USE A CU STOM-MAD E CAD PROBE HOLDERS FOR PERIODONTAL MICROCIRCU LATION ASSESSMENT BY LASER DOPPLER FLOWMETRY

Objective: To perform laser Doppler flowmetry (LDF) periodontal microcirculation assessment using custom-made, computer-aided-designed probe holders manufactured by stereolithography (SLA). Methods: 66 young people aged 21-23 years old with clinically healthy periodontium were examined. The first g...

Full description

Bibliographic Details
Main Authors: A. A. FLENKIN, S.N. ERMOLYEV
Format: Article
Language:English
Published: Avicenna Tajik State Medical University 2022-03-01
Series:Паёми Сино
Subjects:
Online Access:https://doi.org/10.25005/2074-0581-2022-24-1-59-65
_version_ 1797806001776230400
author A. A. FLENKIN
S.N. ERMOLYEV
author_facet A. A. FLENKIN
S.N. ERMOLYEV
author_sort A. A. FLENKIN
collection DOAJ
description Objective: To perform laser Doppler flowmetry (LDF) periodontal microcirculation assessment using custom-made, computer-aided-designed probe holders manufactured by stereolithography (SLA). Methods: 66 young people aged 21-23 years old with clinically healthy periodontium were examined. The first group consisted of subjects where a custom-made probe holder was fabricated using a silicone impression mould technique. The second group consisted of subjects where a custom-made computer-aided-design probe holder made of a photopolymer by SLA was used. The basic microcirculation parameters were analysed to evaluate periodontal microcirculation by the LDF method: the PM – average perfusion value in periodontal tissues; δ – the average square deviation of the amplitude of blood flow fluctuations from the arithmetic mean value, Kv – coefficient of variation (%). Statistical processing of the results was carried out using the software package Statistica 13.0 (StatSoft Inc, USA). Results: Statistical analysis results indicated that the functional characteristics of the periodontal microcirculation using various custom-made fibre optic probe holders used in capillary blood flow monitoring had significant differences p<0.05. The value of the median PM when using a silicone holder in group I was 1.6 times lower than when using a photopolymer holder in group II. The median value of the σ index when using a silicone holder in group I was 2.3 times higher than when using a photopolymer holder in group II. The median value of the Kv when using a silicone holder in group I was 2.5 times higher than when using a photopolymer holder in group II. Conclusion: A photopolymer probe holder, unlike a silicone one, provides a constant fixed distance between the periodontal tissues and the LDF probe, prevents movement or probe displacement, and makes it possible to avoid pressure on the gingival tissue, ensuring high accuracy of laser diagnostics
first_indexed 2024-03-13T06:00:39Z
format Article
id doaj.art-eb416ea2e4ab477e9f417fd52ff1c19b
institution Directory Open Access Journal
issn 2074-0581
2959-6327
language English
last_indexed 2024-03-13T06:00:39Z
publishDate 2022-03-01
publisher Avicenna Tajik State Medical University
record_format Article
series Паёми Сино
spelling doaj.art-eb416ea2e4ab477e9f417fd52ff1c19b2023-06-12T17:26:58ZengAvicenna Tajik State Medical UniversityПаёми Сино2074-05812959-63272022-03-01241596510.25005/2074-0581-2022-24-1-59-65USE A CU STOM-MAD E CAD PROBE HOLDERS FOR PERIODONTAL MICROCIRCU LATION ASSESSMENT BY LASER DOPPLER FLOWMETRYA. A. FLENKIN0S.N. ERMOLYEV1Department of Periodontology, Moscow State University of Medicine and Dentistry named after A. I. Evdokimov, Moscow, Russian FederationDepartment of Periodontology, Moscow State University of Medicine and Dentistry named after A. I. Evdokimov, Moscow, Russian FederationObjective: To perform laser Doppler flowmetry (LDF) periodontal microcirculation assessment using custom-made, computer-aided-designed probe holders manufactured by stereolithography (SLA). Methods: 66 young people aged 21-23 years old with clinically healthy periodontium were examined. The first group consisted of subjects where a custom-made probe holder was fabricated using a silicone impression mould technique. The second group consisted of subjects where a custom-made computer-aided-design probe holder made of a photopolymer by SLA was used. The basic microcirculation parameters were analysed to evaluate periodontal microcirculation by the LDF method: the PM – average perfusion value in periodontal tissues; δ – the average square deviation of the amplitude of blood flow fluctuations from the arithmetic mean value, Kv – coefficient of variation (%). Statistical processing of the results was carried out using the software package Statistica 13.0 (StatSoft Inc, USA). Results: Statistical analysis results indicated that the functional characteristics of the periodontal microcirculation using various custom-made fibre optic probe holders used in capillary blood flow monitoring had significant differences p<0.05. The value of the median PM when using a silicone holder in group I was 1.6 times lower than when using a photopolymer holder in group II. The median value of the σ index when using a silicone holder in group I was 2.3 times higher than when using a photopolymer holder in group II. The median value of the Kv when using a silicone holder in group I was 2.5 times higher than when using a photopolymer holder in group II. Conclusion: A photopolymer probe holder, unlike a silicone one, provides a constant fixed distance between the periodontal tissues and the LDF probe, prevents movement or probe displacement, and makes it possible to avoid pressure on the gingival tissue, ensuring high accuracy of laser diagnosticshttps://doi.org/10.25005/2074-0581-2022-24-1-59-65functional diagnosticsldfmicrocirculationperiodontiumcadstereolithography.
spellingShingle A. A. FLENKIN
S.N. ERMOLYEV
USE A CU STOM-MAD E CAD PROBE HOLDERS FOR PERIODONTAL MICROCIRCU LATION ASSESSMENT BY LASER DOPPLER FLOWMETRY
Паёми Сино
functional diagnostics
ldf
microcirculation
periodontium
cad
stereolithography.
title USE A CU STOM-MAD E CAD PROBE HOLDERS FOR PERIODONTAL MICROCIRCU LATION ASSESSMENT BY LASER DOPPLER FLOWMETRY
title_full USE A CU STOM-MAD E CAD PROBE HOLDERS FOR PERIODONTAL MICROCIRCU LATION ASSESSMENT BY LASER DOPPLER FLOWMETRY
title_fullStr USE A CU STOM-MAD E CAD PROBE HOLDERS FOR PERIODONTAL MICROCIRCU LATION ASSESSMENT BY LASER DOPPLER FLOWMETRY
title_full_unstemmed USE A CU STOM-MAD E CAD PROBE HOLDERS FOR PERIODONTAL MICROCIRCU LATION ASSESSMENT BY LASER DOPPLER FLOWMETRY
title_short USE A CU STOM-MAD E CAD PROBE HOLDERS FOR PERIODONTAL MICROCIRCU LATION ASSESSMENT BY LASER DOPPLER FLOWMETRY
title_sort use a cu stom mad e cad probe holders for periodontal microcircu lation assessment by laser doppler flowmetry
topic functional diagnostics
ldf
microcirculation
periodontium
cad
stereolithography.
url https://doi.org/10.25005/2074-0581-2022-24-1-59-65
work_keys_str_mv AT aaflenkin useacustommadecadprobeholdersforperiodontalmicrocirculationassessmentbylaserdopplerflowmetry
AT snermolyev useacustommadecadprobeholdersforperiodontalmicrocirculationassessmentbylaserdopplerflowmetry