Pulse Shape Analysis and Discrimination for Silicon-Photomultipliers in Helium-4 Gas Scintillation Neutron Detector

Using natural helium (helium-4), the Arktis 180-bar pressurized gas scintillator is capable of detecting and distinguishing fast neutrons and gammas. The detector has a unique design of three optically separated segments in which 12 silicon-photomultiplier (SiPM) pairs are positioned equilaterally a...

Full description

Bibliographic Details
Main Authors: Barker Cathleen, Zhu Ting, Rolison Lucas, Kiff Scott, Jordan Kelly, Enqvist Andreas
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:EPJ Web of Conferences
Subjects:
Online Access:https://doi.org/10.1051/epjconf/201817007002
_version_ 1819096311054467072
author Barker Cathleen
Zhu Ting
Rolison Lucas
Kiff Scott
Jordan Kelly
Enqvist Andreas
author_facet Barker Cathleen
Zhu Ting
Rolison Lucas
Kiff Scott
Jordan Kelly
Enqvist Andreas
author_sort Barker Cathleen
collection DOAJ
description Using natural helium (helium-4), the Arktis 180-bar pressurized gas scintillator is capable of detecting and distinguishing fast neutrons and gammas. The detector has a unique design of three optically separated segments in which 12 silicon-photomultiplier (SiPM) pairs are positioned equilaterally across the detector to allow for them to be fully immersed in the helium-4 gas volume; consequently, no additional optical interfaces are necessary. The SiPM signals were amplified, shaped, and readout by an analog board; a 250 MHz, 14-bit digitizer was used to examine the output pulses from each SiPMpair channel. The SiPM over-voltage had to be adjusted in order to reduce pulse clipping and negative overshoot, which was observed for events with high scintillation production. Pulse shaped discrimination (PSD) was conducted by evaluating three different parameters: time over threshold (TOT), pulse amplitude, and pulse integral. In order to differentiate high and low energy events, a 30ns gate window was implemented to group pulses from two SiPM channels or more for the calculation of TOT. It was demonstrated that pulses from a single SiPM channel within the 30ns window corresponded to low-energy gamma events while groups of pulses from two-channels or more were most likely neutron events. Due to gamma pulses having lower pulse amplitude, the percentage of measured gamma also depends on the threshold value in TOT calculations. Similarly, the threshold values were varied for the optimal PSD methods of using pulse amplitude and pulse area parameters. Helium-4 detectors equipped with SiPMs are excellent for in-the-field radiation measurement of nuclear spent fuel casks. With optimized PSD methods, the goal of developing a fuel cask content monitoring and inspection system based on these helium-4 detectors will be achieved.
first_indexed 2024-12-21T23:57:10Z
format Article
id doaj.art-ea258e69dd2046f88e8d0dfaf5085afa
institution Directory Open Access Journal
issn 2100-014X
language English
last_indexed 2024-12-21T23:57:10Z
publishDate 2018-01-01
publisher EDP Sciences
record_format Article
series EPJ Web of Conferences
spelling doaj.art-ea258e69dd2046f88e8d0dfaf5085afa2022-12-21T18:45:48ZengEDP SciencesEPJ Web of Conferences2100-014X2018-01-011700700210.1051/epjconf/201817007002epjconf_animma2018_07002Pulse Shape Analysis and Discrimination for Silicon-Photomultipliers in Helium-4 Gas Scintillation Neutron DetectorBarker CathleenZhu TingRolison LucasKiff ScottJordan KellyEnqvist AndreasUsing natural helium (helium-4), the Arktis 180-bar pressurized gas scintillator is capable of detecting and distinguishing fast neutrons and gammas. The detector has a unique design of three optically separated segments in which 12 silicon-photomultiplier (SiPM) pairs are positioned equilaterally across the detector to allow for them to be fully immersed in the helium-4 gas volume; consequently, no additional optical interfaces are necessary. The SiPM signals were amplified, shaped, and readout by an analog board; a 250 MHz, 14-bit digitizer was used to examine the output pulses from each SiPMpair channel. The SiPM over-voltage had to be adjusted in order to reduce pulse clipping and negative overshoot, which was observed for events with high scintillation production. Pulse shaped discrimination (PSD) was conducted by evaluating three different parameters: time over threshold (TOT), pulse amplitude, and pulse integral. In order to differentiate high and low energy events, a 30ns gate window was implemented to group pulses from two SiPM channels or more for the calculation of TOT. It was demonstrated that pulses from a single SiPM channel within the 30ns window corresponded to low-energy gamma events while groups of pulses from two-channels or more were most likely neutron events. Due to gamma pulses having lower pulse amplitude, the percentage of measured gamma also depends on the threshold value in TOT calculations. Similarly, the threshold values were varied for the optimal PSD methods of using pulse amplitude and pulse area parameters. Helium-4 detectors equipped with SiPMs are excellent for in-the-field radiation measurement of nuclear spent fuel casks. With optimized PSD methods, the goal of developing a fuel cask content monitoring and inspection system based on these helium-4 detectors will be achieved.https://doi.org/10.1051/epjconf/201817007002SiPMhelium-4 detectorpulse shaped discriminationdigitizer
spellingShingle Barker Cathleen
Zhu Ting
Rolison Lucas
Kiff Scott
Jordan Kelly
Enqvist Andreas
Pulse Shape Analysis and Discrimination for Silicon-Photomultipliers in Helium-4 Gas Scintillation Neutron Detector
EPJ Web of Conferences
SiPM
helium-4 detector
pulse shaped discrimination
digitizer
title Pulse Shape Analysis and Discrimination for Silicon-Photomultipliers in Helium-4 Gas Scintillation Neutron Detector
title_full Pulse Shape Analysis and Discrimination for Silicon-Photomultipliers in Helium-4 Gas Scintillation Neutron Detector
title_fullStr Pulse Shape Analysis and Discrimination for Silicon-Photomultipliers in Helium-4 Gas Scintillation Neutron Detector
title_full_unstemmed Pulse Shape Analysis and Discrimination for Silicon-Photomultipliers in Helium-4 Gas Scintillation Neutron Detector
title_short Pulse Shape Analysis and Discrimination for Silicon-Photomultipliers in Helium-4 Gas Scintillation Neutron Detector
title_sort pulse shape analysis and discrimination for silicon photomultipliers in helium 4 gas scintillation neutron detector
topic SiPM
helium-4 detector
pulse shaped discrimination
digitizer
url https://doi.org/10.1051/epjconf/201817007002
work_keys_str_mv AT barkercathleen pulseshapeanalysisanddiscriminationforsiliconphotomultipliersinhelium4gasscintillationneutrondetector
AT zhuting pulseshapeanalysisanddiscriminationforsiliconphotomultipliersinhelium4gasscintillationneutrondetector
AT rolisonlucas pulseshapeanalysisanddiscriminationforsiliconphotomultipliersinhelium4gasscintillationneutrondetector
AT kiffscott pulseshapeanalysisanddiscriminationforsiliconphotomultipliersinhelium4gasscintillationneutrondetector
AT jordankelly pulseshapeanalysisanddiscriminationforsiliconphotomultipliersinhelium4gasscintillationneutrondetector
AT enqvistandreas pulseshapeanalysisanddiscriminationforsiliconphotomultipliersinhelium4gasscintillationneutrondetector