Single Biotenodesis Screw vs Biotenodesis Screw with Cortical Button Tension Slide Technique for Flexor Hallucis Longus Transfer: A Biomechanical Analysis

Category: Ankle; Hindfoot; Sports; Other Introduction/Purpose: Restoration of functional plantarflexion of the ankle joint following chronic Achilles injury is achieved through transfer of the flexor hallucis longus (FHL) tendon. Fixation of the FHL tendon transfer with a cortical button tension sli...

Full description

Bibliographic Details
Main Authors: Kaitlin C. Neary MD, Sarah J. McClish, Anthony N. Khoury, Nick Denove, Coen A. Wijdicks
Format: Article
Language:English
Published: SAGE Publishing 2022-01-01
Series:Foot & Ankle Orthopaedics
Online Access:https://doi.org/10.1177/2473011421S00374
_version_ 1819279294686298112
author Kaitlin C. Neary MD
Sarah J. McClish
Anthony N. Khoury
Nick Denove
Coen A. Wijdicks
author_facet Kaitlin C. Neary MD
Sarah J. McClish
Anthony N. Khoury
Nick Denove
Coen A. Wijdicks
author_sort Kaitlin C. Neary MD
collection DOAJ
description Category: Ankle; Hindfoot; Sports; Other Introduction/Purpose: Restoration of functional plantarflexion of the ankle joint following chronic Achilles injury is achieved through transfer of the flexor hallucis longus (FHL) tendon. Fixation of the FHL tendon transfer with a cortical button tension slide technique is an advancement that has not been measured against traditional methods. The purpose of this study is to evaluate the biomechanical differences between a single biotenodesis screw versus biotenodesis screw with cortical button tension slide technique for the fixation of FHL transfer. The authors hypothesize a biomechanical advantage for the tension slide technique compared to the biotenodesis screw alone for fixation of the flexor hallucis longus in chronic Achilles pathology. Methods: 12 pairs (n=24) of fresh-frozen cadaveric tibia-to-toe samples (6 male, 6 female) were utilized to assess the biomechanics of FHL tendon transfer fixation. All specimens underwent bone density analysis. Each pair of cadaveric samples were randomized to receive either the biotenodesis screw or the tension slide technique. FHL tendon transfer was performed via standard technique using a 6.25x15mm biotenodesis screw with the foot in 20 degrees plantarflexion. A 2.6x12mm cortical button was inserted and FHL tendon was introduced with a tension-slide technique. Biomechanical loading was applied between 20N and 60N at a rate of 1Hz for 100 cycles. Post-cyclic load to failure occurred at 1.25mm/sec. Cyclic displacement, structural stiffness, and ultimate load were derived from resultant load-displacement curves. Student t-tests were used to evaluate significant effects between both FHL tendon transfer techniques. Linear regression analysis was performed to assess interactions between bone density and strength of FHL tendon transfer. Results: Average tendon diameter of the 24 FHL samples was 5.44+-0.46 mm. Average bone density for all 24 calcaneus samples was determined to be 1.06+-0.08 g/cm 2 . Loading data was normalized with respect to bone density and tendon diameter to account for inherent anatomical differences between cadaveric specimens. The addition of a cortical button for FHL transfer to the calcaneus did not significantly affect cyclic displacement (0.78+-0.52mm vs 0.87+-0.80mm) or structural stiffness (162.11+- 43.34N/mm vs. 167.57+-49.19N/mm). Addition of the cortical button to the FHL tendon transfer construct resulted in a 34% significant increase in ultimate load (343.72+-68.93 N) compared to biotenodesis screw alone (255.62+-77.17 N) (p=0.0002). Linear regression analyses did not reveal any significant interactions between bone density and FHL tendon transfer technique. Conclusion: Enhanced strength can be achieved for Achilles pathology repaired with FHL tendon transfer utilizing a biotenodesis screw and cortical button tension slide technique demonstrated by a statistically significant 34% increase in ultimate load, subsequent to cyclic loading. Cortical buttons in the setting of FHL tendon transfer to the calcaneus offers an additional level of support in the case of extreme tendon transfer failure.
first_indexed 2024-12-24T00:25:37Z
format Article
id doaj.art-ebd4eaf233934f66821943d37330eef8
institution Directory Open Access Journal
issn 2473-0114
language English
last_indexed 2024-12-24T00:25:37Z
publishDate 2022-01-01
publisher SAGE Publishing
record_format Article
series Foot & Ankle Orthopaedics
