Performance Assessment of a Low-Cost PM<sub>2.5 </sub>Sensor for a near Four-Month Period in Oslo, Norway

The very low-cost Nova particulate matter (PM) sensor SDS011 has recently drawn attention for its use for measuring PM mass concentration, which is frequently used as an indicator of air quality. However, this sensor has not been thoroughly evaluated in real-world conditions and its data quality is...

Full description

Bibliographic Details
Main Authors: Hai-Ying Liu, Philipp Schneider, Rolf Haugen, Matthias Vogt
Format: Article
Language:English
Published: MDPI AG 2019-01-01
Series:Atmosphere
Subjects:
Online Access:https://www.mdpi.com/2073-4433/10/2/41
_version_ 1798045151170396160
author Hai-Ying Liu
Philipp Schneider
Rolf Haugen
Matthias Vogt
author_facet Hai-Ying Liu
Philipp Schneider
Rolf Haugen
Matthias Vogt
author_sort Hai-Ying Liu
collection DOAJ
description The very low-cost Nova particulate matter (PM) sensor SDS011 has recently drawn attention for its use for measuring PM mass concentration, which is frequently used as an indicator of air quality. However, this sensor has not been thoroughly evaluated in real-world conditions and its data quality is not well documented. In this study, three SDS011 sensors were evaluated by co-locating them at an official, air quality monitoring station equipped with reference-equivalent instrumentation in Oslo, Norway. The sensors’ measurement results for PM<sub>2.5 </sub>were compared with data generated from the air quality monitoring station over almost a four-month period. Five performance aspects of the sensors were examined: operational data coverage, linearity of response and accuracy, inter-sensor variability, dependence on relative humidity (RH) and temperature (T), and potential improvement of sensor accuracy, by data calibration using a machine-learning method. The results of the study are: (i) the three sensors provide quite similar results, with inter-sensor correlations exhibiting <i>R</i> values higher than 0.97; (ii) all three sensors demonstrate quite high linearity against officially measured concentrations of PM<sub>2.5</sub>, with <i>R</i><sup>2</sup> values ranging from 0.55 to 0.71; (iii) high RH (over 80%) negatively affected the sensor response; (iv) data calibration using only the RH and T recorded directly at the three sensors increased the <i>R</i><sup>2</sup> value from 0.71 to 0.80, 068 to 0.79, and 0.55 to 0.76. The results demonstrate the general feasibility of using these low cost SDS011 sensors for indicative PM<sub>2.5</sub> monitoring under certain environmental conditions. Within these constraints, they further indicate that there is potential for deploying large networks of such devices, due to the sensors’ relative accuracy, size and cost. This opens up a wide variety of applications, such as high-resolution air quality mapping and personalized air quality information services. However, it should be noted that the sensors exhibit often very high relative errors for hourly values and that there is a high potential of abusing these types of sensors if they are applied outside the manufacturer-provided specifications particularly regarding relative humidity. Furthermore, our analysis covers only a relatively short time period and it is desirable to carry out longer-term studies covering a wider range of meteorological conditions.
first_indexed 2024-04-11T23:16:03Z
format Article
id doaj.art-eb1ecbb1be0041449f6b16633760f83c
institution Directory Open Access Journal
issn 2073-4433
language English
last_indexed 2024-04-11T23:16:03Z
publishDate 2019-01-01
publisher MDPI AG
record_format Article
series Atmosphere
