Variations in the full blood count parameters among apparently healthy humans in the Ho municipality using ethylenediamine tetraacetic acid (EDTA), sodium citrate and lithium heparin anticoagulants: A laboratory-based cross-sectional analytical study

Background: Several studies have shown that various anticoagulants used for collection of blood samples produce varying effects on haematological analyses. Tripotassium ethylenediamine tetra-acetic acid (K3EDTA), sodium citrate and lithium heparin remain the most used anticoagulants employed in hema...

Full description

Bibliographic Details
Main Authors: Elliot Elikplim Akorsu, Linda Brown Adjabeng, Maridiatu Amir Sulleymana, Precious Kwablah Kwadzokpui
Format: Article
Language:English
Published: Elsevier 2023-06-01
Series:Heliyon
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S240584402304519X
_version_ 1797802208229588992
author Elliot Elikplim Akorsu
Linda Brown Adjabeng
Maridiatu Amir Sulleymana
Precious Kwablah Kwadzokpui
author_facet Elliot Elikplim Akorsu
Linda Brown Adjabeng
Maridiatu Amir Sulleymana
Precious Kwablah Kwadzokpui
author_sort Elliot Elikplim Akorsu
collection DOAJ
description Background: Several studies have shown that various anticoagulants used for collection of blood samples produce varying effects on haematological analyses. Tripotassium ethylenediamine tetra-acetic acid (K3EDTA), sodium citrate and lithium heparin remain the most used anticoagulants employed in hematological analysis. There is paucity of data on the effect of these anticoagulants on haematological parameters in humans in Ghana. We assessed the suitability of K3EDTA, sodium citrate and lithium heparin for routine Full Blood Count (FBC) investigation. Method: A laboratory-based analytical cross-sectional study was conducted using blood samples from 55 conveniently sampled apparently healthy tertiary students from January 2021 to October 2021. Blood samples were taken from each participant into 3 anticoagulant tubes: K3EDTA, sodium citrate and lithium heparin and FBC parameters estimated using the Mindray automated haematology analyzer. One-way ANOVA Kruskal-Wallis test, Mann-Whitney U, Intra-class correlation coefficient (ICC) analysis, Bland-Altman's plot and Lin's concordance correlation coefficient were used where appropriate to ascertain the level of variation, consistency, and agreements among and between results. Normality testing using Shapiro-Wilk test statistic revealed non-Gaussian distribution of data, hence, were presented as median, minimum, and maximum. Data generated were analyzed using STATA v15 and MedCalc v20 where appropriate for statistical analysis. P-values <0.05 were considered statistically significant. Results: The study comprised 34 males and 21 females. The median age for males (23 years: min = 20, max = 34) was statistically comparable (p = 0.2652) to that of females (22 years: min = 18, max = 34). We observed excellent consistency in the estimation of MCV (ICC = 0.94), MCH (ICC = 0.98), MCHC (ICC = 0.91), GRAN# (ICC = 0.92) and LYMPH% (ICC = 0.91) across the three anticoagulants. Heparin and K3EDTA largely agreed on most of the FBC parameters, 50.0% (7/14) including HGB, MCV, MCH, PLT, LYMPH#, GRAN# and GRAN%. Meanwhile using K3EDTA as a standard, heparin produced almost perfect agreement only in the assessment of RBC (CCC = 0.992) while a substantial agreement was observed in the assessment of HGB (0.971), HCT (0.958) and MCH (0.987). Citrate agreed substantially with K3EDTA in the assessment of LYMPH% (CCC = 0.964) and moderately in the assessment of MCV (CCC = 0.948) and MCH (0.913). Overall, compared to K3EDTA, heparin was highly precise and accurate in the estimation of HGB, RBC, HCT and MCH while citrate determined MCV and MCH more accurately and precisely. Conclusion: Citrated blood consistently produced lower FBC values compared to heparin and K3EDTA and hence suggests not reliable in the assessment of FBC among humans. Heparin agreed largely with K3EDTA in the estimation of FBC parameters and may be used as a better alternative anticoagulant in the absence of K3EDTA however with great caution.
