Assessment of entrance skin doses and radiation protection for pediatric X-ray examination
Background and objective: Entrance skin dose is the value of the radiation absorbed dose by the skin where the X-ray beam enters the patients. Assessment of entrance skin doses, specifically for pediatric radiology, is very crucial as the children are dividing cells rapidly and are more sensitive to...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hawler Medical University
2017-12-01
|
Series: | Zanco Journal of Medical Sciences |
Subjects: | |
Online Access: | http://zjms-hmu.org/files/articles/281217015654.pdf |
_version_ | 1819064454586826752 |
---|---|
author | Rozhan Ahmad Hamad Saeed Runak Tahir Ali |
author_facet | Rozhan Ahmad Hamad Saeed Runak Tahir Ali |
author_sort | Rozhan Ahmad Hamad Saeed |
collection | DOAJ |
description | Background and objective: Entrance skin dose is the value of the radiation absorbed dose by the skin where the X-ray beam enters the patients. Assessment of entrance skin doses, specifically for pediatric radiology, is very crucial as the children are dividing cells rapidly and are more sensitive to radiation than adults. Their cells can be easily damaged by excessive radiation dose. This study is considered as an attempt to evaluate the effects of diagnostic X-ray on pediatric patients throughout measuring the entrance skin doses and hematological parameters for pediatric patients. Ways of protecting themselves from X-ray hazards is also included.
Methods: A case-control study was used to collecting the data for 70 pediatric patients from October 2015 to August 2016 at Radiology Departments of five governmental hospitals throughout Hawler city the capital of Kurdistan Region- Iraq. Pediatric patients aged between (1 day - 6 years) they were divided into case and control group by which 40 of them had got diagnostic X-ray examination as (case group) and 30 of them had not had past history of taking X-rays as (control group). Entrance skin dose was measured indirectly via parameters such as a focus on skin distance, tube voltage (KV) and tube current (mAs) in an arithmetical equation.
Results: High level of entrance skin doses were received by pediatric patients in this study. Also, it was found that diagnostic X-ray has effects on pediatrics white blood cells and platelets with the significant difference between case and control group and p-values (< 0.001 and 0.006) respectively.
Conclusion: Entrance skin doses levels received by pediatric patients in this study was higher than other studies level and then pediatric patients will be at risk if they are exposed to unnecessary exposure to ionizing radiation. It is important to focus on improving pediatric radiography for reducing the hazards of X-ray radiation on pediatric patients. |
first_indexed | 2024-12-21T15:30:50Z |
format | Article |
id | doaj.art-ea8a1006d5d64f97b29479526e41a8b7 |
institution | Directory Open Access Journal |
issn | 1995-5588 1995-5596 |
language | English |
last_indexed | 2024-12-21T15:30:50Z |
publishDate | 2017-12-01 |
publisher | Hawler Medical University |
record_format | Article |
series | Zanco Journal of Medical Sciences |
spelling | doaj.art-ea8a1006d5d64f97b29479526e41a8b72022-12-21T18:58:46ZengHawler Medical UniversityZanco Journal of Medical Sciences1995-55881995-55962017-12-012131878188310.15218/zjms.2017.046Assessment of entrance skin doses and radiation protection for pediatric X-ray examinationRozhan Ahmad Hamad Saeed0Runak Tahir Ali1Erbil Directorate of HealthHawler Medical UniversityBackground and objective: Entrance skin dose is the value of the radiation absorbed dose by the skin where the X-ray beam enters the patients. Assessment of entrance skin doses, specifically for pediatric radiology, is very crucial as the children are dividing cells rapidly and are more sensitive to radiation than adults. Their cells can be easily damaged by excessive radiation dose. This study is considered as an attempt to evaluate the effects of diagnostic X-ray on pediatric patients throughout measuring the entrance skin doses and hematological parameters for pediatric patients. Ways of protecting themselves from X-ray hazards is also included. Methods: A case-control study was used to collecting the data for 70 pediatric patients from October 2015 to August 2016 at Radiology Departments of five governmental hospitals throughout Hawler city the capital of Kurdistan Region- Iraq. Pediatric patients aged between (1 day - 6 years) they were divided into case and control group by which 40 of them had got diagnostic X-ray examination as (case group) and 30 of them had not had past history of taking X-rays as (control group). Entrance skin dose was measured indirectly via parameters such as a focus on skin distance, tube voltage (KV) and tube current (mAs) in an arithmetical equation. Results: High level of entrance skin doses were received by pediatric patients in this study. Also, it was found that diagnostic X-ray has effects on pediatrics white blood cells and platelets with the significant difference between case and control group and p-values (< 0.001 and 0.006) respectively. Conclusion: Entrance skin doses levels received by pediatric patients in this study was higher than other studies level and then pediatric patients will be at risk if they are exposed to unnecessary exposure to ionizing radiation. It is important to focus on improving pediatric radiography for reducing the hazards of X-ray radiation on pediatric patients.http://zjms-hmu.org/files/articles/281217015654.pdfEntrance skin dosepediatric radiologyDiagnostic X-rayRadiation protection |
spellingShingle | Rozhan Ahmad Hamad Saeed Runak Tahir Ali Assessment of entrance skin doses and radiation protection for pediatric X-ray examination Zanco Journal of Medical Sciences Entrance skin dose pediatric radiology Diagnostic X-ray Radiation protection |
title | Assessment of entrance skin doses and radiation protection for pediatric X-ray examination |
title_full | Assessment of entrance skin doses and radiation protection for pediatric X-ray examination |
title_fullStr | Assessment of entrance skin doses and radiation protection for pediatric X-ray examination |
title_full_unstemmed | Assessment of entrance skin doses and radiation protection for pediatric X-ray examination |
title_short | Assessment of entrance skin doses and radiation protection for pediatric X-ray examination |
title_sort | assessment of entrance skin doses and radiation protection for pediatric x ray examination |
topic | Entrance skin dose pediatric radiology Diagnostic X-ray Radiation protection |
url | http://zjms-hmu.org/files/articles/281217015654.pdf |
work_keys_str_mv | AT rozhanahmadhamadsaeed assessmentofentranceskindosesandradiationprotectionforpediatricxrayexamination AT runaktahirali assessmentofentranceskindosesandradiationprotectionforpediatricxrayexamination |