Functional and Metrological Issues in Arterial Simulators for Biomedical Testing Applications: A Review
Arterial simulators are a useful tool to simulate the cardiovascular system in many different fields of application and to carry out in vitro tests that would constitute a danger when performed in in vivo conditions. In the literature, a thriving series of in vitro experimental set-up examples can b...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-08-01
|
Series: | Metrology |
Subjects: | |
Online Access: | https://www.mdpi.com/2673-8244/2/3/22 |
_version_ | 1797464524819791872 |
---|---|
author | Fabio Fuiano Andrea Scorza Salvatore Andrea Sciuto |
author_facet | Fabio Fuiano Andrea Scorza Salvatore Andrea Sciuto |
author_sort | Fabio Fuiano |
collection | DOAJ |
description | Arterial simulators are a useful tool to simulate the cardiovascular system in many different fields of application and to carry out in vitro tests that would constitute a danger when performed in in vivo conditions. In the literature, a thriving series of in vitro experimental set-up examples can be found. Nevertheless, in the current scientific panorama on this topic, it seems that organic research from a metrological and functional perspective is still lacking. In this regard, the present review study aims to make a contribution by analyzing and classifying the main concerns for the cardiovascular simulators proposed in the literature from a metrological and functional point of view, according to their field of application, as well as for the transducers in the arterial experimental set-ups, measuring the main hemodynamic quantities in order to study their trends in specific testing conditions and to estimate some parameters or indicators of interest for the scientific community. |
first_indexed | 2024-03-09T18:09:24Z |
format | Article |
id | doaj.art-ea74cb49fc844306a453abca016e476c |
institution | Directory Open Access Journal |
issn | 2673-8244 |
language | English |
last_indexed | 2024-03-09T18:09:24Z |
publishDate | 2022-08-01 |
publisher | MDPI AG |
record_format | Article |
series | Metrology |
spelling | doaj.art-ea74cb49fc844306a453abca016e476c2023-11-24T09:15:16ZengMDPI AGMetrology2673-82442022-08-012336038610.3390/metrology2030022Functional and Metrological Issues in Arterial Simulators for Biomedical Testing Applications: A ReviewFabio Fuiano0Andrea Scorza1Salvatore Andrea Sciuto2Department of Industrial, Electronic and Mechanical Engineering, Roma Tre University, Via Vito Volterra 62, 00146 Rome, ItalyDepartment of Industrial, Electronic and Mechanical Engineering, Roma Tre University, Via Vito Volterra 62, 00146 Rome, ItalyDepartment of Industrial, Electronic and Mechanical Engineering, Roma Tre University, Via Vito Volterra 62, 00146 Rome, ItalyArterial simulators are a useful tool to simulate the cardiovascular system in many different fields of application and to carry out in vitro tests that would constitute a danger when performed in in vivo conditions. In the literature, a thriving series of in vitro experimental set-up examples can be found. Nevertheless, in the current scientific panorama on this topic, it seems that organic research from a metrological and functional perspective is still lacking. In this regard, the present review study aims to make a contribution by analyzing and classifying the main concerns for the cardiovascular simulators proposed in the literature from a metrological and functional point of view, according to their field of application, as well as for the transducers in the arterial experimental set-ups, measuring the main hemodynamic quantities in order to study their trends in specific testing conditions and to estimate some parameters or indicators of interest for the scientific community.https://www.mdpi.com/2673-8244/2/3/22pressureflowvelocityexperimental set-upcardiovascular simulatortransducer |
spellingShingle | Fabio Fuiano Andrea Scorza Salvatore Andrea Sciuto Functional and Metrological Issues in Arterial Simulators for Biomedical Testing Applications: A Review Metrology pressure flow velocity experimental set-up cardiovascular simulator transducer |
title | Functional and Metrological Issues in Arterial Simulators for Biomedical Testing Applications: A Review |
title_full | Functional and Metrological Issues in Arterial Simulators for Biomedical Testing Applications: A Review |
title_fullStr | Functional and Metrological Issues in Arterial Simulators for Biomedical Testing Applications: A Review |
title_full_unstemmed | Functional and Metrological Issues in Arterial Simulators for Biomedical Testing Applications: A Review |
title_short | Functional and Metrological Issues in Arterial Simulators for Biomedical Testing Applications: A Review |
title_sort | functional and metrological issues in arterial simulators for biomedical testing applications a review |
topic | pressure flow velocity experimental set-up cardiovascular simulator transducer |
url | https://www.mdpi.com/2673-8244/2/3/22 |
work_keys_str_mv | AT fabiofuiano functionalandmetrologicalissuesinarterialsimulatorsforbiomedicaltestingapplicationsareview AT andreascorza functionalandmetrologicalissuesinarterialsimulatorsforbiomedicaltestingapplicationsareview AT salvatoreandreasciuto functionalandmetrologicalissuesinarterialsimulatorsforbiomedicaltestingapplicationsareview |