Tenant-based measured electricity use in 4 large office buildings in Tallinn, Estonia

The energy performance assessment of buildings during design is usually based on energy simulations with pre-defined input data from standards and legislations. Typically, the internal gain values and profiles are based on EN 16798–1. However, studies have shown that the real electricity use of plug...

Full description

Bibliographic Details
Main Authors: Ferrantelli Andrea, Aljas Hans Kristjan, Maask Vahur, Thalfeldt Martin
Format: Article
Language:English
Published: EDP Sciences 2021-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/22/e3sconf_hvac2021_04001.pdf
_version_ 1818591613177298944
author Ferrantelli Andrea
Aljas Hans Kristjan
Maask Vahur
Thalfeldt Martin
author_facet Ferrantelli Andrea
Aljas Hans Kristjan
Maask Vahur
Thalfeldt Martin
author_sort Ferrantelli Andrea
collection DOAJ
description The energy performance assessment of buildings during design is usually based on energy simulations with pre-defined input data from standards and legislations. Typically, the internal gain values and profiles are based on EN 16798–1. However, studies have shown that the real electricity use of plug load and lighting varies more smoothly than in the profiles of EN 16798–1 where zero occupancy outside working hours is assumed. This might result in sub-optimal building solutions due to inadequate building performance simulation input data. The aim of this work is to structure and analyse data from a total of 196 electricity meters in 4 large office buildings in Tallinn, Estonia. Typically, 3 to 8 electricity meters were installed per floor with the consumption coming mainly from plug loads and electric lighting. The data had been gathered between the years 2016–2020 with either 1 or 24 hour time steps, depending on the building and the electricity meter. 3 out of the 4 buildings had an average normalized energy usage slightly below the modelling value calculated according to EN16798–1. Some office spaces stood out with an abnormally high electricity consumption, however, the 24-hour distributions were fairly compact, meaning quite steady consumption patterns. When looking at the dispersion of energy consumption per 24h, averaged over all given offices in a building, no outliers stood out, either. This means that there are not many days when the average consumption and internal heat gains of all offices were simultaneously well below the mean. Additionally, major events like holidays and the COVID19-induced lockdown show up well on the graphs, but also planned changes in occupancy can be seen.
first_indexed 2024-12-16T10:15:13Z
format Article
id doaj.art-ec7423766ac0459a9b6bc5d963087c7d
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-12-16T10:15:13Z
publishDate 2021-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-ec7423766ac0459a9b6bc5d963087c7d2022-12-21T22:35:29ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012460400110.1051/e3sconf/202124604001e3sconf_hvac2021_04001Tenant-based measured electricity use in 4 large office buildings in Tallinn, EstoniaFerrantelli Andrea0Aljas Hans Kristjan1Maask Vahur2Thalfeldt MartinDepartment of Civil Engineering and Architecture, Tallinn University of TechnologyDepartment of Civil Engineering and Architecture, Tallinn University of TechnologyDepartment of Electrical Power Engineering and Mechatronics, Tallinn University of TechnologyThe energy performance assessment of buildings during design is usually based on energy simulations with pre-defined input data from standards and legislations. Typically, the internal gain values and profiles are based on EN 16798–1. However, studies have shown that the real electricity use of plug load and lighting varies more smoothly than in the profiles of EN 16798–1 where zero occupancy outside working hours is assumed. This might result in sub-optimal building solutions due to inadequate building performance simulation input data. The aim of this work is to structure and analyse data from a total of 196 electricity meters in 4 large office buildings in Tallinn, Estonia. Typically, 3 to 8 electricity meters were installed per floor with the consumption coming mainly from plug loads and electric lighting. The data had been gathered between the years 2016–2020 with either 1 or 24 hour time steps, depending on the building and the electricity meter. 3 out of the 4 buildings had an average normalized energy usage slightly below the modelling value calculated according to EN16798–1. Some office spaces stood out with an abnormally high electricity consumption, however, the 24-hour distributions were fairly compact, meaning quite steady consumption patterns. When looking at the dispersion of energy consumption per 24h, averaged over all given offices in a building, no outliers stood out, either. This means that there are not many days when the average consumption and internal heat gains of all offices were simultaneously well below the mean. Additionally, major events like holidays and the COVID19-induced lockdown show up well on the graphs, but also planned changes in occupancy can be seen.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/22/e3sconf_hvac2021_04001.pdf
spellingShingle Ferrantelli Andrea
Aljas Hans Kristjan
Maask Vahur
Thalfeldt Martin
Tenant-based measured electricity use in 4 large office buildings in Tallinn, Estonia
E3S Web of Conferences
title Tenant-based measured electricity use in 4 large office buildings in Tallinn, Estonia
title_full Tenant-based measured electricity use in 4 large office buildings in Tallinn, Estonia
title_fullStr Tenant-based measured electricity use in 4 large office buildings in Tallinn, Estonia
title_full_unstemmed Tenant-based measured electricity use in 4 large office buildings in Tallinn, Estonia
title_short Tenant-based measured electricity use in 4 large office buildings in Tallinn, Estonia
title_sort tenant based measured electricity use in 4 large office buildings in tallinn estonia
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/22/e3sconf_hvac2021_04001.pdf
work_keys_str_mv AT ferrantelliandrea tenantbasedmeasuredelectricityusein4largeofficebuildingsintallinnestonia
AT aljashanskristjan tenantbasedmeasuredelectricityusein4largeofficebuildingsintallinnestonia
AT maaskvahur tenantbasedmeasuredelectricityusein4largeofficebuildingsintallinnestonia
AT thalfeldtmartin tenantbasedmeasuredelectricityusein4largeofficebuildingsintallinnestonia