Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation
Power systems that are highly loaded, especially by a stochastic supply of renewables and the presence of storages, require dynamic measurements for their optimal control. Phasor measurement units (PMUs) can be used to capture electrical parameters of a power system. Standards on the PMU dynamic per...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Polish Academy of Sciences
2018-09-01
|
Series: | Archives of Electrical Engineering |
Subjects: | |
Online Access: | https://journals.pan.pl/Content/107872/PDF/AEE-67-3-2018-10.09_art_5.pdf |
_version_ | 1818172458459463680 |
---|---|
author | Bartłomiej Arendarski Steffen Rabe Wolfram Heineken Przemysław Komarnicki |
author_facet | Bartłomiej Arendarski Steffen Rabe Wolfram Heineken Przemysław Komarnicki |
author_sort | Bartłomiej Arendarski |
collection | DOAJ |
description | Power systems that are highly loaded, especially by a stochastic supply of renewables and the presence of storages, require dynamic measurements for their optimal control. Phasor measurement units (PMUs) can be used to capture electrical parameters of a power system. Standards on the PMU dynamic performance have been modified to incorporate their new dynamic mode of operation. This paper examines the PMU dynamic performance and proposes essential algorithms for measurement accuracy verification. Measurements of dynamic input signals, which vary in amplitude or frequency, were taken during automated tests of two PMUs. The test results are presented and expounded with further recommendation for the performance requirements. This paper also presents and examines applied testing procedures with relevance to the specifications of the IEEE Standard for Synchrophasor C37.118.1™-2011 and its amendment C37.118.1a™-2014. |
first_indexed | 2024-12-11T19:12:56Z |
format | Article |
id | doaj.art-e9b7e017203f4ce2a3a75124ae671e18 |
institution | Directory Open Access Journal |
issn | 2300-2506 |
language | English |
last_indexed | 2024-12-11T19:12:56Z |
publishDate | 2018-09-01 |
publisher | Polish Academy of Sciences |
record_format | Article |
series | Archives of Electrical Engineering |
spelling | doaj.art-e9b7e017203f4ce2a3a75124ae671e182022-12-22T00:53:43ZengPolish Academy of SciencesArchives of Electrical Engineering2300-25062018-09-01vol. 67No 3https://doi.org/10.24425/123661Measurement accuracy verification of phasor measurement unit with dynamic phasor estimationBartłomiej ArendarskiSteffen RabeWolfram HeinekenPrzemysław KomarnickiPower systems that are highly loaded, especially by a stochastic supply of renewables and the presence of storages, require dynamic measurements for their optimal control. Phasor measurement units (PMUs) can be used to capture electrical parameters of a power system. Standards on the PMU dynamic performance have been modified to incorporate their new dynamic mode of operation. This paper examines the PMU dynamic performance and proposes essential algorithms for measurement accuracy verification. Measurements of dynamic input signals, which vary in amplitude or frequency, were taken during automated tests of two PMUs. The test results are presented and expounded with further recommendation for the performance requirements. This paper also presents and examines applied testing procedures with relevance to the specifications of the IEEE Standard for Synchrophasor C37.118.1™-2011 and its amendment C37.118.1a™-2014.https://journals.pan.pl/Content/107872/PDF/AEE-67-3-2018-10.09_art_5.pdfdiscrete fourier transform (dft)dynamic phasormeasurement accuracyphasor measurement unit (pmu)power system |
spellingShingle | Bartłomiej Arendarski Steffen Rabe Wolfram Heineken Przemysław Komarnicki Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation Archives of Electrical Engineering discrete fourier transform (dft) dynamic phasor measurement accuracy phasor measurement unit (pmu) power system |
title | Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation |
title_full | Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation |
title_fullStr | Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation |
title_full_unstemmed | Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation |
title_short | Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation |
title_sort | measurement accuracy verification of phasor measurement unit with dynamic phasor estimation |
topic | discrete fourier transform (dft) dynamic phasor measurement accuracy phasor measurement unit (pmu) power system |
url | https://journals.pan.pl/Content/107872/PDF/AEE-67-3-2018-10.09_art_5.pdf |
work_keys_str_mv | AT bartłomiejarendarski measurementaccuracyverificationofphasormeasurementunitwithdynamicphasorestimation AT steffenrabe measurementaccuracyverificationofphasormeasurementunitwithdynamicphasorestimation AT wolframheineken measurementaccuracyverificationofphasormeasurementunitwithdynamicphasorestimation AT przemysławkomarnicki measurementaccuracyverificationofphasormeasurementunitwithdynamicphasorestimation |