Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation

Power systems that are highly loaded, especially by a stochastic supply of renewables and the presence of storages, require dynamic measurements for their optimal control. Phasor measurement units (PMUs) can be used to capture electrical parameters of a power system. Standards on the PMU dynamic per...

Full description

Bibliographic Details
Main Authors: Bartłomiej Arendarski, Steffen Rabe, Wolfram Heineken, Przemysław Komarnicki
Format: Article
Language:English
Published: Polish Academy of Sciences 2018-09-01
Series:Archives of Electrical Engineering
Subjects:
Online Access:https://journals.pan.pl/Content/107872/PDF/AEE-67-3-2018-10.09_art_5.pdf
_version_ 1818172458459463680
author Bartłomiej Arendarski
Steffen Rabe
Wolfram Heineken
Przemysław Komarnicki
author_facet Bartłomiej Arendarski
Steffen Rabe
Wolfram Heineken
Przemysław Komarnicki
author_sort Bartłomiej Arendarski
collection DOAJ
description Power systems that are highly loaded, especially by a stochastic supply of renewables and the presence of storages, require dynamic measurements for their optimal control. Phasor measurement units (PMUs) can be used to capture electrical parameters of a power system. Standards on the PMU dynamic performance have been modified to incorporate their new dynamic mode of operation. This paper examines the PMU dynamic performance and proposes essential algorithms for measurement accuracy verification. Measurements of dynamic input signals, which vary in amplitude or frequency, were taken during automated tests of two PMUs. The test results are presented and expounded with further recommendation for the performance requirements. This paper also presents and examines applied testing procedures with relevance to the specifications of the IEEE Standard for Synchrophasor C37.118.1™-2011 and its amendment C37.118.1a™-2014.
first_indexed 2024-12-11T19:12:56Z
format Article
id doaj.art-e9b7e017203f4ce2a3a75124ae671e18
institution Directory Open Access Journal
issn 2300-2506
language English
last_indexed 2024-12-11T19:12:56Z
publishDate 2018-09-01
publisher Polish Academy of Sciences
record_format Article
series Archives of Electrical Engineering
spelling doaj.art-e9b7e017203f4ce2a3a75124ae671e182022-12-22T00:53:43ZengPolish Academy of SciencesArchives of Electrical Engineering2300-25062018-09-01vol. 67No 3https://doi.org/10.24425/123661Measurement accuracy verification of phasor measurement unit with dynamic phasor estimationBartłomiej ArendarskiSteffen RabeWolfram HeinekenPrzemysław KomarnickiPower systems that are highly loaded, especially by a stochastic supply of renewables and the presence of storages, require dynamic measurements for their optimal control. Phasor measurement units (PMUs) can be used to capture electrical parameters of a power system. Standards on the PMU dynamic performance have been modified to incorporate their new dynamic mode of operation. This paper examines the PMU dynamic performance and proposes essential algorithms for measurement accuracy verification. Measurements of dynamic input signals, which vary in amplitude or frequency, were taken during automated tests of two PMUs. The test results are presented and expounded with further recommendation for the performance requirements. This paper also presents and examines applied testing procedures with relevance to the specifications of the IEEE Standard for Synchrophasor C37.118.1™-2011 and its amendment C37.118.1a™-2014.https://journals.pan.pl/Content/107872/PDF/AEE-67-3-2018-10.09_art_5.pdfdiscrete fourier transform (dft)dynamic phasormeasurement accuracyphasor measurement unit (pmu)power system
spellingShingle Bartłomiej Arendarski
Steffen Rabe
Wolfram Heineken
Przemysław Komarnicki
Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation
Archives of Electrical Engineering
discrete fourier transform (dft)
dynamic phasor
measurement accuracy
phasor measurement unit (pmu)
power system
title Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation
title_full Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation
title_fullStr Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation
title_full_unstemmed Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation
title_short Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation
title_sort measurement accuracy verification of phasor measurement unit with dynamic phasor estimation
topic discrete fourier transform (dft)
dynamic phasor
measurement accuracy
phasor measurement unit (pmu)
power system
url https://journals.pan.pl/Content/107872/PDF/AEE-67-3-2018-10.09_art_5.pdf
work_keys_str_mv AT bartłomiejarendarski measurementaccuracyverificationofphasormeasurementunitwithdynamicphasorestimation
AT steffenrabe measurementaccuracyverificationofphasormeasurementunitwithdynamicphasorestimation
AT wolframheineken measurementaccuracyverificationofphasormeasurementunitwithdynamicphasorestimation
AT przemysławkomarnicki measurementaccuracyverificationofphasormeasurementunitwithdynamicphasorestimation