first_indexed 2024-03-13T05:02:15Z
format Article
id doaj.art-ec94ac0f575d4c4eb2e1a6197b74b297
institution Directory Open Access Journal
issn 2405-8440
language English
last_indexed 2024-03-13T05:02:15Z
publishDate 2023-06-01
publisher Elsevier
record_format Article
series Heliyon
spelling doaj.art-ec94ac0f575d4c4eb2e1a6197b74b2972023-06-17T05:19:36ZengElsevierHeliyon2405-84402023-06-0196e17311Variations in the full blood count parameters among apparently healthy humans in the Ho municipality using ethylenediamine tetraacetic acid (EDTA), sodium citrate and lithium heparin anticoagulants: A laboratory-based cross-sectional analytical studyElliot Elikplim Akorsu0Linda Brown Adjabeng1Maridiatu Amir Sulleymana2Precious Kwablah Kwadzokpui3Department of Medical Laboratory Science, School of Allied Health Sciences, University of Health and Allied Sciences, Ho, GhanaDepartment of Medical Laboratory Science, School of Allied Health Sciences, University of Health and Allied Sciences, Ho, GhanaDepartment of Medical Laboratory Science, School of Allied Health Sciences, University of Health and Allied Sciences, Ho, GhanaDepartment of Medical Laboratory Science, School of Allied Health Sciences, University of Health and Allied Sciences, Ho, Ghana; The Laboratory Department, Ho Teaching Hospital, Ho, Ghana; Corresponding author. The Laboratory Department, Ho Teaching Hospital, Ho, Ghana.Background: Several studies have shown that various anticoagulants used for collection of blood samples produce varying effects on haematological analyses. Tripotassium ethylenediamine tetra-acetic acid (K3EDTA), sodium citrate and lithium heparin remain the most used anticoagulants employed in hematological analysis. There is paucity of data on the effect of these anticoagulants on haematological parameters in humans in Ghana. We assessed the suitability of K3EDTA, sodium citrate and lithium heparin for routine Full Blood Count (FBC) investigation. Method: A laboratory-based analytical cross-sectional study was conducted using blood samples from 55 conveniently sampled apparently healthy tertiary students from January 2021 to October 2021. Blood samples were taken from each participant into 3 anticoagulant tubes: K3EDTA, sodium citrate and lithium heparin and FBC parameters estimated using the Mindray automated haematology analyzer. One-way ANOVA Kruskal-Wallis test, Mann-Whitney U, Intra-class correlation coefficient (ICC) analysis, Bland-Altman's plot and Lin's concordance correlation coefficient were used where appropriate to ascertain the level of variation, consistency, and agreements among and between results. Normality testing using Shapiro-Wilk test statistic revealed non-Gaussian distribution of data, hence, were presented as median, minimum, and maximum. Data generated were analyzed using STATA v15 and MedCalc v20 where appropriate for statistical analysis. P-values <0.05 were considered statistically significant. Results: The study comprised 34 males and 21 females. The median age for males (23 years: min = 20, max = 34) was statistically comparable (p = 0.2652) to that of females (22 years: min = 18, max = 34). We observed excellent consistency in the estimation of MCV (ICC = 0.94), MCH (ICC = 0.98), MCHC (ICC = 0.91), GRAN# (ICC = 0.92) and LYMPH% (ICC = 0.91) across the three anticoagulants. Heparin and K3EDTA largely agreed on most of the FBC parameters, 50.0% (7/14) including HGB, MCV, MCH, PLT, LYMPH#, GRAN# and GRAN%. Meanwhile using K3EDTA as a standard, heparin produced almost perfect agreement only in the assessment of RBC (CCC = 0.992) while a substantial agreement was observed in the assessment of HGB (0.971), HCT (0.958) and MCH (0.987). Citrate agreed substantially with K3EDTA in the assessment of LYMPH% (CCC = 0.964) and moderately in the assessment of MCV (CCC = 0.948) and MCH (0.913). Overall, compared to K3EDTA, heparin