the capital cost of transmission lines; they are accountable for 70% of line interruptions and 50% of maintenance costs of transmission lines. Major transmission lines situated in different parts of the world were mostly all constructed 30 years ago. These lines have either completed or are approaching the active life at 30 years. It is not possible to replace all insulators at a time in any utility. From a standpoint of consistency, it is quite important to locate insulators that require replacement prior to the occurrence of failure. Recalling these issues, a replacement strategy was modeled on insulator samples, operated at 154 kV, mechanical and electrical rating (M+E) 25,000 lbs and within the 10–50 years (Y) age group, collected in bulk for laboratory evaluation, based on the probability of mechanical failure (P(F)) of insulators. For conducting these studies, tensile load test such as combined electrical and mechanical failing load test was performed on selected 30 new and aged porcelain insulator samples from bulk to access recent condition. It was observed that insulators under service for 50 years manifested a decrease of 89.3% in quality factor (K), as compared to insulators within 10 years of service. A micro-structural study was carried out by using an optical microscope (OM) and a scanning electron microscope (SEM) for the further confirmation of previous evaluations. P(F) was derived by implementing Weibull distribution on the experimental observations. It was observed that insulators with an age of 50 years depicted a 2.7% increase in P(F), as compared to insulators with an age of 10 years. This article discussed a strategy for accessing the recent condition of new, aged bulk samples and the criteria of the replacement of the insulator string based on P(F). |
first_indexed | 2024-03-10T20:21:46Z |
format | Article |
id | doaj.art-e982b82c8f6c4ad0824babb4785cffaa |
institution | Directory Open Access Journal |
issn | 1996-1073 |
language | English |
last_indexed | 2024-03-10T20:21:46Z |
publishDate | 2020-04-01 |
publisher | MDPI AG |
record_format | Article |
series | Energies |
spelling | doaj.art-e982b82c8f6c4ad0824babb4785cffaa2023-11-19T22:08:38ZengMDPI AGEnergies1996-10732020-04-01138204310.3390/en13082043Replacement Strategy of Insulators Established by Probability of FailureSimpy Sanyal0Taeyong Kim1Chang-Sung Seok2Junsin Yi3Ja-Bin Koo4Ju-Am Son5In-Hyuk Choi6College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, KoreaCollege of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, KoreaCollege of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, KoreaCollege of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, Korea2KEPCO Research Institute, Daejeon 34056, Korea2KEPCO Research Institute, Daejeon 34056, Korea2KEPCO Research Institute, Daejeon 34056, KoreaInsulators comprise only 5% of the capital cost of transmission lines; they are accountable for 70% of line interruptions and 50% of maintenance costs of transmission lines. Major transmission lines situated in different parts of the world were mostly all constructed 30 years ago. These lines have either completed or are approaching the active life at 30 years. It is not possible to replace all insulators at a time in any utility. From a standpoint of consistency, it is quite important to locate insulators that require replacement prior to the occurrence of failure. Recalling these issues, a replacement strategy was modeled on insulator samples, operated at 154 kV, mechanical and electrical rating (M+E) 25,000 lbs and within the 10–50 years (Y) age group, collected in bulk for laboratory evaluation, based on the probability of mechanical failure (P(F)) of insulators. For conducting these studies, tensile load test such as combined electrical and mechanical failing load test was performed on selected 30 new and aged porcelain insulator samples from bulk to access recent condition. It was observed that insulators under service for 50 years manifested a decrease of 89.3% in quality factor (K), as compared to insulators within 10 years of service. A micro-structural study was carried out by using an optical microscope (OM) and a scanning electron microscope (SEM) for the further confirmation of previous evaluations. P(F) was derived by implementing Weibull distribution on the experimental observations. It was observed that insulators with an age of 50 years depicted a 2.7% increase in P(F), as compared to insulators with an age of 10 years. This article discussed a strategy for accessing the recent condition of new, aged bulk samples and the criteria of the replacement of the insulator string based on P(F).https://www.mdpi.com/1996-1073/13/8/2043probability of failurereplacement strategytensile load testmicrostructural studyWeibull distribution |
spellingShingle | Simpy Sanyal Taeyong Kim Chang-Sung Seok Junsin Yi Ja-Bin Koo Ju-Am Son In-Hyuk Choi Replacement Strategy of Insulators Established by Probability of Failure Energies probability of failure replacement strategy tensile load test microstructural study Weibull distribution |
title | Replacement Strategy of Insulators Established by Probability of Failure |
title_full | Replacement Strategy of Insulators Established by Probability of Failure |
title_fullStr | Replacement Strategy of Insulators Established by Probability of Failure |
title_full_unstemmed | Replacement Strategy of Insulators Established by Probability of Failure |
title_short | Replacement Strategy of Insulators Established by Probability of Failure |
title_sort | replacement strategy of insulators established by probability of failure |
topic | probability of failure replacement strategy tensile load test microstructural study Weibull distribution |
url | https://www.mdpi.com/1996-1073/13/8/2043 |
work_keys_str_mv | AT simpysanyal replacementstrategyofinsulatorsestablishedbyprobabilityoffailure AT taeyongkim replacementstrategyofinsulatorsestablishedbyprobabilityoffailure AT changsungseok replacementstrategyofinsulatorsestablishedbyprobabilityoffailure AT junsinyi replacementstrategyofinsulatorsestablishedbyprobabilityoffailure AT jabinkoo replacementstrategyofinsulatorsestablishedbyprobabilityoffailure AT juamson replacementstrategyofinsulatorsestablishedbyprobabilityoffailure AT inhyukchoi replacementstrategyofinsulatorsestablishedbyprobabilityoffailure |