spelling doaj.art-ebd4eaf233934f66821943d37330eef82022-12-21T17:24:29ZengSAGE PublishingFoot & Ankle Orthopaedics2473-01142022-01-01710.1177/2473011421S00374Single Biotenodesis Screw vs Biotenodesis Screw with Cortical Button Tension Slide Technique for Flexor Hallucis Longus Transfer: A Biomechanical AnalysisKaitlin C. Neary MDSarah J. McClishAnthony N. KhouryNick DenoveCoen A. WijdicksCategory: Ankle; Hindfoot; Sports; Other Introduction/Purpose: Restoration of functional plantarflexion of the ankle joint following chronic Achilles injury is achieved through transfer of the flexor hallucis longus (FHL) tendon. Fixation of the FHL tendon transfer with a cortical button tension slide technique is an advancement that has not been measured against traditional methods. The purpose of this study is to evaluate the biomechanical differences between a single biotenodesis screw versus biotenodesis screw with cortical button tension slide technique for the fixation of FHL transfer. The authors hypothesize a biomechanical advantage for the tension slide technique compared to the biotenodesis screw alone for fixation of the flexor hallucis longus in chronic Achilles pathology. Methods: 12 pairs (n=24) of fresh-frozen cadaveric tibia-to-toe samples (6 male, 6 female) were utilized to assess the biomechanics of FHL tendon transfer fixation. All specimens underwent bone density analysis. Each pair of cadaveric samples were randomized to receive either the biotenodesis screw or the tension slide technique. FHL tendon transfer was performed via standard technique using a 6.25x15mm biotenodesis screw with the foot in 20 degrees plantarflexion. A 2.6x12mm cortical button was inserted and FHL tendon was introduced with a tension-slide technique. Biomechanical loading was applied between 20N and 60N at a rate of 1Hz for 100 cycles. Post-cyclic load to failure occurred at 1.25mm/sec. Cyclic displacement, structural stiffness, and ultimate load were derived from resultant load-displacement curves. Student t-tests were used to evaluate significant effects between both FHL tendon transfer techniques. Linear regression analysis was performed to assess interactions between bone density and strength of FHL tendon transfer. Results: Average tendon diameter of the 24 FHL samples was 5.44+-0.46 mm. Average bone density for all 24 calcaneus samples was determined to be 1.06+-0.08 g/cm 2 . Loading data was normalized with respect to bone density and tendon diameter to account for inherent anatomical differences between cadaveric specimens. The addition of a cortical button for FHL transfer to the calcaneus did not significantly affect cyclic displacement (0.78+-0.52mm vs 0.87+-0.80mm) or structural stiffness (162.11+- 43.34N/mm vs. 167.57+-49.19N/mm). Addition of the cortical button to the FHL tendon transfer construct resulted in a 34% significant increase in ultimate load (343.72+-68.93 N) compared to biotenodesis screw alone (255.62+-77.17 N) (p=0.0002). Linear regression analyses did not reveal any significant interactions between bone density and FHL tendon transfer technique. Conclusion: Enhanced strength can be achieved for Achilles pathology repaired with FHL tendon transfer utilizing a biotenodesis screw and cortical button tension slide technique demonstrated by a statistically significant 34% increase in ultimate load, subsequent to cyclic loading. Cortical buttons in the setting of FHL tendon transfer to the calcaneus offers an additional level of support in the case of extreme tendon transfer failure.https://doi.org/10.1177/2473011421S00374
spellingShingle Kaitlin C. Neary MD
Sarah J. McClish
Anthony N. Khoury
Nick Denove
Coen A. Wijdicks
Single Biotenodesis Screw vs Biotenodesis Screw with Cortical Button Tension Slide Technique for Flexor Hallucis Longus Transfer: A Biomechanical Analysis
Foot & Ankle Orthopaedics
title Single Biotenodesis Screw vs Biotenodesis Screw with Cortical Button Tension Slide Technique for Flexor Hallucis Longus Transfer: A Biomechanical Analysis
title_full Single Biotenodesis Screw vs Biotenodesis Screw with Cortical Button Tension Slide Technique for Flexor Hallucis Longus Transfer: A Biomechanical Analysis
title_fullStr Single Biotenodesis Screw vs Biotenodesis Screw with Cortical Button Tension Slide Technique for Flexor Hallucis Longus Transfer: A Biomechanical Analysis
title_full_unstemmed Single Biotenodesis Screw vs Biotenodesis Screw with Cortical Button Tension Slide Technique for Flexor Hallucis Longus Transfer: A Biomechanical Analysis
title_short Single Biotenodesis Screw vs Biotenodesis Screw with Cortical Button Tension Slide Technique for Flexor Hallucis Longus Transfer: A Biomechanical Analysis
title_sort single biotenodesis screw vs biotenodesis screw with cortical button tension slide technique for flexor hallucis longus transfer a biomechanical analysis
url https://doi.org/10.1177/2473011421S00374
work_keys_str_mv AT kaitlincnearymd singlebiotenodesisscrewvsbiotenodesisscrewwithcorticalbuttontensionslidetechniqueforflexorhallucislongustransferabiomechanicalanalysis
AT sarahjmcclish singlebiotenodesisscrewvsbiotenodesisscrewwithcorticalbuttontensionslidetechniqueforflexorhallucislongustransferabiomechanicalanalysis
AT anthonynkhoury singlebiotenodesisscrewvsbiotenodesisscrewwithcorticalbuttontensionslidetechniqueforflexorhallucislongustransferabiomechanicalanalysis
AT nickdenove singlebiotenodesisscrewvsbiotenodesisscrewwithcorticalbuttontensionslidetechniqueforflexorhallucislongustransferabiomechanicalanalysis
AT coenawijdicks singlebiotenodesisscrewvsbiotenodesisscrewwithcorticalbuttontensionslidetechniqueforflexorhallucislongustransferabiomechanicalanalysis