EVALUATION OF SUITABILITY FACILITIES FOR ACTIVE FIRE PROTECTION IN PT DOK DAN PERKAPALAN SURABAYA (PERSERO)

Background: Every shipyard has a fire hazard that needs to have a sufficient fire protection. PT. Dok dan Perkapalan Surabaya (Persero) has the potential for fire do to hot work and usage of high vultage electricity. Active fire protection facilities at PT. Dok dan Perkapalan Surabaya (Persero) need...

Full description

Bibliographic Details
Main Authors: Anisa Karyati, Erwin Dyah Nawawiwetu
Format: Article
Language:Indonesian
Published: Universitas Airlangga 2020-03-01
Series:Journal of Vocational Health Studies
Subjects:
Online Access:https://e-journal.unair.ac.id/JVHS/article/view/19341
_version_ 1818980790810181632
author Anisa Karyati
Erwin Dyah Nawawiwetu
author_facet Anisa Karyati
Erwin Dyah Nawawiwetu
author_sort Anisa Karyati
collection DOAJ
description Background: Every shipyard has a fire hazard that needs to have a sufficient fire protection. PT. Dok dan Perkapalan Surabaya (Persero) has the potential for fire do to hot work and usage of high vultage electricity. Active fire protection facilities at PT. Dok dan Perkapalan Surabaya (Persero) need to be evaluated to ensure that the active fire protection facilities are always in good condition. Purpose: The purpose of this research was to evaluate the application of active protection means in PT. Dok dan Perkapalan Surabaya (Persero) to comply with the rule and standard namely : Permenakertrans No. Per 04/MEN/1980 for fire extinguisher, Permen PU No. 26/PRT/M/2008 and SNI 03-1745-2000 for hydrant. Method: This research was observational descriptive one. The object of this research were : fire extinguisher and hydrant in PT. Dok dan Perkapalan Surabaya (Persero). Data collected by questionnaire,checklist, and observation. Result: The result showed that the active protective means for fire extinguisher in good category with a level of suitability of 92,9% and for hydrant in sufficient condition with a level of suitability of 73,5%. Conclusion:. There were some elements that were not suitable, such as some fire extinguisher covered by items, some fire extinguisher installations exceed 120 cm from the floor surface, some fire extinguisher were defective due to rusting, there were no hydrant use instructions, and no fire hydrant have been examined. PT. Dok dan Perkapalan Surabaya (Persero) is suggested to move items that cover fire extinguisher to be easily seen, the height of the fire extinguisher installation should not exceed 120 cm from Permenakertrans No. Per 04/MEN/1980, replacing inappropriate fire extinguisher, carrying out rountine fire check.
first_indexed 2024-12-20T17:21:02Z
format Article
id doaj.art-ebf12a0ed7c046ba8ea655715a32a4c3
institution Directory Open Access Journal
issn 2580-7161
2580-717X
language Indonesian
last_indexed 2024-12-20T17:21:02Z
publishDate 2020-03-01
publisher Universitas Airlangga
record_format Article
series Journal of Vocational Health Studies
spelling doaj.art-ebf12a0ed7c046ba8ea655715a32a4c32022-12-21T19:31:50ZindUniversitas AirlanggaJournal of Vocational Health Studies2580-71612580-717X2020-03-013313113510.20473/jvhs.V3.I3.2020.131-1359244EVALUATION OF SUITABILITY FACILITIES FOR ACTIVE FIRE PROTECTION IN PT DOK DAN PERKAPALAN SURABAYA (PERSERO)Anisa Karyati0Erwin Dyah Nawawiwetu1Universitas Airlangga, Surabaya-Indonesiaerwindyah2012@gmail.comBackground: Every shipyard has a fire hazard that needs to have a sufficient fire protection. PT. Dok dan Perkapalan Surabaya (Persero) has the potential for fire do to hot work and usage of high vultage electricity. Active fire protection facilities at PT. Dok dan Perkapalan Surabaya (Persero) need to be evaluated to ensure that the active fire protection facilities are always in good condition. Purpose: The purpose of this research was to evaluate the application of active protection means in PT. Dok dan Perkapalan Surabaya (Persero) to comply with the rule and standard namely : Permenakertrans No. Per 04/MEN/1980 for fire extinguisher, Permen PU No. 26/PRT/M/2008 and SNI 03-1745-2000 for hydrant. Method: This research was observational descriptive one. The object of this research were : fire extinguisher and hydrant in PT. Dok dan Perkapalan Surabaya (Persero). Data collected by questionnaire,checklist, and observation. Result: The result showed that the active protective means for fire extinguisher in good category with a level of suitability of 92,9% and for hydrant in sufficient condition with a level of suitability of 73,5%. Conclusion:. There were some elements that were not suitable, such as some fire extinguisher covered by items, some fire extinguisher installations exceed 120 cm from the floor surface, some fire extinguisher were defective due to rusting, there were no hydrant use instructions, and no fire hydrant have been examined. PT. Dok dan Perkapalan Surabaya (Persero) is suggested to move items that cover fire extinguisher to be easily seen, the height of the fire extinguisher installation should not exceed 120 cm from Permenakertrans No. Per 04/MEN/1980, replacing inappropriate fire extinguisher, carrying out rountine fire check.https://e-journal.unair.ac.id/JVHS/article/view/19341active fire protectionfire extinguisherhydrant
spellingShingle Anisa Karyati
Erwin Dyah Nawawiwetu
EVALUATION OF SUITABILITY FACILITIES FOR ACTIVE FIRE PROTECTION IN PT DOK DAN PERKAPALAN SURABAYA (PERSERO)
Journal of Vocational Health Studies
active fire protection
fire extinguisher
hydrant
title EVALUATION OF SUITABILITY FACILITIES FOR ACTIVE FIRE PROTECTION IN PT DOK DAN PERKAPALAN SURABAYA (PERSERO)
title_full EVALUATION OF SUITABILITY FACILITIES FOR ACTIVE FIRE PROTECTION IN PT DOK DAN PERKAPALAN SURABAYA (PERSERO)
title_fullStr EVALUATION OF SUITABILITY FACILITIES FOR ACTIVE FIRE PROTECTION IN PT DOK DAN PERKAPALAN SURABAYA (PERSERO)
title_full_unstemmed EVALUATION OF SUITABILITY FACILITIES FOR ACTIVE FIRE PROTECTION IN PT DOK DAN PERKAPALAN SURABAYA (PERSERO)
title_short EVALUATION OF SUITABILITY FACILITIES FOR ACTIVE FIRE PROTECTION IN PT DOK DAN PERKAPALAN SURABAYA (PERSERO)
title_sort evaluation of suitability facilities for active fire protection in pt dok dan perkapalan surabaya persero
topic active fire protection
fire extinguisher
hydrant
url https://e-journal.unair.ac.id/JVHS/article/view/19341
work_keys_str_mv AT anisakaryati evaluationofsuitabilityfacilitiesforactivefireprotectioninptdokdanperkapalansurabayapersero
AT erwindyahnawawiwetu evaluationofsuitabilityfacilitiesforactivefireprotectioninptdokdanperkapalansurabayapersero