Polyvinyl chloride-based 18-crown-6, dibenzo18-crown-6 and calix-[6]-arene zinc(II)-potentiometric sensors

Polyvinyl chloride (PVC) based membranes of 18-crown-6 (18C6), dibenzo 18-crowen-6 (DB18C6) and calix[6]arene (CAX), as ionophores, with dioctylphenylphosphonate (DOPP), bis(ethylhexyl)sebacate (DOS) dioctyl phthalate (DOP), 2-nitrophenyloctylether (o-NPOE) and didecylphthalate (DDP) as plasticizing...

Full description

Bibliographic Details
Main Authors: Magda A. Akl, Mohammed H. Abd El-Aziz
Format: Article
Language:English
Published: Elsevier 2016-09-01
Series:Arabian Journal of Chemistry
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1878535211002504
_version_ 1818559580291989504
author Magda A. Akl
Mohammed H. Abd El-Aziz
author_facet Magda A. Akl
Mohammed H. Abd El-Aziz
author_sort Magda A. Akl
collection DOAJ
description Polyvinyl chloride (PVC) based membranes of 18-crown-6 (18C6), dibenzo 18-crowen-6 (DB18C6) and calix[6]arene (CAX), as ionophores, with dioctylphenylphosphonate (DOPP), bis(ethylhexyl)sebacate (DOS) dioctyl phthalate (DOP), 2-nitrophenyloctylether (o-NPOE) and didecylphthalate (DDP) as plasticizing solvent mediators are prepared and constructed for the determination of Zn(II). Of the 15 membranes constructed, only the PVC based membranes of DB18C6 and 18C6 ionophores with DOPP, as plasticizer, in the ratio (w/w) PVC:ionophore:DOPP (60:2:120) give the best results in terms of working concentration range (1.0 × 10−5–1.0 × 10−1 M) with a Nernstian slope of 29.0 mV/decade of activity for membrane composed of DOPP + DB18C6(1a) and (1.0 × 10−5–1.0 × 10−1 M) with a Nernstian slope of 30.0 mV/decade of activity for membrane composed of DOPP + 18C6(1b). The usable pH range of the sensors is 3.0–8.0, beyond which a drift in potential is observed. The response time of the sensors is ⩽15 s with a lifetime of 2 months during which they can be used without any measurable divergence. The selectivity coefficient values indicate that the electrode is highly selective for Zn2+ over a number of other cations except Pb2+ and Ag+. The electrodes have successfully been used to determine Zn(II) in real alloys and standard samples with a precision as relative standard deviation (RSD) <2% for each of the cited electrodes. The results obtained by the proposed ISEs are in good agreement with the results obtained by direct flame AAS method.
first_indexed 2024-12-14T00:27:23Z
format Article
id doaj.art-eb409640695148468dac1bca1be379b9
institution Directory Open Access Journal
issn 1878-5352
language English
last_indexed 2024-12-14T00:27:23Z
publishDate 2016-09-01
publisher Elsevier
record_format Article
series Arabian Journal of Chemistry
spelling doaj.art-eb409640695148468dac1bca1be379b92022-12-21T23:25:00ZengElsevierArabian Journal of Chemistry1878-53522016-09-019S1S878S88810.1016/j.arabjc.2011.09.009Polyvinyl chloride-based 18-crown-6, dibenzo18-crown-6 and calix-[6]-arene zinc(II)-potentiometric sensorsMagda A. Akl0Mohammed H. Abd El-Aziz1Department of Chemistry, Faculty of Science, Mansoura University, Mansoura, EgyptCentral Laboratory, Egyptian Railways, EgyptPolyvinyl chloride (PVC) based membranes of 18-crown-6 (18C6), dibenzo 18-crowen-6 (DB18C6) and calix[6]arene (CAX), as ionophores, with dioctylphenylphosphonate (DOPP), bis(ethylhexyl)sebacate (DOS) dioctyl phthalate (DOP), 2-nitrophenyloctylether (o-NPOE) and didecylphthalate (DDP) as plasticizing solvent mediators are prepared and constructed for the determination of Zn(II). Of the 15 membranes constructed, only the PVC based membranes of DB18C6 and 18C6 ionophores with DOPP, as plasticizer, in the ratio (w/w) PVC:ionophore:DOPP (60:2:120) give the best results in terms of working concentration range (1.0 × 10−5–1.0 × 10−1 M) with a Nernstian slope of 29.0 mV/decade of activity for membrane composed of DOPP + DB18C6(1a) and (1.0 × 10−5–1.0 × 10−1 M) with a Nernstian slope of 30.0 mV/decade of activity for membrane composed of DOPP + 18C6(1b). The usable pH range of the sensors is 3.0–8.0, beyond which a drift in potential is observed. The response time of the sensors is ⩽15 s with a lifetime of 2 months during which they can be used without any measurable divergence. The selectivity coefficient values indicate that the electrode is highly selective for Zn2+ over a number of other cations except Pb2+ and Ag+. The electrodes have successfully been used to determine Zn(II) in real alloys and standard samples with a precision as relative standard deviation (RSD) <2% for each of the cited electrodes. The results obtained by the proposed ISEs are in good agreement with the results obtained by direct flame AAS method.http://www.sciencedirect.com/science/article/pii/S1878535211002504Crown ethersZincIon selective electrodesCalix-[6]areneAlloys
spellingShingle Magda A. Akl
Mohammed H. Abd El-Aziz
Polyvinyl chloride-based 18-crown-6, dibenzo18-crown-6 and calix-[6]-arene zinc(II)-potentiometric sensors
Arabian Journal of Chemistry
Crown ethers
Zinc
Ion selective electrodes
Calix-[6]arene
Alloys
title Polyvinyl chloride-based 18-crown-6, dibenzo18-crown-6 and calix-[6]-arene zinc(II)-potentiometric sensors
title_full Polyvinyl chloride-based 18-crown-6, dibenzo18-crown-6 and calix-[6]-arene zinc(II)-potentiometric sensors
title_fullStr Polyvinyl chloride-based 18-crown-6, dibenzo18-crown-6 and calix-[6]-arene zinc(II)-potentiometric sensors
title_full_unstemmed Polyvinyl chloride-based 18-crown-6, dibenzo18-crown-6 and calix-[6]-arene zinc(II)-potentiometric sensors
title_short Polyvinyl chloride-based 18-crown-6, dibenzo18-crown-6 and calix-[6]-arene zinc(II)-potentiometric sensors
title_sort polyvinyl chloride based 18 crown 6 dibenzo18 crown 6 and calix 6 arene zinc ii potentiometric sensors
topic Crown ethers
Zinc
Ion selective electrodes
Calix-[6]arene
Alloys
url http://www.sciencedirect.com/science/article/pii/S1878535211002504
work_keys_str_mv AT magdaaakl polyvinylchloridebased18crown6dibenzo18crown6andcalix6arenezinciipotentiometricsensors
AT mohammedhabdelaziz polyvinylchloridebased18crown6dibenzo18crown6andcalix6arenezinciipotentiometricsensors