Assessment of entrance skin doses and radiation protection for pediatric X-ray examination

Background and objective: Entrance skin dose is the value of the radiation absorbed dose by the skin where the X-ray beam enters the patients. Assessment of entrance skin doses, specifically for pediatric radiology, is very crucial as the children are dividing cells rapidly and are more sensitive to...

Full description

Bibliographic Details
Main Authors: Rozhan Ahmad Hamad Saeed, Runak Tahir Ali
Format: Article
Language:English
Published: Hawler Medical University 2017-12-01
Series:Zanco Journal of Medical Sciences
Subjects:
Online Access:http://zjms-hmu.org/files/articles/281217015654.pdf
_version_ 1819064454586826752
author Rozhan Ahmad Hamad Saeed
Runak Tahir Ali
author_facet Rozhan Ahmad Hamad Saeed
Runak Tahir Ali
author_sort Rozhan Ahmad Hamad Saeed
collection DOAJ
description Background and objective: Entrance skin dose is the value of the radiation absorbed dose by the skin where the X-ray beam enters the patients. Assessment of entrance skin doses, specifically for pediatric radiology, is very crucial as the children are dividing cells rapidly and are more sensitive to radiation than adults. Their cells can be easily damaged by excessive radiation dose. This study is considered as an attempt to evaluate the effects of diagnostic X-ray on pediatric patients throughout measuring the entrance skin doses and hematological parameters for pediatric patients. Ways of protecting themselves from X-ray hazards is also included. Methods: A case-control study was used to collecting the data for 70 pediatric patients from October 2015 to August 2016 at Radiology Departments of five governmental hospitals throughout Hawler city the capital of Kurdistan Region- Iraq. Pediatric patients aged between (1 day - 6 years) they were divided into case and control group by which 40 of them had got diagnostic X-ray examination as (case group) and 30 of them had not had past history of taking X-rays as (control group). Entrance skin dose was measured indirectly via parameters such as a focus on skin distance, tube voltage (KV) and tube current (mAs) in an arithmetical equation. Results: High level of entrance skin doses were received by pediatric patients in this study. Also, it was found that diagnostic X-ray has effects on pediatrics white blood cells and platelets with the significant difference between case and control group and p-values (< 0.001 and 0.006) respectively. Conclusion: Entrance skin doses levels received by pediatric patients in this study was higher than other studies level and then pediatric patients will be at risk if they are exposed to unnecessary exposure to ionizing radiation. It is important to focus on improving pediatric radiography for reducing the hazards of X-ray radiation on pediatric patients.
first_indexed 2024-12-21T15:30:50Z
format Article
id doaj.art-ea8a1006d5d64f97b29479526e41a8b7
institution Directory Open Access Journal
issn 1995-5588
1995-5596
language English
last_indexed 2024-12-21T15:30:50Z
publishDate 2017-12-01
publisher Hawler Medical University
record_format Article
series Zanco Journal of Medical Sciences
spelling doaj.art-ea8a1006d5d64f97b29479526e41a8b72022-12-21T18:58:46ZengHawler Medical UniversityZanco Journal of Medical Sciences1995-55881995-55962017-12-012131878188310.15218/zjms.2017.046Assessment of entrance skin doses and radiation protection for pediatric X-ray examinationRozhan Ahmad Hamad Saeed0Runak Tahir Ali1Erbil Directorate of HealthHawler Medical UniversityBackground and objective: Entrance skin dose is the value of the radiation absorbed dose by the skin where the X-ray beam enters the patients. Assessment of entrance skin doses, specifically for pediatric radiology, is very crucial as the children are dividing cells rapidly and are more sensitive to radiation than adults. Their cells can be easily damaged by excessive radiation dose. This study is considered as an attempt to evaluate the effects of diagnostic X-ray on pediatric patients throughout measuring the entrance skin doses and hematological parameters for pediatric patients. Ways of protecting themselves from X-ray hazards is also included. Methods: A case-control study was used to collecting the data for 70 pediatric patients from October 2015 to August 2016 at Radiology Departments of five governmental hospitals throughout Hawler city the capital of Kurdistan Region- Iraq. Pediatric patients aged between (1 day - 6 years) they were divided into case and control group by which 40 of them had got diagnostic X-ray examination as (case group) and 30 of them had not had past history of taking X-rays as (control group). Entrance skin dose was measured indirectly via parameters such as a focus on skin distance, tube voltage (KV) and tube current (mAs) in an arithmetical equation. Results: High level of entrance skin doses were received by pediatric patients in this study. Also, it was found that diagnostic X-ray has effects on pediatrics white blood cells and platelets with the significant difference between case and control group and p-values (< 0.001 and 0.006) respectively. Conclusion: Entrance skin doses levels received by pediatric patients in this study was higher than other studies level and then pediatric patients will be at risk if they are exposed to unnecessary exposure to ionizing radiation. It is important to focus on improving pediatric radiography for reducing the hazards of X-ray radiation on pediatric patients.http://zjms-hmu.org/files/articles/281217015654.pdfEntrance skin dosepediatric radiologyDiagnostic X-rayRadiation protection
spellingShingle Rozhan Ahmad Hamad Saeed
Runak Tahir Ali
Assessment of entrance skin doses and radiation protection for pediatric X-ray examination
Zanco Journal of Medical Sciences
Entrance skin dose
pediatric radiology
Diagnostic X-ray
Radiation protection
title Assessment of entrance skin doses and radiation protection for pediatric X-ray examination
title_full Assessment of entrance skin doses and radiation protection for pediatric X-ray examination
title_fullStr Assessment of entrance skin doses and radiation protection for pediatric X-ray examination
title_full_unstemmed Assessment of entrance skin doses and radiation protection for pediatric X-ray examination
title_short Assessment of entrance skin doses and radiation protection for pediatric X-ray examination
title_sort assessment of entrance skin doses and radiation protection for pediatric x ray examination
topic Entrance skin dose
pediatric radiology
Diagnostic X-ray
Radiation protection
url http://zjms-hmu.org/files/articles/281217015654.pdf
work_keys_str_mv AT rozhanahmadhamadsaeed assessmentofentranceskindosesandradiationprotectionforpediatricxrayexamination
AT runaktahirali assessmentofentranceskindosesandradiationprotectionforpediatricxrayexamination