PRIMING OF A LOW CAPACITY WASTE WATER TREATEMENT PLANT

In wastewater treatment plants, secondary biologic treatment is generally compulsory for the localities having less than 10,000 equivalent inhabitants, with a supplementary removal of nutrients if the area is a sensitive one. For the areas which are not suitable for centralized household used water...

Full description

Bibliographic Details
Main Authors: Nicoleta Luminiţa Jurj, Georgeta Burtica, Marcel Murariu, Elena Săvescu, Ladislau Klein
Format: Article
Language:English
Published: Sciendo 2012-12-01
Series:Studia Universitatis Vasile Goldis Arad, Seria Stiinte Economice
Subjects:
Online Access:http://studiaeconomia.uvvg.ro/index.php?option=com_content&view=article&id=283:priming-of-a-low-capacity-waste-water-treatement-plant&catid=40:2012-partea-4&Itemid=71
_version_ 1798039751662501888
author Nicoleta Luminiţa Jurj
Georgeta Burtica
Marcel Murariu
Elena Săvescu
Ladislau Klein
author_facet Nicoleta Luminiţa Jurj
Georgeta Burtica
Marcel Murariu
Elena Săvescu
Ladislau Klein
author_sort Nicoleta Luminiţa Jurj
collection DOAJ
description In wastewater treatment plants, secondary biologic treatment is generally compulsory for the localities having less than 10,000 equivalent inhabitants, with a supplementary removal of nutrients if the area is a sensitive one. For the areas which are not suitable for centralized household used water collecting network individual treatment devices or collective low capacity devices are recommended. For certain settlements, for instance for the mountainous dispersed villages, or for detached individual households or farms the collective devices can not be an economic solution as involves high maintenance costs and exploiting problems due to long pipes for low flow rates. Priming is one of the starting up processes of a waste water treatment plant. This is not a very difficult process and requires no specialized staff. However, for helping the owners of a low capacity treatment plant, priming of ORM 5 type mechanical - biological equipment consisting in a tank with four compartments, designed for five equivalent inhabitants was studied inside the plant of Timisoara municipality. For the experimental tests waste water from the Timisoara city sewage network was used. This is mixed waste water resulted from faecal/domestic, industrial and rain water. The study comprised tests in unfavorable technological conditions. The conclusions of the monitoring process underline the need of control of the aeration process and the negative technological and consequently the negative economic effect of the less effective process control.
first_indexed 2024-04-11T21:58:04Z
format Article
id doaj.art-eb8b64dab9a24c84be77dd31fbfd26c0
institution Directory Open Access Journal
issn 1584-2339
2285-3065
language English
last_indexed 2024-04-11T21:58:04Z
publishDate 2012-12-01
publisher Sciendo
record_format Article
series Studia Universitatis Vasile Goldis Arad, Seria Stiinte Economice
spelling doaj.art-eb8b64dab9a24c84be77dd31fbfd26c02022-12-22T04:01:02ZengSciendoStudia Universitatis Vasile Goldis Arad, Seria Stiinte Economice1584-23392285-30652012-12-01224108118PRIMING OF A LOW CAPACITY WASTE WATER TREATEMENT PLANTNicoleta Luminiţa Jurj0Georgeta Burtica1Marcel Murariu2Elena Săvescu3Ladislau Klein4Universitatea „Politehnica” TimişoaraUniversitatea „Politehnica” TimişoaraUniversitatea „Politehnica” TimişoaraSC AQUATIM SA..TimisoaraUniversitatea de Vest „ V Goldis” AradIn wastewater treatment plants, secondary biologic treatment is generally compulsory for the localities having less than 10,000 equivalent inhabitants, with a supplementary removal of nutrients if the area is a sensitive one. For the areas which are not suitable for centralized household used water collecting network individual treatment devices or collective low capacity devices are recommended. For certain settlements, for instance for the mountainous dispersed villages, or for detached individual households or farms the collective devices can not be an economic solution as involves high maintenance costs and exploiting problems due to long pipes for low flow rates. Priming is one of the starting up processes of a waste water treatment plant. This is not a very difficult process and requires no specialized staff. However, for helping the owners of a low capacity treatment plant, priming of ORM 5 type mechanical - biological equipment consisting in a tank with four compartments, designed for five equivalent inhabitants was studied inside the plant of Timisoara municipality. For the experimental tests waste water from the Timisoara city sewage network was used. This is mixed waste water resulted from faecal/domestic, industrial and rain water. The study comprised tests in unfavorable technological conditions. The conclusions of the monitoring process underline the need of control of the aeration process and the negative technological and consequently the negative economic effect of the less effective process control.http://studiaeconomia.uvvg.ro/index.php?option=com_content&view=article&id=283:priming-of-a-low-capacity-waste-water-treatement-plant&catid=40:2012-partea-4&Itemid=71wastewater treatmentplantpilotpriming
spellingShingle Nicoleta Luminiţa Jurj
Georgeta Burtica
Marcel Murariu
Elena Săvescu
Ladislau Klein
PRIMING OF A LOW CAPACITY WASTE WATER TREATEMENT PLANT
Studia Universitatis Vasile Goldis Arad, Seria Stiinte Economice
wastewater treatment
plant
pilot
priming
title PRIMING OF A LOW CAPACITY WASTE WATER TREATEMENT PLANT
title_full PRIMING OF A LOW CAPACITY WASTE WATER TREATEMENT PLANT
title_fullStr PRIMING OF A LOW CAPACITY WASTE WATER TREATEMENT PLANT
title_full_unstemmed PRIMING OF A LOW CAPACITY WASTE WATER TREATEMENT PLANT
title_short PRIMING OF A LOW CAPACITY WASTE WATER TREATEMENT PLANT
title_sort priming of a low capacity waste water treatement plant
topic wastewater treatment
plant
pilot
priming
url http://studiaeconomia.uvvg.ro/index.php?option=com_content&view=article&id=283:priming-of-a-low-capacity-waste-water-treatement-plant&catid=40:2012-partea-4&Itemid=71
work_keys_str_mv AT nicoletaluminitajurj primingofalowcapacitywastewatertreatementplant
AT georgetaburtica primingofalowcapacitywastewatertreatementplant
AT marcelmurariu primingofalowcapacitywastewatertreatementplant
AT elenasavescu primingofalowcapacitywastewatertreatementplant
AT ladislauklein primingofalowcapacitywastewatertreatementplant