was highly precise and accurate in the estimation of HGB, RBC, HCT and MCH while citrate determined MCV and MCH more accurately and precisely. Conclusion: Citrated blood consistently produced lower FBC values compared to heparin and K3EDTA and hence suggests not reliable in the assessment of FBC among humans. Heparin agreed largely with K3EDTA in the estimation of FBC parameters and may be used as a better alternative anticoagulant in the absence of K3EDTA however with great caution.http://www.sciencedirect.com/science/article/pii/S240584402304519XFull blood fountAnticoagulantHaematologicalSodium citrateLithium heparinEthylenediamine tetra-acetic acid
spellingShingle Elliot Elikplim Akorsu
Linda Brown Adjabeng
Maridiatu Amir Sulleymana
Precious Kwablah Kwadzokpui
Variations in the full blood count parameters among apparently healthy humans in the Ho municipality using ethylenediamine tetraacetic acid (EDTA), sodium citrate and lithium heparin anticoagulants: A laboratory-based cross-sectional analytical study
Heliyon
Full blood fount
Anticoagulant
Haematological
Sodium citrate
Lithium heparin
Ethylenediamine tetra-acetic acid
title Variations in the full blood count parameters among apparently healthy humans in the Ho municipality using ethylenediamine tetraacetic acid (EDTA), sodium citrate and lithium heparin anticoagulants: A laboratory-based cross-sectional analytical study
title_full Variations in the full blood count parameters among apparently healthy humans in the Ho municipality using ethylenediamine tetraacetic acid (EDTA), sodium citrate and lithium heparin anticoagulants: A laboratory-based cross-sectional analytical study
title_fullStr Variations in the full blood count parameters among apparently healthy humans in the Ho municipality using ethylenediamine tetraacetic acid (EDTA), sodium citrate and lithium heparin anticoagulants: A laboratory-based cross-sectional analytical study
title_full_unstemmed Variations in the full blood count parameters among apparently healthy humans in the Ho municipality using ethylenediamine tetraacetic acid (EDTA), sodium citrate and lithium heparin anticoagulants: A laboratory-based cross-sectional analytical study
title_short Variations in the full blood count parameters among apparently healthy humans in the Ho municipality using ethylenediamine tetraacetic acid (EDTA), sodium citrate and lithium heparin anticoagulants: A laboratory-based cross-sectional analytical study
title_sort variations in the full blood count parameters among apparently healthy humans in the ho municipality using ethylenediamine tetraacetic acid edta sodium citrate and lithium heparin anticoagulants a laboratory based cross sectional analytical study
topic Full blood fount
Anticoagulant
Haematological
Sodium citrate
Lithium heparin
Ethylenediamine tetra-acetic acid
url http://www.sciencedirect.com/science/article/pii/S240584402304519X
work_keys_str_mv AT elliotelikplimakorsu variationsinthefullbloodcountparametersamongapparentlyhealthyhumansinthehomunicipalityusingethylenediaminetetraaceticacidedtasodiumcitrateandlithiumheparinanticoagulantsalaboratorybasedcrosssectionalanalyticalstudy
AT lindabrownadjabeng variationsinthefullbloodcountparametersamongapparentlyhealthyhumansinthehomunicipalityusingethylenediaminetetraaceticacidedtasodiumcitrateandlithiumheparinanticoagulantsalaboratorybasedcrosssectionalanalyticalstudy
AT maridiatuamirsulleymana variationsinthefullbloodcountparametersamongapparentlyhealthyhumansinthehomunicipalityusingethylenediaminetetraaceticacidedtasodiumcitrateandlithiumheparinanticoagulantsalaboratorybasedcrosssectionalanalyticalstudy
AT preciouskwablahkwadzokpui variationsinthefullbloodcountparametersamongapparentlyhealthyhumansinthehomunicipalityusingethylenediaminetetraaceticacidedtasodiumcitrateandlithiumheparinanticoagulantsalaboratorybasedcrosssectionalanalyticalstudy