spelling doaj.art-eb1ecbb1be0041449f6b16633760f83c2022-12-22T03:57:38ZengMDPI AGAtmosphere2073-44332019-01-011024110.3390/atmos10020041atmos10020041Performance Assessment of a Low-Cost PM<sub>2.5 </sub>Sensor for a near Four-Month Period in Oslo, NorwayHai-Ying Liu0Philipp Schneider1Rolf Haugen2Matthias Vogt3NILU—Norwegian Institute for Air Research, Postboks 100, 2027 Kjeller, NorwayNILU—Norwegian Institute for Air Research, Postboks 100, 2027 Kjeller, NorwayNILU—Norwegian Institute for Air Research, Postboks 100, 2027 Kjeller, NorwayNILU—Norwegian Institute for Air Research, Postboks 100, 2027 Kjeller, NorwayThe very low-cost Nova particulate matter (PM) sensor SDS011 has recently drawn attention for its use for measuring PM mass concentration, which is frequently used as an indicator of air quality. However, this sensor has not been thoroughly evaluated in real-world conditions and its data quality is not well documented. In this study, three SDS011 sensors were evaluated by co-locating them at an official, air quality monitoring station equipped with reference-equivalent instrumentation in Oslo, Norway. The sensors’ measurement results for PM<sub>2.5 </sub>were compared with data generated from the air quality monitoring station over almost a four-month period. Five performance aspects of the sensors were examined: operational data coverage, linearity of response and accuracy, inter-sensor variability, dependence on relative humidity (RH) and temperature (T), and potential improvement of sensor accuracy, by data calibration using a machine-learning method. The results of the study are: (i) the three sensors provide quite similar results, with inter-sensor correlations exhibiting <i>R</i> values higher than 0.97; (ii) all three sensors demonstrate quite high linearity against officially measured concentrations of PM<sub>2.5</sub>, with <i>R</i><sup>2</sup> values ranging from 0.55 to 0.71; (iii) high RH (over 80%) negatively affected the sensor response; (iv) data calibration using only the RH and T recorded directly at the three sensors increased the <i>R</i><sup>2</sup> value from 0.71 to 0.80, 068 to 0.79, and 0.55 to 0.76. The results demonstrate the general feasibility of using these low cost SDS011 sensors for indicative PM<sub>2.5</sub> monitoring under certain environmental conditions. Within these constraints, they further indicate that there is potential for deploying large networks of such devices, due to the sensors’ relative accuracy, size and cost. This opens up a wide variety of applications, such as high-resolution air quality mapping and personalized air quality information services. However, it should be noted that the sensors exhibit often very high relative errors for hourly values and that there is a high potential of abusing these types of sensors if they are applied outside the manufacturer-provided specifications particularly regarding relative humidity. Furthermore, our analysis covers only a relatively short time period and it is desirable to carry out longer-term studies covering a wider range of meteorological conditions.https://www.mdpi.com/2073-4433/10/2/41air pollutionair quality monitoringevaluation and calibrationlow-cost sensorsNova PM sensor SDS011particulate matterPM2.5
spellingShingle Hai-Ying Liu
Philipp Schneider
Rolf Haugen
Matthias Vogt
Performance Assessment of a Low-Cost PM<sub>2.5 </sub>Sensor for a near Four-Month Period in Oslo, Norway
Atmosphere
air pollution
air quality monitoring
evaluation and calibration
low-cost sensors
Nova PM sensor SDS011
particulate matter
PM2.5
title Performance Assessment of a Low-Cost PM<sub>2.5 </sub>Sensor for a near Four-Month Period in Oslo, Norway
title_full Performance Assessment of a Low-Cost PM<sub>2.5 </sub>Sensor for a near Four-Month Period in Oslo, Norway
title_fullStr Performance Assessment of a Low-Cost PM<sub>2.5 </sub>Sensor for a near Four-Month Period in Oslo, Norway
title_full_unstemmed Performance Assessment of a Low-Cost PM<sub>2.5 </sub>Sensor for a near Four-Month Period in Oslo, Norway
title_short Performance Assessment of a Low-Cost PM<sub>2.5 </sub>Sensor for a near Four-Month Period in Oslo, Norway
title_sort performance assessment of a low cost pm sub 2 5 sub sensor for a near four month period in oslo norway
topic air pollution
air quality monitoring
evaluation and calibration
low-cost sensors
Nova PM sensor SDS011
particulate matter
PM2.5
url https://www.mdpi.com/2073-4433/10/2/41
work_keys_str_mv AT haiyingliu performanceassessmentofalowcostpmsub25subsensorforanearfourmonthperiodinoslonorway
AT philippschneider performanceassessmentofalowcostpmsub25subsensorforanearfourmonthperiodinoslonorway
AT rolfhaugen performanceassessmentofalowcostpmsub25subsensorforanearfourmonthperiodinoslonorway
AT matthiasvogt performanceassessmentofalowcostpmsub25subsensorforanearfourmonthperiodinoslonorway