DEPLOYMENT OF SIX SIGMA METHODOLOGY IN PHACOEMULSIFICATION CATARACT SURGERY

The purpose of this study is to show how a public eye care center in Turkey initiated Six Sigma principles to reduce the number of complications encountered during and after phacoemulsification cataract surgeries. To analyze the 3-year data, main tools of Six Sigma’s Define-Measure-Analyze-Improve-C...

Full description

Bibliographic Details
Main Authors: Ibrahim SAHBAZ, Mehmet Tolga TANER, Gamze KAGAN, Hüseyin SANISOGLU, Engin ERBAS, Ebubekir DURMUS, Meltem TUNCA, Hazar ENGINYURT
Format: Article
Language:English
Published: EconJournals 2014-04-01
Series:International Review of Management and Marketing
Online Access:http://www.econjournals.com/index.php/irmm/article/view/778/pdf
_version_ 1797915266440495104
author Ibrahim SAHBAZ
Mehmet Tolga TANER
Gamze KAGAN
Hüseyin SANISOGLU
Engin ERBAS
Ebubekir DURMUS
Meltem TUNCA
Hazar ENGINYURT
author_facet Ibrahim SAHBAZ
Mehmet Tolga TANER
Gamze KAGAN
Hüseyin SANISOGLU
Engin ERBAS
Ebubekir DURMUS
Meltem TUNCA
Hazar ENGINYURT
author_sort Ibrahim SAHBAZ
collection DOAJ
description The purpose of this study is to show how a public eye care center in Turkey initiated Six Sigma principles to reduce the number of complications encountered during and after phacoemulsification cataract surgeries. To analyze the 3-year data, main tools of Six Sigma’s Define-Measure-Analyze-Improve-Control (DMAIC) improvement cycle such as SIPOC table, Fishbone Diagram and, Failure, Mode and Effect Analysis were implemented. Experience of the ophthalmic surgeon, patient’s anatomy, cooperation of patient during the surgery, sterilization and hygiene, attention of assistant surgeon, calibration of equipment and quality/chemical composition of intraocular material were identified to be Critical-to-Quality (CTQ) factors for a successful phacoemulsification cataract surgery. The most frequently occurring complication was found to be iris atrophy. The process sigma level for the process was found to be 3.958.
first_indexed 2024-04-10T12:39:01Z
format Article
id doaj.art-ec40ff33bb0b44fd90164ada0cd77ca8
institution Directory Open Access Journal
issn 2146-4405
2146-4405
language English
last_indexed 2024-04-10T12:39:01Z
publishDate 2014-04-01
publisher EconJournals
record_format Article
series International Review of Management and Marketing
spelling doaj.art-ec40ff33bb0b44fd90164ada0cd77ca82023-02-15T16:14:27ZengEconJournalsInternational Review of Management and Marketing2146-44052146-44052014-04-0142123131DEPLOYMENT OF SIX SIGMA METHODOLOGY IN PHACOEMULSIFICATION CATARACT SURGERYIbrahim SAHBAZMehmet Tolga TANERGamze KAGANHüseyin SANISOGLU Engin ERBASEbubekir DURMUSMeltem TUNCAHazar ENGINYURTThe purpose of this study is to show how a public eye care center in Turkey initiated Six Sigma principles to reduce the number of complications encountered during and after phacoemulsification cataract surgeries. To analyze the 3-year data, main tools of Six Sigma’s Define-Measure-Analyze-Improve-Control (DMAIC) improvement cycle such as SIPOC table, Fishbone Diagram and, Failure, Mode and Effect Analysis were implemented. Experience of the ophthalmic surgeon, patient’s anatomy, cooperation of patient during the surgery, sterilization and hygiene, attention of assistant surgeon, calibration of equipment and quality/chemical composition of intraocular material were identified to be Critical-to-Quality (CTQ) factors for a successful phacoemulsification cataract surgery. The most frequently occurring complication was found to be iris atrophy. The process sigma level for the process was found to be 3.958.http://www.econjournals.com/index.php/irmm/article/view/778/pdf
spellingShingle Ibrahim SAHBAZ
Mehmet Tolga TANER
Gamze KAGAN
Hüseyin SANISOGLU
Engin ERBAS
Ebubekir DURMUS
Meltem TUNCA
Hazar ENGINYURT
DEPLOYMENT OF SIX SIGMA METHODOLOGY IN PHACOEMULSIFICATION CATARACT SURGERY
International Review of Management and Marketing
title DEPLOYMENT OF SIX SIGMA METHODOLOGY IN PHACOEMULSIFICATION CATARACT SURGERY
title_full DEPLOYMENT OF SIX SIGMA METHODOLOGY IN PHACOEMULSIFICATION CATARACT SURGERY
title_fullStr DEPLOYMENT OF SIX SIGMA METHODOLOGY IN PHACOEMULSIFICATION CATARACT SURGERY
title_full_unstemmed DEPLOYMENT OF SIX SIGMA METHODOLOGY IN PHACOEMULSIFICATION CATARACT SURGERY
title_short DEPLOYMENT OF SIX SIGMA METHODOLOGY IN PHACOEMULSIFICATION CATARACT SURGERY
title_sort deployment of six sigma methodology in phacoemulsification cataract surgery
url http://www.econjournals.com/index.php/irmm/article/view/778/pdf
work_keys_str_mv AT ibrahimsahbaz deploymentofsixsigmamethodologyinphacoemulsificationcataractsurgery
AT mehmettolgataner deploymentofsixsigmamethodologyinphacoemulsificationcataractsurgery
AT gamzekagan deploymentofsixsigmamethodologyinphacoemulsificationcataractsurgery
AT huseyinsanisoglu deploymentofsixsigmamethodologyinphacoemulsificationcataractsurgery
AT enginerbas deploymentofsixsigmamethodologyinphacoemulsificationcataractsurgery
AT ebubekirdurmus deploymentofsixsigmamethodologyinphacoemulsificationcataractsurgery
AT meltemtunca deploymentofsixsigmamethodologyinphacoemulsificationcataractsurgery
AT hazarenginyurt deploymentofsixsigmamethodologyinphacoemulsificationcataractsurgery