Influence of temperature-dependent tissue parameters on monopolar coagulation model

The use of high-frequency (HF) generators for HF surgical treatment of biological tissue has become an indispensable part of today's surgical applications of all kinds. Generally, HF alternating electric currents between 300 kHz and 1 MHz are used to induce hemostasis by heating at the cellular...

Full description

Bibliographic Details
Main Authors: Busch Christoph, Rupitsch Stefan J., Moeller Knut
Format: Article
Language:English
Published: De Gruyter 2022-09-01
Series:Current Directions in Biomedical Engineering
Subjects:
Online Access:https://doi.org/10.1515/cdbme-2022-1119
_version_ 1811159465194422272
author Busch Christoph
Rupitsch Stefan J.
Moeller Knut
author_facet Busch Christoph
Rupitsch Stefan J.
Moeller Knut
author_sort Busch Christoph
collection DOAJ
description The use of high-frequency (HF) generators for HF surgical treatment of biological tissue has become an indispensable part of today's surgical applications of all kinds. Generally, HF alternating electric currents between 300 kHz and 1 MHz are used to induce hemostasis by heating at the cellular level. This effect can be attributed to Joule heating, in which a current dissipated conductor converts the electrical energy into thermal energy. However, sound evidence on the reliability and effectiveness of application-specific HF generator modes is not sufficiently available. Usually, the evidence takes place empirically by means of preclinical or clinical studies. Nevertheless, a corresponding empirical data collection is time- and cost-intensive. Therefore, physiological and statistical modeling provides the opportunity to relate tissue response to the applied electrical energy to obtain a prediction of the tissue reaction. In this contribution, we establish a monopolar coagulation model of an already well-known model approach based on Pennes bioheat equation. Additionally, the vaporization of tissue water at the water boiling point is considered. Furthermore, a variation of temperature-dependent tissue parameters was performed to analyze their impact on the model output. The simulation results demonstrate that the initial electrical conductivity has the greatest influence on the temperature distribution as well as on the time until the tissue temperature reached the boiling point of water. In contrast, the tissue water content has the least impact on the model output. Depending on the desired coagulation effect, HF power control as a function of electrical conductivity or its reciprocal, tissue resistance, must be added next in an improved model.
first_indexed 2024-04-10T05:41:34Z
format Article
id doaj.art-eb256d4306914682b0051f6e0b9b2e22
institution Directory Open Access Journal
issn 2364-5504
language English
last_indexed 2024-04-10T05:41:34Z
publishDate 2022-09-01
publisher De Gruyter
record_format Article
series Current Directions in Biomedical Engineering
spelling doaj.art-eb256d4306914682b0051f6e0b9b2e222023-03-06T10:24:52ZengDe GruyterCurrent Directions in Biomedical Engineering2364-55042022-09-018246646910.1515/cdbme-2022-1119Influence of temperature-dependent tissue parameters on monopolar coagulation modelBusch Christoph0Rupitsch Stefan J.1Moeller Knut2Furtwangen University, Institute of Technical Medicine, 78054 Villingen-Schwenningen, GermanyDepartment of Microsystems Engineering, Georges-Köhler-Allee 106,Freiburg im Breisgau, GermanyFurtwangen University, Institute of Technical Medicine, 78054Villingen-Schwenningen, GermanyThe use of high-frequency (HF) generators for HF surgical treatment of biological tissue has become an indispensable part of today's surgical applications of all kinds. Generally, HF alternating electric currents between 300 kHz and 1 MHz are used to induce hemostasis by heating at the cellular level. This effect can be attributed to Joule heating, in which a current dissipated conductor converts the electrical energy into thermal energy. However, sound evidence on the reliability and effectiveness of application-specific HF generator modes is not sufficiently available. Usually, the evidence takes place empirically by means of preclinical or clinical studies. Nevertheless, a corresponding empirical data collection is time- and cost-intensive. Therefore, physiological and statistical modeling provides the opportunity to relate tissue response to the applied electrical energy to obtain a prediction of the tissue reaction. In this contribution, we establish a monopolar coagulation model of an already well-known model approach based on Pennes bioheat equation. Additionally, the vaporization of tissue water at the water boiling point is considered. Furthermore, a variation of temperature-dependent tissue parameters was performed to analyze their impact on the model output. The simulation results demonstrate that the initial electrical conductivity has the greatest influence on the temperature distribution as well as on the time until the tissue temperature reached the boiling point of water. In contrast, the tissue water content has the least impact on the model output. Depending on the desired coagulation effect, HF power control as a function of electrical conductivity or its reciprocal, tissue resistance, must be added next in an improved model.https://doi.org/10.1515/cdbme-2022-1119monopolar coagulationhf modelingfem simulationtemperature-dependent tissue parameter
spellingShingle Busch Christoph
Rupitsch Stefan J.
Moeller Knut
Influence of temperature-dependent tissue parameters on monopolar coagulation model
Current Directions in Biomedical Engineering
monopolar coagulation
hf modeling
fem simulation
temperature-dependent tissue parameter
title Influence of temperature-dependent tissue parameters on monopolar coagulation model
title_full Influence of temperature-dependent tissue parameters on monopolar coagulation model
title_fullStr Influence of temperature-dependent tissue parameters on monopolar coagulation model
title_full_unstemmed Influence of temperature-dependent tissue parameters on monopolar coagulation model
title_short Influence of temperature-dependent tissue parameters on monopolar coagulation model
title_sort influence of temperature dependent tissue parameters on monopolar coagulation model
topic monopolar coagulation
hf modeling
fem simulation
temperature-dependent tissue parameter
url https://doi.org/10.1515/cdbme-2022-1119
work_keys_str_mv AT buschchristoph influenceoftemperaturedependenttissueparametersonmonopolarcoagulationmodel
AT rupitschstefanj influenceoftemperaturedependenttissueparametersonmonopolarcoagulationmodel
AT moellerknut influenceoftemperaturedependenttissueparametersonmonopolarcoagulationmodel