Study on joint detection of fabricated concrete shear wall based on percussion method

The knock detection method is one of the non-destructive testing methods for assembly prefabricated components. The knocker is used to knock on the concrete prefabricated components to be tested. The internal conditions of the tested components can be judged by analyzing the time-domain and frequenc...

Full description

Bibliographic Details
Main Authors: Song Bo, Li Jian, Wang Man sheng
Format: Article
Language:English
Published: EDP Sciences 2019-01-01
Series:MATEC Web of Conferences
Online Access:https://www.matec-conferences.org/articles/matecconf/pdf/2019/26/matecconf_jcmme2018_03019.pdf
Description
Summary:The knock detection method is one of the non-destructive testing methods for assembly prefabricated components. The knocker is used to knock on the concrete prefabricated components to be tested. The internal conditions of the tested components can be judged by analyzing the time-domain and frequency-domain diagrams of the knocker. In this paper, the impact of the change of the knock point on the detection is studied by using the knock detection experiment. It is found that the location of the knock point has a great influence on the detection. With the change of the position of the knock point, the peak frequency in the spectrum obtained by the detection changes correspondingly. According to the frequency information corresponding to the peak value in the spectrum, the depth of the void to the knock surface can be calculated.
ISSN:2261-236X