Overhead power lines magnetic field reducing in multi-story building by active shielding means
Aim. Reducing of magnetic flux density of magnetic field in multi-storey building, generated by overhead power lines to the sanitary standards level by active shielding means. The tasks of the work are the synthesis, computer simulation and experimental research of three-circuits system of active sh...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
National Technical University "Kharkiv Polytechnic Institute"
2021-04-01
|
Series: | Electrical engineering & Electromechanics |
Subjects: | |
Online Access: | http://eie.khpi.edu.ua/article/view/228885/227897 |
_version_ | 1818347007484362752 |
---|---|
author | B. I. Kuznetsov T. B. Nikitina I. V. Bovdui V. V. Kolomiets B. B. Kobylianskiy |
author_facet | B. I. Kuznetsov T. B. Nikitina I. V. Bovdui V. V. Kolomiets B. B. Kobylianskiy |
author_sort | B. I. Kuznetsov |
collection | DOAJ |
description | Aim. Reducing of magnetic flux density of magnetic field in multi-storey building, generated by overhead power lines to the sanitary standards level by active shielding means. The tasks of the work are the synthesis, computer simulation and experimental research of three-circuits system of active shielding, which includes three shielding coils. Methodology. When synthesizing the system of active shielding of magnetic field, are determined their number, configuration, spatial arrangement and of shielding coils as well as the shielding coils currents and resulting magnetic flux density value in the shielding space. The synthesis is based on the multi-criteria game decision, in which the payoff vector is calculated on the basis on quasi-stationary approximation solutions of the Maxwell equations. The game decision is based on the stochastic particles multiswarm optimization algorithms. Results. Computer simulation and experimental research of three-circuit system of active shielding of magnetic field, generated by overhead power lines with phase conductors triangle arrangements in multi-storey building are given. The possibility of initial magnetic flux density level reducing in multi-storey building to the sanitary standards level is shown. Originality. For the first time to reducing of magnetic flux density of magnetic field in multi-storey building the synthesis, computer simulation and experimental research of three-circuit system of active shielding of magnetic field generated by single-circuit overhead power line with phase conductors triangular arrangements carried out. Practical value. Practical recommendations from the point of view of the practical implementation on reasonable choice of the spatial arrangement of three shielding coils of three-circuit system of active shielding of the magnetic field generated by single-circuit overhead power line with phase conductors triangular arrangements in multi-storey building are given. |
first_indexed | 2024-12-13T17:27:19Z |
format | Article |
id | doaj.art-ebc4b27c6f1a4569aecbc18a37e1f5df |
institution | Directory Open Access Journal |
issn | 2074-272X 2309-3404 |
language | English |
last_indexed | 2024-12-13T17:27:19Z |
publishDate | 2021-04-01 |
publisher | National Technical University "Kharkiv Polytechnic Institute" |
record_format | Article |
series | Electrical engineering & Electromechanics |
spelling | doaj.art-ebc4b27c6f1a4569aecbc18a37e1f5df2022-12-21T23:37:10ZengNational Technical University "Kharkiv Polytechnic Institute"Electrical engineering & Electromechanics2074-272X2309-34042021-04-012232910.20998/2074-272X.2021.2.04Overhead power lines magnetic field reducing in multi-story building by active shielding meansB. I. Kuznetsov0https://orcid.org/0000-0002-1100-095XT. B. Nikitina1https://orcid.org/0000-0002-9826-1123I. V. Bovdui2https://orcid.org/0000-0003-3508-9781V. V. Kolomiets3https://orcid.org/0000-0002-9073-5793B. B. Kobylianskiy4https://orcid.org/0000-0003-3226-5997State Institution «Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine», UkraineKharkov National Automobile and Highway University, UkraineState Institution «Institute of Technical Problems of Magnetism of the National Academy of Sciences of Ukraine», UkraineEducational scientific professional pedagogical Institute of Ukrainian Engineering Pedagogical Academy, UkraineEducational scientific professional pedagogical Institute of Ukrainian Engineering Pedagogical Academy, UkraineAim. Reducing of magnetic flux density of magnetic field in multi-storey building, generated by overhead power lines to the sanitary standards level by active shielding means. The tasks of the work are the synthesis, computer simulation and experimental research of three-circuits system of active shielding, which includes three shielding coils. Methodology. When synthesizing the system of active shielding of magnetic field, are determined their number, configuration, spatial arrangement and of shielding coils as well as the shielding coils currents and resulting magnetic flux density value in the shielding space. The synthesis is based on the multi-criteria game decision, in which the payoff vector is calculated on the basis on quasi-stationary approximation solutions of the Maxwell equations. The game decision is based on the stochastic particles multiswarm optimization algorithms. Results. Computer simulation and experimental research of three-circuit system of active shielding of magnetic field, generated by overhead power lines with phase conductors triangle arrangements in multi-storey building are given. The possibility of initial magnetic flux density level reducing in multi-storey building to the sanitary standards level is shown. Originality. For the first time to reducing of magnetic flux density of magnetic field in multi-storey building the synthesis, computer simulation and experimental research of three-circuit system of active shielding of magnetic field generated by single-circuit overhead power line with phase conductors triangular arrangements carried out. Practical value. Practical recommendations from the point of view of the practical implementation on reasonable choice of the spatial arrangement of three shielding coils of three-circuit system of active shielding of the magnetic field generated by single-circuit overhead power line with phase conductors triangular arrangements in multi-storey building are given.http://eie.khpi.edu.ua/article/view/228885/227897overhead power lines with phase conductors triangle arrangementsmagnetic fieldsystem of active shieldingcomputer simulationexperimental research |
spellingShingle | B. I. Kuznetsov T. B. Nikitina I. V. Bovdui V. V. Kolomiets B. B. Kobylianskiy Overhead power lines magnetic field reducing in multi-story building by active shielding means Electrical engineering & Electromechanics overhead power lines with phase conductors triangle arrangements magnetic field system of active shielding computer simulation experimental research |
title | Overhead power lines magnetic field reducing in multi-story building by active shielding means |
title_full | Overhead power lines magnetic field reducing in multi-story building by active shielding means |
title_fullStr | Overhead power lines magnetic field reducing in multi-story building by active shielding means |
title_full_unstemmed | Overhead power lines magnetic field reducing in multi-story building by active shielding means |
title_short | Overhead power lines magnetic field reducing in multi-story building by active shielding means |
title_sort | overhead power lines magnetic field reducing in multi story building by active shielding means |
topic | overhead power lines with phase conductors triangle arrangements magnetic field system of active shielding computer simulation experimental research |
url | http://eie.khpi.edu.ua/article/view/228885/227897 |
work_keys_str_mv | AT bikuznetsov overheadpowerlinesmagneticfieldreducinginmultistorybuildingbyactiveshieldingmeans AT tbnikitina overheadpowerlinesmagneticfieldreducinginmultistorybuildingbyactiveshieldingmeans AT ivbovdui overheadpowerlinesmagneticfieldreducinginmultistorybuildingbyactiveshieldingmeans AT vvkolomiets overheadpowerlinesmagneticfieldreducinginmultistorybuildingbyactiveshieldingmeans AT bbkobylianskiy overheadpowerlinesmagneticfieldreducinginmultistorybuildingbyactiveshieldingmeans |